Skip to main content
QUICK REVIEW

[Paper Review] Valid P-Value for Deep Learning-Driven Salient Region

Daiki Miwa, Vo Nguyen Le Duy|arXiv (Cornell University)|Jan 6, 2023
Explainable Artificial Intelligence (XAI)Computer Science3 citations
TL;DR

This paper proposes a selective inference framework to compute valid p-values for saliency maps in deep learning, correcting for selection bias inherent in DNN-driven salient region detection. By modeling the salient region as a data-selected hypothesis and applying conditional inference, the method provably controls Type I error rates, outperforming naive p-values in both synthetic and real-world brain tumor datasets.

ABSTRACT

Various saliency map methods have been proposed to interpret and explain predictions of deep learning models. Saliency maps allow us to interpret which parts of the input signals have a strong influence on the prediction results. However, since a saliency map is obtained by complex computations in deep learning models, it is often difficult to know how reliable the saliency map itself is. In this study, we propose a method to quantify the reliability of a salient region in the form of p-values. Our idea is to consider a salient region as a selected hypothesis by the trained deep learning model and employ the selective inference framework. The proposed method can provably control the probability of false positive detections of salient regions. We demonstrate the validity of the proposed method through numerical examples in synthetic and real datasets. Furthermore, we develop a Keras-based framework for conducting the proposed selective inference for a wide class of CNNs without additional implementation cost.

Motivation & Objective

  • To address the lack of statistical rigor in interpreting deep learning-driven saliency maps, which are often unreliable due to selection bias.
  • To develop a method that quantifies the statistical significance of salient regions using p-values that are provably valid under selection bias.
  • To enable reliable hypothesis testing on salient regions identified by deep neural networks without requiring model retraining or additional implementation cost.
  • To demonstrate the method's effectiveness in controlling false positive rates while maintaining high true positive detection rates on both synthetic and real-world data.

Proposed method

  • The method treats the salient region identified by a trained DNN as a selected hypothesis, enabling statistical inference conditional on the selection event.
  • It employs conditional selective inference (SI) to correct for selection bias by computing the sampling distribution of the test statistic conditional on the salient region being selected.
  • The approach derives exact (non-asymptotic) conditional sampling distributions for salient regions in a wide class of CNNs through recursive propagation of bounds on piecewise linear components.
  • The framework is implemented in Keras, allowing plug-and-play application to various CNN architectures with no additional implementation cost.
  • The method uses two-sample testing between the salient region and a reference region to compute p-values, with significance assessed under the null hypothesis of no signal.
  • It leverages the structure of ReLU-based CNNs to compute tight bounds on activation intervals, enabling efficient and exact inference.

Experimental results

Research questions

  • RQ1Can we compute valid p-values for saliency maps in deep learning models that account for selection bias?
  • RQ2How does the proposed selective inference method compare to naive p-values in controlling false positive detection rates?
  • RQ3Does the method maintain high statistical power (true positive rate) while ensuring Type I error control?
  • RQ4Can the method be efficiently applied to a wide range of CNN architectures without architectural modifications?

Key findings

  • The proposed method successfully controls the false positive rate (FPR) at the nominal level α = 0.05 across both mean and global null tests in synthetic experiments.
  • In contrast, naive p-values consistently produced near-zero values even in the absence of true salient regions, indicating severe Type I error inflation.
  • The proposed method achieved the highest true positive rate (TPR) among all compared methods, outperforming Bonferroni correction and over-conditioning (OC) approaches.
  • On real brain tumor datasets, the naive p-value remained low (e.g., 0.00) even for images without tumors, while the selective p-value correctly indicated non-significance (e.g., 0.78).
  • For images with actual tumors, both naive and selective p-values were small (e.g., 1.92×10⁻⁴), confirming true positive detection with correct statistical inference.
  • The method demonstrated robustness across different input sizes (n = 64 to 4096) and signal strengths (Δ = 1 to 4), maintaining valid inference under varying conditions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.