Skip to main content
QUICK REVIEW

[Paper Review] Variable stars identification in digitized photographic data

K. V. Sokolovsky, D. M. Kolesnikova|arXiv (Cornell University)|May 11, 2016
Astronomical Observations and InstrumentationEngineering1 references4 citations
TL;DR

This study evaluates 18 statistical variability indices for detecting variable stars in digitized photographic lightcurves from the Moscow collection. Using a dataset of 250,000 lightcurves containing 339 known and 316 new variables, it finds that the highest DFT periodogram peak, interquartile range (IQR), median absolute deviation (MAD), and Stetson’s L index are the most effective general-purpose indicators for identifying variable stars in sparsely sampled, error-uncertain photographic data.

ABSTRACT

We identify 339 known and 316 new variable stars of various types among 250000 lightcurves obtained by digitizing 167 30x30cm photographic plates of the Moscow collection. We use these data to conduct a comprehensive test of 18 statistical characteristics (variability indices) in search for the best general-purpose variability detection statistic. We find that the highest peak on the DFT periodogram, interquartile range, median absolute deviation, and Stetson's L index are the most efficient in recovering variable objects from the set of photographic lightcurves used in our test.

Motivation & Objective

  • To identify the most effective general-purpose variability indices for detecting variable stars in digitized photographic data with uncertain photometry and irregular sampling.
  • To assess the performance of 18 statistical indices—spanning scatter-based, correlation-based, and period-search methods—on a large, real-world dataset of photographic lightcurves.
  • To optimize selection thresholds using completeness (C), purity (P), and F1-score to balance true positive recovery and false positive rejection.
  • To provide a benchmark for future automated variable star searches in archival photographic data, especially where measurement errors are poorly known.

Proposed method

  • The study uses 167 photographic plates (1976–1994) from the Moscow collection, digitized and split into 173 overlapping 52′×52′ subfields, each processed with the VaST software to extract 250,000 lightcurves.
  • A comprehensive list of 655 variable stars (339 known, 316 new) was compiled, including eclipsing binaries, RR Lyrae, and periodic/irregular variables, serving as the ground truth.
  • For each variability index, the expected value and standard deviation (σ) were computed as a function of magnitude, and candidate variables were selected using a threshold of nσ above the expected value for n = 0 to 50.
  • Performance was quantified using completeness (C), purity (P), and F1-score (F1 = 2CP/(C+P)), with the optimal nσ threshold selected to maximize F1 for each index.
  • The F1-score, completeness (C_max), and rejection rate (R_F1_max) were computed as median values across all 173 subfields to ensure robustness.
  • Indices were compared based on their maximum F1-score (F1_max), with the best-performing indices recommended for future automated searches.

Experimental results

Research questions

  • RQ1Which variability index performs best in detecting variable stars across diverse lightcurve types in photographic data with uncertain photometry?
  • RQ2How do scatter-based, correlation-based, and period-search indices compare in terms of completeness and purity when applied to sparsely sampled, noisy photographic lightcurves?
  • RQ3To what extent can variability indices recover low-amplitude or irregularly varying stars when measurement errors are poorly known?
  • RQ4What is the optimal threshold (in σ units) for each index to maximize the F1-score in variable star detection?
  • RQ5Can any index fully recover all known variable stars, or are there inherent limitations in certain index types?

Key findings

  • The highest peak on the Discrete Fourier Transform (DFT) periodogram achieved the highest F1-score (0.500), making it the most effective general-purpose variability index in this dataset.
  • The interquartile range (IQR) and median absolute deviation (MAD) both achieved an F1-score of 0.400 and 100% completeness (C_max = 1.000), indicating strong recovery of variable stars with minimal false positives.
  • Stetson’s L index also achieved an F1-score of 0.400, with high purity (P = 0.996) and full completeness, confirming its robustness for variable star detection in photographic data.
  • Correlation-based indices such as I and l1 showed lower F1-scores (0.154 and 0.250, respectively), with reduced completeness (C_max = 0.667), indicating poor recovery of short-timescale or irregular variables.
  • The DFT-based index and IQR were the only indices to achieve both high F1-score and full completeness (C_max = 1.000), suggesting they are most resilient to missing variable stars.
  • Despite high F1-scores, some indices still failed to recover all variables (C_max < 1.000), and false positives persisted due to measurement errors or blending, highlighting the need for visual inspection in automated pipelines.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.