Margalit G. Mitzner, Moinak Bhattacharya|arXiv (Cornell University)|Mar 6, 2026
Retinal Imaging and AnalysisMedicine0 citations
TL;DR

The paper introduces vessel-type–specific external multiplicative attention using tortuosity and density (dropout) maps derived from arteries, veins, and capillaries on OCTA images to improve AMD detection while enhancing interpretability.

ABSTRACT

Age-related macular degeneration (AMD) is characterized by early micro-vascular alterations that can be captured non-invasively using optical coherence tomography angiography (OCTA), yet most deep learning (DL) models rely on global features and fail to exploit clinically meaningful vascular biomarkers. We introduce an external multiplicative attention framework that incorporates vessel-specific tortuosity maps and vasculature dropout maps derived from arteries, veins, and capillaries. These biomarker maps are generated from vessel segmentations and smoothed across multiple spatial scales to highlight coherent patterns of vascular remodeling and capillary rarefaction. Tortuosity reflects abnormalities in vessel geometry linked to impaired auto-regulation, while dropout maps capture localized perfusion deficits that precede structural retinal damage. The maps are fused with the OCTA projection to guide a deep classifier toward physiologically relevant regions. Arterial tortuosity provided the most consistent discriminative value, while capillary dropout maps performed best among density-based variants, especially at larger smoothing scales. Our proposed method offers interpretable insights aligned with known AMD pathophysiology.

Motivation & Objective

  • Motivate early AMD detection using OCTA by leveraging vascular biomarkers beyond global image features.
  • Develop an external attention framework that incorporates vessel-specific tortuosity and dropout maps across arteries, veins, and capillaries.
  • Assess how smoothing scales and vessel type influence discriminative power and interpretability in AMD classification.

Proposed method

  • Compute vessel-type–specific tortuosity heatmaps from artery, vein, and capillary masks using graph-based edge analysis and multiscale Gaussian smoothing.
  • Compute vessel-density (dropout) maps by measuring local sparsity from binarized vessel masks and apply multi-scale Gaussian smoothing to create attention maps.
  • Fuse each tortuosity or density heatmap with the OCTA projection via per-pixel multiplicative weighting before classification with a ResNet-18 backbone.
  • Train OCTA-500-based AMD vs normal classifiers with a two-stage schedule (warmup on head only, then full fine-tuning) using Adam optimization and focal loss.
  • Evaluate external attention variants across vessel types (artery, vein, capillary) and smoothing scales to identify the most informative priors.
Fig. 1 : Overview of the proposed pipeline vessel segmentations are used to generate tortuosity or density heatmaps (multi- $\sigma$ ), which are then separately fused with the full OCTA projection via multiplicative weighting and classified using a ResNet-18 backbone for AMD detection.
Fig. 1 : Overview of the proposed pipeline vessel segmentations are used to generate tortuosity or density heatmaps (multi- $\sigma$ ), which are then separately fused with the full OCTA projection via multiplicative weighting and classified using a ResNet-18 backbone for AMD detection.

Experimental results

Research questions

  • RQ1Can vessel-type–specific tortuosity and density priors improve AMD detection from OCTA images beyond a baseline OCTA-only model?
  • RQ2Which vessel type (arteries, veins, capillaries) and which biomarker (tortuosity vs density) provide the strongest discriminative power for early AMD signatures?
  • RQ3How do different smoothing scales (sigma) affect the performance and interpretability of vessel-based attention in AMD classification?
  • RQ4Do GradCAM visualizations align with known AMD vascular biomarkers when using biomarker-guided attention?
  • RQ5Does the proposed framework maintain competitive accuracy while increasing interpretability through physiologically meaningful priors?

Key findings

  • External attention using arterial tortuosity yields the most consistent discriminative value among tortuosity maps.
  • Capillary dropout (low-density) maps perform best among density-based variants, especially at larger smoothing scales.
  • Arterial tortuosity attention tends to improve or stabilize performance as the smoothing scale increases, reflecting broader tortuosity patterns.
  • Capillary density-based attention highlights FAZ-related regions and parafoveal nonperfusion consistent with early AMD pathology.
  • GradCAM visualizations show model focus on reduced capillary density, FAZ alterations, and arteriolar tortuosity consistent with AMD biology.
Fig. 2 : Attention heatmaps. Segmentation labels, tortuosity dot maps showing relative tortuosity of each segment, high tortuosity (red hotspots indicate high tortuosity) and low vessel density heatmaps (red hotspots indicate low density).
Fig. 2 : Attention heatmaps. Segmentation labels, tortuosity dot maps showing relative tortuosity of each segment, high tortuosity (red hotspots indicate high tortuosity) and low vessel density heatmaps (red hotspots indicate low density).

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.