Skip to main content
QUICK REVIEW

[Paper Review] Video-based Remote Physiological Measurement via Cross-verified Feature Disentangling

Xuesong Niu, Zitong Yu|arXiv (Cornell University)|Jul 16, 2020
Non-Invasive Vital Sign MonitoringEngineering23 references11 citations
TL;DR

This paper proposes a cross-verified feature disentangling (CVD) method for robust video-based remote physiological measurement, using multi-scale spatial-temporal maps (MSTmaps) to enhance physiological signal representation and an autoencoder with dual encoders to disentangle physiological from non-physiological features via cross-generation. The approach achieves state-of-the-art performance, reducing HR estimation RMSE from 9.03 to 7.97 bpm on public datasets.

ABSTRACT

Remote physiological measurements, e.g., remote photoplethysmography (rPPG) based heart rate (HR), heart rate variability (HRV) and respiration frequency (RF) measuring, are playing more and more important roles under the application scenarios where contact measurement is inconvenient or impossible. Since the amplitude of the physiological signals is very small, they can be easily affected by head movements, lighting conditions, and sensor diversities. To address these challenges, we propose a cross-verified feature disentangling strategy to disentangle the physiological features with non-physiological representations, and then use the distilled physiological features for robust multi-task physiological measurements. We first transform the input face videos into a multi-scale spatial-temporal map (MSTmap), which can suppress the irrelevant background and noise features while retaining most of the temporal characteristics of the periodic physiological signals. Then we take pairwise MSTmaps as inputs to an autoencoder architecture with two encoders (one for physiological signals and the other for non-physiological information) and use a cross-verified scheme to obtain physiological features disentangled with the non-physiological features. The disentangled features are finally used for the joint prediction of multiple physiological signals like average HR values and rPPG signals. Comprehensive experiments on different large-scale public datasets of multiple physiological measurement tasks as well as the cross-database testing demonstrate the robustness of our approach.

Motivation & Objective

  • To address the challenge of non-physiological interference—such as head movements, lighting changes, and sensor noise—in video-based remote physiological measurement.
  • To improve the robustness and accuracy of remote photoplethysmography (rPPG) by disentangling physiological signals from irrelevant video artifacts.
  • To enable joint estimation of average heart rate (HR) and rPPG signals using an end-to-end multi-task learning framework.
  • To develop a data-driven disentanglement strategy that outperforms methods relying on pre-defined non-physiological signals.

Proposed method

  • Transforming input face videos into multi-scale spatial-temporal maps (MSTmaps) to suppress background noise and preserve temporal characteristics of physiological signals.
  • Designing a dual-encoder autoencoder architecture where one encoder extracts physiological features and the other captures non-physiological information.
  • Implementing a cross-verified disentanglement strategy by reconstructing original MSTmaps and cross-generating pseudo-MSTmaps using features from different inputs to enforce feature consistency.
  • Using the disentangled physiological features for joint multi-task prediction of average HR and rPPG signals.
  • Training the network end-to-end with multi-task learning (MTL) to optimize both HR and rPPG estimation simultaneously.
  • Employing batch normalization in encoders and instance normalization in the decoder for stable training and feature reconstruction.

Experimental results

Research questions

  • RQ1Can a data-driven disentanglement strategy effectively separate physiological signals from non-physiological artifacts in video-based rPPG?
  • RQ2Does cross-verified feature disentangling improve the robustness and accuracy of remote physiological measurements under real-world conditions?
  • RQ3How does the proposed CVD method compare to disentanglement using pre-defined non-physiological signals such as head movement and facial pixel variance?
  • RQ4Can the disentangled physiological features be effectively used for multi-task learning of both average HR and rPPG signal estimation?

Key findings

  • The proposed CVD strategy reduces HR estimation RMSE from 9.03 bpm to 7.97 bpm when using MSTmaps as input, representing a significant improvement in accuracy.
  • The method achieves lower MAE (5.02 bpm) and improved correlation (r) compared to baseline methods, demonstrating enhanced robustness.
  • Cross-verified disentangling outperforms disentanglement using pre-defined non-physiological signals such as head movement (N_movement) and facial pixel standard deviation (N_stdface) across all evaluation metrics.
  • The use of MSTmaps as input representation enhances the network’s ability to capture relevant physiological features while suppressing noise and irrelevant variations.
  • The method generalizes well across multiple public datasets and achieves state-of-the-art performance in multi-task remote physiological measurement.
  • The cross-verification mechanism ensures that the physiological encoder focuses exclusively on HR and rPPG-related features, minimizing interference from motion and illumination artifacts.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.