Skip to main content
QUICK REVIEW

[Paper Review] Vision Transformer using Low-level Chest X-ray Feature Corpus for COVID-19 Diagnosis and Severity Quantification

Sang Joon Park, Gwanghyun Kim|arXiv (Cornell University)|Apr 15, 2021
COVID-19 diagnosis using AIMedicine34 references8 citations
TL;DR

This paper proposes a novel Vision Transformer (ViT) framework that leverages pre-trained low-level chest X-ray (CXR) feature embeddings from a large-scale dataset to improve COVID-19 diagnosis and severity quantification. By using a backbone network trained on over 220,000 CXR images to extract common abnormalities (e.g., consolidation, opacity), the model achieves state-of-the-art performance with superior generalization across diverse external datasets, outperforming existing CNN and ViT baselines.

ABSTRACT

Developing a robust algorithm to diagnose and quantify the severity of COVID-19 using Chest X-ray (CXR) requires a large number of well-curated COVID-19 datasets, which is difficult to collect under the global COVID-19 pandemic. On the other hand, CXR data with other findings are abundant. This situation is ideally suited for the Vision Transformer (ViT) architecture, where a lot of unlabeled data can be used through structural modeling by the self-attention mechanism. However, the use of existing ViT is not optimal, since feature embedding through direct patch flattening or ResNet backbone in the standard ViT is not intended for CXR. To address this problem, here we propose a novel Vision Transformer that utilizes low-level CXR feature corpus obtained from a backbone network that extracts common CXR findings. Specifically, the backbone network is first trained with large public datasets to detect common abnormal findings such as consolidation, opacity, edema, etc. Then, the embedded features from the backbone network are used as corpora for a Transformer model for the diagnosis and the severity quantification of COVID-19. We evaluate our model on various external test datasets from totally different institutions to evaluate the generalization capability. The experimental results confirm that our model can achieve the state-of-the-art performance in both diagnosis and severity quantification tasks with superior generalization capability, which are sine qua non of widespread deployment.

Motivation & Objective

  • To address the challenge of limited labeled COVID-19 CXR data during the pandemic by leveraging abundant unlabeled CXR data with common abnormalities.
  • To improve generalization in COVID-19 diagnosis and severity quantification by decoupling feature learning from disease classification.
  • To develop a robust, transferable model that can be deployed widely across diverse clinical settings with minimal domain shift.
  • To demonstrate that low-level CXR features from pre-trained models serve as optimal corpora for ViT in medical imaging tasks.

Proposed method

  • Pre-train a backbone network on a large public CXR dataset (e.g., CheXpert) to detect common low-level findings such as consolidation, opacity, and edema.
  • Extract feature embeddings from the pre-trained backbone as a structured corpus for the Vision Transformer.
  • Use the ViT architecture to attend to these learned feature embeddings, modeling long-range dependencies across the CXR for high-level diagnosis.
  • Apply ROI max-pooling to convert per-patch severity maps into a global severity score array, improving alignment with clinical labeling.
  • Fine-tune the ViT on limited labeled COVID-19 data while keeping the backbone frozen to prevent overfitting.
  • Train the model using mean squared error (MSE) for severity quantification and binary cross-entropy for diagnosis, with data augmentation and institutional data diversity to enhance robustness.

Experimental results

Research questions

  • RQ1Can low-level CXR feature embeddings from a pre-trained model serve as an effective corpus for Vision Transformers in diagnosing COVID-19?
  • RQ2Does using a pre-trained feature corpus improve generalization performance on external, unseen datasets compared to standard ViT or CNN baselines?
  • RQ3How does the choice of ROI pooling (max vs. average) affect severity quantification performance?
  • RQ4Can the model achieve performance comparable to clinical experts in severity prediction using only CXR images?
  • RQ5Does including institutional data from diverse sources during training significantly improve generalization in severity quantification?

Key findings

  • The proposed model achieved a mean severity prediction MSE of 1.655 across three external datasets, outperforming the baseline ViT with direct patch embedding and hybrid ViT with ResNet features.
  • On external test sets from CNUH, YNU, and KNUH, the model achieved superior generalization performance, with MSE values of 1.682, 1.677, and 1.607 respectively.
  • The use of ROI max-pooling for severity map aggregation reduced MSE by 0.191 compared to average pooling, demonstrating its superiority in capturing localized abnormalities.
  • Excluding institutional datasets from training degraded performance significantly (MSE = 2.503 on CNUH), confirming the necessity of diverse data for stable severity prediction.
  • The model achieved state-of-the-art performance in both diagnosis and severity quantification, with performance comparable to clinical experts in severity scoring.
  • The model’s robustness across multiple institutions confirms its potential for real-world deployment in low-resource or under-resourced healthcare settings.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.