[Paper Review] VUV Reflectance Measurements for Materials Relevant to Argon and Xenon Experiments
This paper develops an angular-resolved reflectance measurement system in gaseous argon to measure VUV reflectance of detector materials, finding 10–15% VUV reflectance at 45° for aluminum and stainless steel, with UV-VIS values ~60% and ~40% respectively.
Accurate knowledge of material reflectance in the vacuum ultraviolet (VUV) range is crucial for optimizing photon detection in noble gas detectors such as DUNE. Despite its importance, reflectance values for detector materials in the VUV region remain poorly characterized, with literature values showing significant variation depending on surface termination and finish. We present an angular-resolved reflectance measurement system developed at IFIC that operates in a gaseous argon atmosphere, enabling realistic measurements of detector materials under controlled conditions. The setup couples a deuterium lamp to a monochromator and employs a motorized PMT rotating around the sample to measure reflected light distributions across a wide angular range. We have characterized two key DUNE materials -- aluminum field cage profiles and stainless steel cryostat membranes -- in both the UV-VIS (300-500 nm) and VUV (128-200 nm) ranges. In the UV-VIS region, we confirm literature values of approximately 60% reflectance for aluminum and 40% for stainless steel. Preliminary VUV measurements at 45° angle of incidence yield reflectance values of 10-15% for both materials, significantly lower than their UV-VIS counterparts. The reflected light distributions exhibit a mixed character between specular and diffuse reflection. These results have direct implications for detector simulations and light yield predictions in next-generation experiments.
Motivation & Objective
- Motivate accurate light-yield simulations for noble-gas detectors by characterizing material reflectance in the VUV range.
- Develop an angular-resolved reflectance measurement system operating in gaseous argon to mimic detector conditions.
- Measure reflectance of two DUNE-relevant materials (aluminum and stainless steel) across UV-VIS and VUV ranges.
- Provide data to improve photon transport models and detector simulations for next-generation experiments.
Proposed method
- Use a deuterium and tungsten lamp coupled to a monochromator to select wavelengths from 115–550 nm.
- Maintain a pure gaseous argon environment in a dark room for VUV measurements.
- Employ a motorized PMT to scan reflected light across a wide angular range at fixed incidence angles.
- Model the reflected intensity with a two-term shading-function: I(theta)=sum_i A_i cos^n_i(theta-x0).
- Apply a ring-model correction to estimate total hemispherical reflectance for metallic samples beyond the PMT acceptance.

Experimental results
Research questions
- RQ1What are the VUV reflectance values of aluminum and stainless steel at representative angles of incidence (e.g., 45°) in a gaseous argon environment?
- RQ2How do the angular distributions of VUV reflected light compare to UV-VIS in detector-relevant materials?
- RQ3Can an angular-resolved VUV reflectance measurement improve photon-transport simulations for noble-gas detectors?
- RQ4Do the measured VUV reflectances differ from commonly used values in DUNE simulations, and by how much?
- RQ5What is the extent of specular versus diffuse reflection in these materials at VUV wavelengths?
Key findings
- UV-VIS reflectance for aluminum is about 60% and for stainless steel about 40%, consistent with literature for real detector samples.
- In the VUV range (128–200 nm) at 45° incidence, preliminary reflectance values are 10–15% for both aluminum and stainless steel.
- Angular reflectance distributions in VUV show a mixed specular-diffuse character, not purely specular or Lambertian.
- The measurement system operates in gaseous argon, offering flexibility beyond vacuum-based setups for angular-resolved VUV measurements.
- Integrated (hemispherical) VUV reflectance at 45° AOI is substantially lower than UV-VIS values and lower than commonly used DUNE simulation assumptions (10–15% vs 60%/40%).
- Results imply re-evaluation of surface contributions to light yield and the need for realistic angular distributions in simulations.

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.