Skip to main content
QUICK REVIEW

[Paper Review] Weighted Temporal Decay Loss for Learning Wearable PPG Data with Sparse Clinical Labels

Yunsung Chung, Keum San Chun|arXiv (Cornell University)|Feb 2, 2026
Non-Invasive Vital Sign MonitoringEngineering0 citations
TL;DR

The paper introduces a weighted temporal decay loss that learns biomarker-specific decay of sample weight based on time gap between PPG segments and ground-truth labels, enabling learning from temporally distant labels and improving multi-biomarker prediction from smartwatch PPG.

ABSTRACT

Advances in wearable computing and AI have increased interest in leveraging PPG for health monitoring over the past decade. One of the biggest challenges in developing health algorithms based on such biosignals is the sparsity of clinical labels, which makes biosignals temporally distant from lab draws less reliable for supervision. To address this problem, we introduce a simple training strategy that learns a biomarker-specific decay of sample weight over the time gap between a segment and its ground truth label and uses this weight in the loss with a regularizer to prevent trivial solutions. On smartwatch PPG from 450 participants across 10 biomarkers, the approach improves over baselines. In the subject-wise setting, the proposed approach averages 0.715 AUPRC, compared to 0.674 for a fine-tuned self-supervised baseline and 0.626 for a feature-based Random Forest. A comparison of four decay families shows that a simple linear decay function is most robust on average. Beyond accuracy, the learned decay rates summarize how quickly each biomarker's PPG evidence becomes stale, providing an interpretable view of temporal sensitivity.

Motivation & Objective

  • Address the challenge of sparse clinical labels for PPG-based biomarker prediction.
  • Introduce a biomarker-specific learnable temporal decay rate to weight training samples by time gap.
  • Show performance gains over baselines on 10 biomarkers from smartwatch data.
  • Demonstrate data efficiency by leveraging temporally distant signals during training.
  • Provide interpretability by analyzing learned temporal sensitivity per biomarker.

Proposed method

  • Define a weighted loss where sample weight w_i = g(alpha_b_hat * Delta_t_i) with Delta_t_i as days to nearest health record and alpha_b_hat = softplus(alpha_b) >= 0.
  • Train with a weighted binary cross-entropy plus a mean-weight bonus to prevent degenerate weights (lambda fixed to 0.5).
  • Explore four decay families (exponential, linear, cosine annealing, inverse) and select linear as robust on average.
  • Use 10-second PPG segments from 450 participants, quality-filtered, aligned with nearest clinical record within 30 days, and evaluate with 5-fold cross-validation by subject.
  • Compare against a Random Forest on handcrafted features and PAPAGEI fine-tuned with the proposed loss.
Fig. 1 : The proposed method uses a weighted decay loss function, parameterized by $\Delta t$ – the temporal distance between the nearest sparse clinical label and the corresponding sensor data – to progressively reduce the contribution of the samples as they occur further from the clinical health r
Fig. 1 : The proposed method uses a weighted decay loss function, parameterized by $\Delta t$ – the temporal distance between the nearest sparse clinical label and the corresponding sensor data – to progressively reduce the contribution of the samples as they occur further from the clinical health r

Experimental results

Research questions

  • RQ1Can a time-aware weighting scheme improve biomarker prediction from PPG when clinical labels are sparse?
  • RQ2Which decay family provides the most robust performance across multiple biomarkers?
  • RQ3Does learning a biomarker-specific decay rate improve results beyond a fixed rate or no time weighting?
  • RQ4How does the method perform under a two-extreme (top vs bottom quartile) label setup?
  • RQ5What are the potential limitations and biomarker-specific dynamics affecting performance?

Key findings

  • Average AUROC 0.712 and AUPRC 0.715 across biomarkers, outperforming PAPAGEI (AUROC 0.660, AUPRC 0.674) and RF (AUROC 0.599, AUPRC 0.626).
  • Linear decay yielded the strongest average performance (AUROC 0.712, AUPRC 0.715).
  • Learning a biomarker-specific decay rate provided additional gains over a fixed rate ablation.
  • Time-aware weighting reduced reliance on distant segments and improved aggregation of segment predictions per subject.
  • Two-extreme protocol results show especially strong gains for fast-changing biomarkers like WBC and Potassium.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.