TL;DR

WeNLEX is a weakly supervised framework that generates faithful and plausible natural language explanations for multilabel chest X-ray predictions, using image-driven faithfulness and distribution-aligned plausibility, operable in post-hoc or in-model settings and adaptable to lay audiences.

ABSTRACT

Natural language explanations provide an inherently human-understandable way to explain black-box models, closely reflecting how radiologists convey their diagnoses in textual reports. Most works explicitly supervise the explanation generation process using datasets annotated with explanations. Thus, though plausible, the generated explanations are not faithful to the model's reasoning. In this work, we propose WeNLEX, a weakly supervised model for the generation of natural language explanations for multilabel chest X-ray classification. Faithfulness is ensured by matching images generated from their corresponding natural language explanations with original images, in the black-box model's feature space. Plausibility is maintained via distribution alignment with a small database of clinician-annotated explanations. We empirically demonstrate, through extensive validation on multiple metrics to assess faithfulness, simulatability, diversity, and plausibility, that WeNLEX is able to produce faithful and plausible explanations, using as little as 5 ground-truth explanations per diagnosis. Furthermore, WeNLEX can operate in both post-hoc and in-model settings. In the latter, i.e., when the multilabel classifier is trained together with the rest of the network, WeNLEX improves the classification AUC of the standalone classifier by 2.21%, thus showing that adding interpretability to the training process can actually increase the downstream task performance. Additionally, simply by changing the database, WeNLEX explanations are adaptable to any target audience, and we showcase this flexibility by training a layman version of WeNLEX, where explanations are simplified for non-medical users.

Motivation & Objective

  • Motivate explainability in medical imaging by producing human-understandable NLEs that faithfully reflect model reasoning.
  • Develop a weakly supervised framework to generate NLEs with limited ground-truth explanations.
  • Ensure plausibility via a small clinician-annotated NLE database and maintain faithfulness through image-feature reconstruction in the model’s space.
  • Demonstrate applicability in both post-hoc and in-model training settings and show potential task performance gains.

Proposed method

  • Adopt a predict-explain paradigm generating one NLE per predicted label for multilabel chest X-ray classifications.
  • Use a frozen text-only Encoder–Decoder NLE generator adapted with parameter-efficient tuning to take image features, the full prediction vector, and the target diagnosis text as input.
  • Impose plausibility via distribution alignment to a small database of ground-truth NLE embeddings using either WGAN-GP or Maximum Mean Discrepancy (MMD).
  • Enforce faithfulness with a feature-space reconstruction loss where generated NLEs are mapped to an image via a Text Embedding to Image module and compared against the MBE’s features; additionally, enforce that the NLE preserves the MBE’s diagnosis prediction.
  • In-model training optionally updates the classifier jointly with NLE generation and uses a frozen classifier copy to stabilize training; otherwise, in the post-hoc setting the classifier is frozen while NLEs are learned.
  • Combine losses (plausibility, NLE classification alignment, image-feature reconstruction) with automatic loss weighting to form the overall objective; in the in-model case add an image-classification loss term for joint optimization.
Figure 1 : Architecture of WeNLEX , a weakly supervised model that generates natural language explanations (NLEs) for a multilabel X-ray classifier. For each predicted diagnosis (e.g., atelectasis, edema), it produces an NLE (only the atelectasis NLE is shown). A pretrained, frozen text-only Encoder
Figure 1 : Architecture of WeNLEX , a weakly supervised model that generates natural language explanations (NLEs) for a multilabel X-ray classifier. For each predicted diagnosis (e.g., atelectasis, edema), it produces an NLE (only the atelectasis NLE is shown). A pretrained, frozen text-only Encoder

Experimental results

Research questions

  • RQ1Can a weakly supervised framework generate natural language explanations for multilabel chest X-ray predictions that are faithful to the model’s reasoning?
  • RQ2Does aligning generated NLEs to a small clinician-annotated NLE database (plausibility) and enforcing image-feature reconstruction (faithfulness) improve quality across various metrics?
  • RQ3Are WeNLEX explanations adaptable to different audiences (e.g., laypeople) by changing the NLE database?
  • RQ4Do post-hoc and in-model training setups differ in explanatory quality and downstream classification performance?
  • RQ5Can incorporating NLE generation during training improve downstream AUC for the classifier?

Key findings

  • WeNLEX can generate faithful and plausible NLEs using as few as five ground-truth NLEs per diagnosis.
  • MMD-based plausibility loss outperforms adversarial loss in aligning generated NLE distributions with ground-truth NLE embeddings and yields higher simulatability and plausibility metrics.
  • Feature reconstruction loss improves faithfulness and diversity of NLEs, with some trade-offs in ground-truth NLE similarity.
  • NLE-based training (in-model) achieves better performance and higher fidelity metrics than post-hoc, including improved downstream AUC in some configurations.
  • A layman version of WeNLEX can produce simplified explanations targeting non-medical users without sacrificing core faithfulness gains.
  • The framework supports both post-hoc and in-model operation, and demonstrates robustness across multiple evaluation dimensions (faithfulness, simulatability, diversity, plausibility).
Figure 2 : Depiction of the deletion faithfulness metric: an image and a generated NLE are given to CheXagent, which grounds the text in the image. The identified regions are occluded, and the masked image is given to the model being explained (MBE). If the NLE is faithful, occluding these regions s
Figure 2 : Depiction of the deletion faithfulness metric: an image and a generated NLE are given to CheXagent, which grounds the text in the image. The identified regions are occluded, and the masked image is given to the model being explained (MBE). If the NLE is faithful, occluding these regions s

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.