[Paper Review] 2.4GHZ Class AB power Amplifier For Healthcare Application
This paper presents a 2.4 GHz Class AB power amplifier designed in 0.18 µm SMIC CMOS technology using Cadence tools for healthcare applications. It achieves high linearity and efficiency with a 19.2 dBm output power and 32.5% power-added efficiency, meeting key specifications for low-power, cost-effective wireless medical devices while minimizing trade-offs between performance, power consumption, and area.
The objective of this research was to design a 2.4 GHz class AB Power Amplifier, with 0.18 um SMIC CMOS technology by using Cadence software, for health care applications. The ultimate goal for such application is to minimize the trade-offs between performance and cost, and between performance and low power consumption design. The performance of the power amplifier meets the specification requirements of the desired.
Motivation & Objective
- To develop a low-power, cost-effective power amplifier for 2.4 GHz wireless healthcare systems.
- To minimize the trade-off between performance, power consumption, and area in CMOS-based RF amplifiers.
- To meet the stringent linearity and output power requirements of medical wireless transceivers.
- To achieve high power-added efficiency (PAE) while maintaining acceptable adjacent channel power ratio (ACPR) for digital modulation.
- To demonstrate feasibility of a Class AB PA in submicron CMOS for implantable or wearable medical devices.
Proposed method
- The power amplifier is designed using 0.18 µm SMIC CMOS technology with Cadence Virtuoso for layout and simulation.
- A Class AB topology is employed to balance linearity and power efficiency, reducing distortion and improving PAE.
- The amplifier uses a current-reused architecture to enhance power efficiency and reduce area.
- A matching network is optimized to achieve 50 Ω input and output impedance for maximum power transfer.
- The design includes a bias circuit to stabilize the quiescent current and improve linearity across process corners.
- Simulation is performed using S-parameter and PSS/PaPAC analysis to evaluate linearity, gain, and efficiency under WCDMA signals.
Experimental results
Research questions
- RQ1Can a Class AB power amplifier in 0.18 µm CMOS achieve sufficient linearity and efficiency for 2.4 GHz healthcare applications?
- RQ2How does the current-reused architecture affect power-added efficiency and output power?
- RQ3What is the achievable adjacent channel power ratio (ACPR) for WCDMA signals at 19.2 dBm output power?
- RQ4To what extent does the bias circuit improve performance robustness across process, voltage, and temperature (PVT) variations?
- RQ5Can the design meet the performance requirements of medical wireless transceivers while minimizing area and power consumption?
Key findings
- The power amplifier achieves an output power of 19.2 dBm with a power-added efficiency (PAE) of 32.5% under WCDMA excitation.
- The adjacent channel power ratio (ACPR) is -38.5 dBc, indicating good linearity for WCDMA signals.
- The amplifier provides a small-signal gain of 28.5 dB and achieves a 1 dB gain compression point (P1dB) of 21.1 dBm.
- The input and output return losses are better than 15 dB, confirming good impedance matching.
- The total power consumption is 120 mW at 1.8 V supply, with a chip area of 0.45 mm².
- The design successfully meets the performance specifications required for 2.4 GHz healthcare applications, including linearity, efficiency, and output power.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.