This paper proposes a 4D deep learning framework using a multi-encoder-decoder architecture with convolutional gated recurrent units (convGRUs) to improve multiple sclerosis lesion activity segmentation by incorporating temporal history beyond just baseline and follow-up scans. The method outperforms prior approaches, achieving a lesion-wise true positive rate of 0.84 at a false positive rate of 0.19, demonstrating that extended temporal context enhances detection accuracy.
Multiple sclerosis lesion activity segmentation is the task of detecting new and enlarging lesions that appeared between a baseline and a follow-up brain MRI scan. While deep learning methods for single-scan lesion segmentation are common, deep learning approaches for lesion activity have only been proposed recently. Here, a two-path architecture processes two 3D MRI volumes from two time points. In this work, we investigate whether extending this problem to full 4D deep learning using a history of MRI volumes and thus an extended baseline can improve performance. For this purpose, we design a recurrent multi-encoder-decoder architecture for processing 4D data. We find that adding more temporal information is beneficial and our proposed architecture outperforms previous approaches with a lesion-wise true positive rate of 0.84 at a lesion-wise false positive rate of 0.19.
Motivation & Objective
- To improve lesion activity segmentation in multiple sclerosis by leveraging temporal MRI history beyond two time points.
- To investigate whether extending the baseline with a historical scan enhances detection performance.
- To design a deep learning architecture that efficiently processes 4D spatio-temporal MRI data with shared parameters across time points.
- To compare recurrent temporal aggregation via convGRUs against standard feature concatenation in the decoder.
Proposed method
- The model uses a ResNet-based 3D CNN with a multi-encoder-decoder structure, processing T time points in parallel with shared weights across temporal paths.
- Temporal aggregation is performed using convolutional gated recurrent units (convGRUs) between the encoder and decoder to model spatio-temporal dependencies.
- Long-range skip connections in the network also employ the same convGRU-based recurrence for temporal feature fusion.
- The architecture supports arbitrary numbers of time points without increasing model parameters, enabling scalability to longer temporal sequences.
- Instance normalization is applied due to the small batch size of one during training.
- During inference, overlapping crops are used to reconstruct full lesion activity maps, with overlapping regions averaged.
Experimental results
Research questions
- RQ1Does incorporating a historical MRI scan (beyond baseline and follow-up) improve lesion activity segmentation performance?
- RQ2Is recurrent temporal aggregation via convGRUs more effective than simple feature concatenation for 4D lesion activity prediction?
- RQ3Can a shared-weights, multi-path encoder-decoder architecture generalize across variable numbers of time points?
- RQ4How does the inclusion of temporal context affect the trade-off between true positive and false positive rates in lesion detection?
- RQ5Is the proposed architecture scalable to longer temporal sequences with minimal parameter growth?
Key findings
- The proposed Enc-convGRU-Dec model with T=3 time points achieved a lesion-wise true positive rate of 0.84, outperforming all prior methods.
- At a lesion-wise false positive rate of 0.19, the model achieved a Dice score of 0.64, representing a significant improvement over the previous state-of-the-art.
- The use of convGRUs for temporal aggregation yielded better performance than feature concatenation, even with only T=2 scans.
- Adding a historical scan (T=3) improved performance over T=2 when using the convGRU-based architecture, indicating benefit from extended temporal context.
- The model maintains consistent performance across different numbers of time points due to parameter-sharing, enabling scalability to longer sequences.
- The architecture demonstrated robustness and generalization, with overlapping inference crops producing reliable full-volume lesion activity maps.