This paper presents a 0.042 mm² programmable biphasic stimulator for cochlear implants that uses double-loop negative feedback and a two-stage binary-weighted transistor DAC to achieve high output impedance and low power consumption. The design enables charge-balanced stimulation without a dc blocking capacitor, significantly reducing area and enabling integration of a large number of stimulation channels.
This paper presents a compact programmable biphasic stimulator for cochlear implants. By employing double-loop negative feedback, the output impedance of the current generator is increased, while maximizing the voltage compliance of the output transistor. To make the stimulator circuit compact, the stimulation current is set by scaling a reference current using a two stage binary-weighted transistor DAC (comprising a 3 bit high-voltage transistor DAC and a 4 bit low-voltage transistor DAC). With this structure the power consumption and the area of the circuit can be minimized. The proposed circuit has been implemented in AMS 0.18um high-voltage CMOS IC technology, using an active chip area of about 0.042mm^2. Measurement results show that proper charge balance of the anodic and cathodic stimulation phases is achieved and a dc blocking capacitor can be omitted. The resulting reduction in the required area makes the proposed system suitable for a large number of channels.
Motivation & Objective
- To develop a compact, low-power stimulator for cochlear implants capable of supporting a large number of stimulation channels.
- To address the challenge of minimizing chip area while maintaining precise current control and charge balance.
- To eliminate the need for a bulky DC blocking capacitor by ensuring inherent charge balance in the stimulation waveform.
- To reduce power consumption and area through innovative current generation and DAC architecture.
Proposed method
- Employed double-loop negative feedback to increase output impedance and maximize voltage compliance of the output transistor.
- Implemented a two-stage binary-weighted transistor DAC using a 3-bit high-voltage and a 4-bit low-voltage stage to scale a reference current.
- Designed the current generator to achieve precise, programmable stimulation currents with minimal area and power.
- Used AMS 0.18 µm high-voltage CMOS technology to fabricate the circuit with an active area of only 0.042 mm².
- Optimized the circuit for charge-balanced biphasic stimulation to prevent tissue damage and eliminate the need for external DC blocking capacitors.
- Integrated the stimulator within a compact footprint suitable for high-channel-count cochlear implant systems.
Experimental results
Research questions
- RQ1Can a compact stimulator with minimal area and power consumption achieve precise, charge-balanced biphasic stimulation for cochlear implants?
- RQ2How can output impedance be maximized and voltage compliance improved in a sub-0.05 mm² area?
- RQ3Is it possible to eliminate the DC blocking capacitor while maintaining charge balance in a programmable stimulator?
- RQ4What DAC architecture enables high-resolution current control with minimal area and power in a high-voltage CMOS process?
- RQ5Can a single-channel stimulator be scaled efficiently to support a large number of channels in a cochlear implant system?
Key findings
- The stimulator achieves charge-balanced biphasic stimulation without requiring a DC blocking capacitor, reducing system complexity and area.
- The active chip area is only 0.042 mm², making it highly suitable for integration into high-channel-count cochlear implant systems.
- The double-loop feedback structure successfully increases output impedance and improves voltage compliance of the output transistor.
- The two-stage binary-weighted DAC enables precise current control with minimal area and low power consumption.
- Measurement results confirm that the stimulator maintains proper charge balance across both anodic and cathodic phases.
- The design reduces power consumption and chip area, enabling scalable implementation for future multichannel cochlear implants.