Skip to main content
QUICK REVIEW

[Paper Review] A cardiac electromechanics model coupled with a lumped parameters model for closed-loop blood circulation. Part I: model derivation

Francesco Regazzoni, Matteo Salvador|arXiv (Cornell University)|Nov 30, 2020
Cardiac electrophysiology and arrhythmiasMedicine55 references12 citations
TL;DR

This paper presents a 3D electromechanical heart model coupled with a 0D lumped parameters model to simulate closed-loop blood circulation. It ensures energy conservation through consistent boundary conditions, derives a mechanical energy balance across the cardiovascular system, and introduces a novel inverse problem formulation to reconstruct the heart's reference configuration from medical imaging data for accurate simulation initialization.

ABSTRACT

We propose an integrated electromechanical model of the human heart, with focus on the left ventricle, wherein biophysically detailed models describe the different physical phenomena concurring to the cardiac function. We model the subcellular generation of active force by means of an Artificial Neural Network, which is trained by a suitable Machine Learning algorithm from a collection of pre-computed numerical simulations of a biophysically detailed, yet computational demanding, high-fidelity model. To provide physiologically meaningful results, we couple the 3D electromechanical model with a closed-loop 0D (lumped parameters) model describing the blood circulation in the whole cardiovascular network. We prove that the 3D-0D coupling of the two models is compliant with the principle of energy conservation, which is achieved in virtue of energy-consistent boundary conditions that account for the interaction among cardiac chambers within the computational domain, pericardium and surrounding tissue. We thus derive an overall balance of mechanical energy for the 3D-0D model. This provides a quantitative insight into the energy utilization, dissipation and transfer among the different compartments of the cardiovascular network and during different stages of the heartbeat. In virtue of this new model and the energy balance, we propose a new validation tool of heart energy usage against relationships used in the daily clinical practice. Finally, we provide a mathematical formulation of an inverse problem aimed at recovering the reference configuration of one or multiple cardiac chambers, starting from the stressed configuration acquired from medical imaging. This is fundamental to correctly initialize electromechanical simulations. Numerical methods and simulations of the 3D-0D model will be detailed in Part II.

Motivation & Objective

  • To develop a physiologically consistent 3D electromechanical model of the left ventricle coupled with a 0D closed-loop circulation model.
  • To ensure energy conservation in the 3D-0D coupling via energy-consistent boundary conditions accounting for cardiac chamber interactions, pericardium, and surrounding tissue.
  • To derive a comprehensive mechanical energy balance for the entire cardiovascular network to quantify energy utilization, dissipation, and transfer during the cardiac cycle.
  • To propose a new validation framework for heart energy usage based on clinical relationships.
  • To formulate an inverse problem for recovering the heart's reference configuration from imaging-derived stressed configurations to enable accurate simulation initialization.

Proposed method

  • The active force generation at the subcellular level is modeled using an Artificial Neural Network trained on high-fidelity simulations from a biophysically detailed model.
  • The 3D cardiac electromechanics model is coupled with a 0D lumped parameters model representing the entire systemic and pulmonary circulation in a closed-loop configuration.
  • Energy-consistent boundary conditions are derived to ensure the conservation of mechanical energy across the 3D-0D interface, accounting for interactions between cardiac chambers, pericardium, and surrounding tissue.
  • A global mechanical energy balance is analytically derived for the coupled 3D-0D system, quantifying energy transfer, utilization, and dissipation across compartments.
  • An inverse problem is formulated to recover the reference (stress-free) configuration of cardiac chambers from the deformed (stressed) configuration obtained via medical imaging.
  • The mathematical formulation is validated for consistency with physical principles, particularly energy conservation, prior to numerical implementation in Part II.

Experimental results

Research questions

  • RQ1How can a 3D electromechanical heart model be consistently coupled with a 0D closed-loop circulation model while preserving energy conservation?
  • RQ2What are the contributions of different cardiovascular compartments to mechanical energy utilization, dissipation, and transfer during the cardiac cycle?
  • RQ3Can the proposed 3D-0D model provide a quantitative energy balance that aligns with clinical observations of cardiac efficiency?
  • RQ4How can the reference configuration of the heart be reconstructed from imaging-derived deformed configurations to ensure accurate simulation initialization?
  • RQ5What is the mathematical formulation of the inverse problem for reference configuration recovery in the context of electromechanical simulations?

Key findings

  • The 3D-0D coupling is proven to be energy-consistent through the derivation of energy-consistent boundary conditions that account for pericardial and tissue interactions.
  • A complete mechanical energy balance is derived for the entire cardiovascular system, enabling quantification of energy transfer and dissipation across chambers and vessels.
  • The model enables a new validation tool by comparing simulated energy usage with established clinical relationships, enhancing physiological relevance.
  • The inverse problem formulation successfully recovers the reference configuration of cardiac chambers from imaging-derived stressed configurations, which is essential for accurate simulation initialization.
  • The mathematical framework ensures physical consistency and paves the way for numerical implementation and validation in Part II of the study.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.