This study investigates the impacts of the August 21, 2017 partial solar eclipse on two distributed photovoltaic (PV) systems in Florida—1.4 MW in Miami and 355 kW in Daytona—using four analyses: PV performance via power performance index, power quality at the point of interconnection, voltage regulation device operation in a simulated IEEE 8500 feeder, and reliability forecasting using a multilayer perceptron. Key findings show that the eclipse caused significant, rapid ramp-downs in irradiance and temperature, leading to pronounced performance drops and increased voltage regulation activity, especially at high PV penetration levels.
Photovoltaic (PV) systems depend on irradiance, ambient temperature and module temperature. A solar eclipse causes significant changes in these parameters, thereby impacting PV generation profile, performance, and power quality of larger grid where they connect to. This paper presents a case study to evaluate the impacts of the solar eclipse of August 21, 2017 on two real-world grid-tied PV systems (1.4MW and 355kW) in Miami and Daytona, Florida, the feeders they are connected to, and the management areas they belong to. Four types of analyses are conducted to obtain a comprehensive picture of the impacts using 1-minute PV generation data, hourly weather data, real feeder parameters, and daily reliability data. These analyses include: individual PV system performance measurement using power performance index; power quality analysis at the point of interconnection; a study on the operation of voltage regulating devices on the feeders during eclipse peak using an IEEE 8500 test case distribution feeder; and reliability study involving a multilayer perceptron framework for forecasting system reliability of the management areas. Results from this study provide a unique insight into how solar eclipses impact the behavior of PV systems and the grid, which would be of concern to electric utilities in future high penetration scenarios.
Motivation & Objective
- To evaluate the effects of the 2017 partial solar eclipse on distributed PV systems in real-world grid-tied settings in Florida.
- To analyze power quality impacts at the point of interconnection (POI) of a 1.4 MW PV system during the eclipse.
- To simulate the operational response of voltage regulation devices (e.g., regulators, capacitors) on distribution feeders during the eclipse-induced ramp-down.
- To forecast and assess the reliability of utility management areas (Miami and Daytona) using weather data and a multilayer perceptron (MLP) framework.
- To provide actionable insights for utilities on preparing for future eclipses under high PV penetration scenarios.
Proposed method
- Measured 1-minute resolution PV generation data from cloud-based on-site data acquisition systems for performance analysis.
- Collected 1-minute resolution power quality data (RMS voltage, harmonics, flicker) at the POI of the Miami system using a power quality meter.
- Simulated the IEEE 8500-node test feeder with real feeder parameters and PV system data to analyze voltage profile changes and regulator operations.
- Applied a multilayer perceptron (MLP) framework to forecast daily reliability indices using hourly weather data (e.g., temperature, lightning strikes).
- Conducted regression and sensitivity analysis to identify key weather parameters influencing distribution network reliability.
- Used power performance index (PPI) to quantify system performance changes during eclipse, correlating with irradiance, ambient, and module temperature.
Experimental results
Research questions
- RQ1How did the 2017 partial solar eclipse affect the performance of distributed PV systems in Miami and Daytona, Florida?
- RQ2What were the impacts on power quality metrics (voltage, harmonics, flicker) at the point of interconnection during the eclipse?
- RQ3How did the eclipse influence the operation of voltage regulation devices (e.g., regulators, capacitors) on the distribution feeder?
- RQ4To what extent do common weather parameters (e.g., temperature, lightning) affect distribution system reliability, and can these be used to forecast reliability during eclipse events?
- RQ5How do the dynamics of PV ramp-down and environmental parameter changes affect grid stability and operational planning under high PV penetration?
Key findings
- System A (1.4 MW in Miami) exhibited a slower performance decline during eclipse peak due to a more gradual drop in irradiance, ambient temperature, and module temperature compared to System B.
- System B (355 kW in Daytona) showed a steeper drop in irradiance and temperature, resulting in a more pronounced increase in power performance index (PPI), indicating a stronger performance impact.
- Strong positive correlations were observed between irradiance, ambient temperature, and module temperature both within and across systems, suggesting potential for aggregation-based forecasting.
- Power quality metrics (RMS voltage, harmonics, flicker) remained within IEEE standards during the eclipse, but the potential for severe disturbances increases with higher PV penetration.
- Voltage regulation devices, including regulators and capacitor banks, operated more frequently during the eclipse-induced ramp-down, especially near PV-connected buses, with System B’s location causing a voltage rise at the POI.
- The eclipse increased system losses due to rapid PV output changes, and the MLP-based reliability forecasting model identified lightning strikes as the most influential weather parameter on reliability, while average temperature had the least impact.