Skip to main content
QUICK REVIEW

[Paper Review] Dealing in practice with hot-spots

R. B. Moreton, E. Lorenzo|arXiv (Cornell University)|Oct 30, 2014
Photovoltaic System Optimization TechniquesEnergy13 citations
TL;DR

This paper proposes a standardized, practical procedure for identifying and evaluating photovoltaic module hot-spots using visual inspection, infrared thermography, electroluminescence, and electrical performance tests. The operating voltage was identified as the most effective parameter for quantifying efficiency losses, offering a reliable metric for contractual assessments of module degradation and reliability.

ABSTRACT

The hot-spot phenomenon is a relatively frequent problem occurring in current photovoltaic generators. It entails both a risk for the photovoltaic module's lifetime and a decrease in its operational efficiency. Nevertheless, there is still a lack of widely accepted procedures for dealing with them in practice. This paper presents the IES-UPM observations on 200 affected modules. Visual and infrared inspection, electroluminescence, peak power and operating voltage tests have been accomplished. Hot-spot observation procedures and well defined acceptance and rejection criteria are proposed, addressing both the lifetime and the operational efficiency of the modules. The operating voltage has come out as the best parameter to control effective efficiency losses for the affected modules. This procedure is oriented to its possible application in contractual frameworks.

Motivation & Objective

  • To address the lack of widely accepted field procedures for detecting and evaluating photovoltaic module hot-spots.
  • To establish clear acceptance and rejection criteria for hot-spot-affected modules based on empirical data.
  • To identify the most effective electrical parameter for quantifying efficiency losses due to hot-spots.
  • To support contractual decision-making in PV system operations and maintenance.

Proposed method

  • Conducted visual and infrared inspections on 200 field-affected photovoltaic modules.
  • Performed electroluminescence imaging to detect microcracks and localized defects.
  • Measured peak power and operating voltage under standard test conditions to assess performance degradation.
  • Correlated thermal anomalies with electrical performance to identify efficiency losses.
  • Defined acceptance and rejection thresholds based on voltage deviation and thermal signatures.
  • Proposed a practical, repeatable framework for field application in maintenance and contractual settings.

Experimental results

Research questions

  • RQ1What are the most reliable field-identifiable indicators of hot-spot damage in photovoltaic modules?
  • RQ2Which electrical parameter most accurately reflects efficiency losses caused by hot-spots?
  • RQ3How can consistent acceptance and rejection criteria be established for hot-spot-affected modules in real-world applications?
  • RQ4To what extent do visual and infrared inspections correlate with actual performance degradation?
  • RQ5Can operating voltage serve as a practical metric for contractual evaluation of module health?

Key findings

  • The operating voltage was found to be the most sensitive and reliable indicator for detecting and quantifying efficiency losses in hot-spot-affected modules.
  • Visual and infrared inspections effectively identified thermal anomalies, but required confirmation with electrical testing for accuracy.
  • Electroluminescence imaging successfully revealed microcracks and localized defects associated with hot-spot formation.
  • A clear correlation was observed between thermal hot-spots and measurable reductions in peak power output.
  • The proposed criteria enabled consistent classification of modules as acceptable or rejectable in field conditions.
  • The procedure is suitable for integration into contractual frameworks for PV system performance guarantees.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.