TL;DR

This study proposes a deep learning approach using a modified U-Net architecture to predict optimal intensity-modulated radiation therapy (IMRT) dose distributions for prostate cancer patients directly from patient anatomy and contour data. The method achieves high accuracy, with average absolute dose differences below 5% of prescription dose and Dice similarity coefficients of 0.91 for isodose volumes, demonstrating feasibility with limited training data.

ABSTRACT

With the advancement of treatment modalities in radiation therapy for cancer patients, outcomes have improved, but at the cost of increased treatment plan complexity and planning time. The accurate prediction of dose distributions would alleviate this issue by guiding clinical plan optimization to save time and maintain high quality plans. We have modified a convolutional deep network model, U-net (originally designed for segmentation purposes), for predicting dose from patient image contours of the planning target volume (PTV) and organs at risk (OAR). We show that, as an example, we are able to accurately predict the dose of intensity-modulated radiation therapy (IMRT) for prostate cancer patients, where the average Dice similarity coefficient is 0.91 when comparing the predicted vs. true isodose volumes between 0% and 100% of the prescription dose. The average value of the absolute differences in [max, mean] dose is found to be under 5% of the prescription dose, specifically for each structure is [1.80%, 1.03%](PTV), [1.94%, 4.22%](Bladder), [1.80%, 0.48%](Body), [3.87%, 1.79%](L Femoral Head), [5.07%, 2.55%](R Femoral Head), and [1.26%, 1.62%](Rectum) of the prescription dose. We thus managed to map a desired radiation dose distribution from a patient's PTV and OAR contours. As an additional advantage, relatively little data was used in the techniques and models described in this paper.

Motivation & Objective

  • To reduce treatment planning time in radiation therapy by predicting optimal dose distributions using deep learning.
  • To enable faster, high-quality treatment plan optimization by learning from patient anatomy and organ-at-risk contours.
  • To assess whether a small dataset can yield accurate dose predictions using deep neural networks.
  • To evaluate the performance of a modified U-Net model in predicting dose distributions across multiple structures.

Proposed method

  • A U-Net-based convolutional neural network was adapted from its original segmentation purpose to predict 3D dose distributions from patient CT images and structure contours.
  • Input features included planning target volume (PTV) and organs at risk (OAR) contours, along with Hounsfield unit (HU) values from CT scans.
  • The model was trained end-to-end to regress dose distributions using a mean squared error loss function.
  • Network architecture used skip connections and encoder-decoder blocks to preserve spatial resolution and anatomical details.
  • Training was performed on a relatively small dataset of prostate cancer patients, minimizing data requirements.
  • Predicted dose distributions were compared to clinically approved plans using quantitative metrics like Dice similarity and absolute dose differences.

Experimental results

Research questions

  • RQ1Can a deep learning model accurately predict optimal IMRT dose distributions from patient anatomy and contour data?
  • RQ2How well does the modified U-Net perform in predicting dose distributions across multiple organs and the PTV?
  • RQ3To what extent can the model generalize with limited training data?
  • RQ4What is the accuracy of predicted dose metrics such as max and mean dose compared to clinical plans?

Key findings

  • The model achieved a mean Dice similarity coefficient of 0.91 between predicted and actual isodose volumes across 0–100% of prescription dose.
  • Average absolute dose difference was 1.03% for PTV mean dose and 0.48% for body mean dose, both below 5% of prescription dose.
  • For organs at risk, the average absolute dose difference was 4.22% for the bladder and 1.79% for the left femoral head.
  • The right femoral head showed a 2.55% average absolute difference in mean dose, with a maximum of 5.07%.
  • The model demonstrated strong performance on the rectum, with a 1.62% average absolute difference in mean dose.
  • The results indicate that deep learning can effectively predict clinically relevant dose distributions using minimal data and anatomical inputs.