Maryam Mashayekhi, Itzel Ramirez Tapia|arXiv (Cornell University)|Jun 15, 2021
Advanced Radiotherapy TechniquesPhysics and Astronomy48 references22 citations
TL;DR

This paper proposes a site-agnostic 3D dose prediction model using a 3D U-Net deep learning architecture that leverages transfer learning to generalize across treatment sites. By fine-tuning a model pre-trained on prostate IMRT data to head-and-neck VMAT data with minimal target data, the method achieves high accuracy—averaging 1.08% mean absolute dose error in PTV and 2.43% mean OAR dose error—demonstrating strong performance even with limited site-specific data.

ABSTRACT

Typically, the current dose prediction models are limited to small amounts of data and require re-training for a specific site, often leading to suboptimal performance. We propose a site-agnostic, 3D dose distribution prediction model using deep learning that can leverage data from any treatment site, thus increasing the total data available to train the model. Applying our proposed model to a new target treatment site requires only a brief fine-tuning of the model to the new data and involves no modifications to the model input channels or its parameters. Thus, it can be efficiently adapted to a different treatment site, even with a small training dataset.

Motivation & Objective

  • Address the limitation of current site-specific dose prediction models that require retraining and perform poorly with limited data.
  • Develop a universal, site-agnostic deep learning framework for 3D dose distribution prediction that can be adapted to new treatment sites with minimal retraining.
  • Improve model generalization and performance on new sites by leveraging data from diverse treatment sites through transfer learning.
  • Incorporate clinical DVH constraints into the model input to enable tunable, interactive dose prediction aligned with physician preferences.
  • Demonstrate that fine-tuning a pre-trained model on a new site outperforms training from scratch, especially with small datasets.

Proposed method

  • Utilized a 3D U-Net architecture as the backbone neural network for 3D dose prediction, trained on prostate IMRT data (source) and head-and-neck VMAT data (target).
  • Applied transfer learning by fine-tuning the source model (pre-trained on prostate data) on the target dataset, enabling adaptation without architectural changes.
  • Compared four models: source (trained on source data), target (trained from scratch on target data), adapted (fine-tuned source model on target data), and combined (trained on pooled source and target data).
  • Incorporated patient-specific DVH constraints as input features to guide predictions and enable tunable trade-offs between target coverage and OAR sparing.
  • Used dose-volume-histogram (DVH) metrics—including D98, D95, D02, mean, and max dose—as quantitative evaluation criteria for PTV and OARs.
  • Employed mean squared error (MSE) loss to evaluate model performance across varying training data sizes, assessing generalization under data scarcity.

Experimental results

Research questions

  • RQ1Can a deep learning model trained on one treatment site (prostate IMRT) generalize effectively to a different site (head-and-neck VMAT) without architectural changes?
  • RQ2How does fine-tuning a pre-trained model on a new site compare to training from scratch in terms of prediction accuracy with limited target data?
  • RQ3Does combining data from multiple treatment sites improve model performance on a new target site, despite data imbalance?
  • RQ4To what extent does incorporating DVH constraints into the input enhance the model’s clinical relevance and tunability?
  • RQ5How sensitive is model performance to the size of the training dataset, especially in low-data regimes?

Key findings

  • The source model achieved a mean absolute dose error of 0.32%±0.14 and a maximum error of 2.37%±0.93 for the PTV when tested on prostate IMRT data.
  • On the head-and-neck VMAT target site, the adapted model achieved a mean absolute dose error of 1.08%±0.95 and a maximum error of 2.90%±1.35 for the PTV.
  • The adapted model outperformed the target model (trained from scratch) on the target site, especially with small training data, achieving lower MSE loss even at 10% of the full dataset.
  • The combined model, trained on pooled source and target data, showed improved performance on the source site but underperformed on the target site due to data imbalance and modality differences.
  • The adapted model achieved an average OAR mean dose error of 2.43% and OAR max dose error of 4.33% across all OARs on the target site, demonstrating strong generalization.
  • The model’s performance was highly dependent on training data size, with the adapted model showing the most stable and lowest loss across all data scales, indicating robustness to data scarcity.