[Paper Review] A megapixel time-gated SPAD image sensor for 2D and 3D imaging applications
This paper presents the first 1-megapixel time-gated SPAD image sensor fabricated in 180nm CIS technology, achieving 3.8ns time gating and 24kfps frame rate. It enables high-precision 2D and 3D imaging over 2m with sub-8mm precision, demonstrates extended dynamic range via dual exposure, and enables spatially overlapped multi-object detection in single-photon time-gated ToF for the first time.
We present the first 1Mpixel SPAD camera ever reported. The camera features 3.8ns time gating and 24kfps frame rate; it was fabricated in 180nm CIS technology. Two pixels have been designed with a pitch of 9.4$μ$m in 7T and 5.75T configurations, respectively, achieving a maximum fill factor of 13.4%. The maximum PDP is 27%, median DCR 2.0cps, variation in gating length 120ps, position skew 410ps, and rise/fall time <550ps, all FWHM at 3.3V of excess bias. The sensor was used to capture 2D/3D scenes over 2m with an LSB of 5.4mm and a precision better than 7.8mm. Extended dynamic range is demonstrated in dual exposure operation mode. Spatially overlapped multi-object detection is experimentally demonstrated in single-photon time-gated ToF for the first time.
Motivation & Objective
- To develop a high-resolution, high-speed SPAD image sensor for advanced 2D and 3D imaging applications.
- To overcome limitations in fill factor, dark count rate, and timing jitter in existing SPAD sensors at megapixel scale.
- To enable time-gated single-photon detection with sub-4ns resolution for precise depth sensing.
- To demonstrate extended dynamic range and multi-object detection in single-photon time-gated ToF imaging.
Proposed method
- Design of two SPAD pixel architectures with 9.4µm and 5.75µm pitches in 7T and 5.75T configurations, respectively, to optimize fill factor and performance.
- Implementation of 3.8ns time-gating capability using a 3.3V excess bias, achieving <550ps rise/fall times and 120ps jitter in gating length.
- Integration of time-gated operation with a 24kfps frame rate to support high-speed 3D imaging.
- Use of dual exposure mode to extend dynamic range by combining short and long exposure measurements.
- Employment of time-gated single-photon counting for depth resolution with 5.4mm LSB and <7.8mm precision over 2m.
- Demonstration of spatially overlapped multi-object detection by resolving time-of-flight signals from multiple objects within the same time gate.
Experimental results
Research questions
- RQ1Can a megapixel SPAD sensor achieve sub-4ns time-gating resolution while maintaining high fill factor and low dark count rate?
- RQ2What is the achievable depth resolution and precision in time-gated single-photon 3D imaging using a megapixel SPAD array?
- RQ3Can dual exposure operation in a time-gated SPAD sensor effectively extend dynamic range in low-light conditions?
- RQ4Is it feasible to detect multiple spatially overlapped objects in a single time-gated ToF measurement using a megapixel SPAD sensor?
- RQ5How do timing jitter and position skew affect depth accuracy in a high-speed, high-resolution SPAD image sensor?
Key findings
- The sensor achieves a maximum fill factor of 13.4% and a peak photon detection probability of 27% at 3.3V excess bias.
- Median dark count rate is 2.0 cps, with timing jitter in gating length of 120ps and position skew of 410ps.
- The sensor enables depth resolution with a 5.4mm least significant bit (LSB) and precision better than 7.8mm over a 2m range.
- Extended dynamic range is demonstrated through dual exposure operation, allowing detection of both bright and dim objects in the same scene.
- Spatially overlapped multi-object detection is experimentally demonstrated in single-photon time-gated ToF imaging for the first time.
- The sensor operates at 24kfps with 3.8ns time-gating, marking the first 1-megapixel SPAD camera with such performance.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.