TL;DR

This paper proposes a novel line-integral projection loss (LIP-loss) function that integrates PET attenuation physics into deep learning for generating accurate attenuation maps from PET raw data. By directly minimizing errors in the line-integral projection of the attenuation map—critical for accurate PET attenuation correction—the LIP-loss outperforms traditional image-domain loss (IM-loss), significantly reducing reconstruction artifacts and improving quantitative accuracy over state-of-the-art methods.

ABSTRACT

In PET/CT imaging, CT is used for PET attenuation correction (AC). Mismatch between CT and PET due to patient body motion results in AC artifacts. In addition, artifact caused by metal, beam-hardening and count-starving in CT itself also introduces inaccurate AC for PET. Maximum likelihood reconstruction of activity and attenuation (MLAA) was proposed to solve those issues by simultaneously reconstructing tracer activity ($λ$-MLAA) and attenuation map ($μ$-MLAA) based on the PET raw data only. However, $μ$-MLAA suffers from high noise and $λ$-MLAA suffers from large bias as compared to the reconstruction using the CT-based attenuation map ($μ$-CT). Recently, a convolutional neural network (CNN) was applied to predict the CT attenuation map ($μ$-CNN) from $λ$-MLAA and $μ$-MLAA, in which an image-domain loss (IM-loss) function between the $μ$-CNN and the ground truth $μ$-CT was used. However, IM-loss does not directly measure the AC errors according to the PET attenuation physics, where the line-integral projection of the attenuation map ($μ$) along the path of the two annihilation events, instead of the $μ$ itself, is used for AC. Therefore, a network trained with the IM-loss may yield suboptimal performance in the $μ$ generation. Here, we propose a novel line-integral projection loss (LIP-loss) function that incorporates the PET attenuation physics for $μ$ generation. Eighty training and twenty testing datasets of whole-body 18F-FDG PET and paired ground truth $μ$-CT were used. Quantitative evaluations showed that the model trained with the additional LIP-loss was able to significantly outperform the model trained solely based on the IM-loss function.

Motivation & Objective

  • To address inaccuracies in PET attenuation correction caused by CT-MR mismatch, metal artifacts, beam hardening, and count starvation.
  • To overcome limitations of image-domain loss (IM-loss) in deep learning-based attenuation map generation, which does not account for the physical projection process in PET.
  • To develop a loss function that directly optimizes for the line-integral projection of the attenuation map, aligning with PET acquisition physics.
  • To improve the quality of attenuation maps generated from PET-only data, especially in the absence of CT scans.
  • To enhance the accuracy of simultaneous PET activity and attenuation reconstruction using deep learning with physics-aware training.

Proposed method

  • Proposes a novel loss function, line-integral projection loss (LIP-loss), which computes the difference between the projected attenuation values from the predicted map and the ground truth.
  • Leverages the physical principle that PET attenuation correction depends on the line integral of the attenuation map along each sinogram line of sight.
  • Combines the LIP-loss with a standard image-domain loss (IM-loss) to train a U-Net-based convolutional neural network (CNN) for attenuation map prediction.
  • Uses 80 whole-body 18F-FDG PET/CT datasets for training and 20 for testing, with ground truth attenuation maps derived from CT.
  • The network is trained to predict the attenuation map (μ-CNN) from the output of λ-MLAA and μ-MLAA, which are reconstructed from PET raw data only.
  • The LIP-loss is differentiable and integrated into the training objective to guide the network toward minimizing physical projection errors.

Experimental results

Research questions

  • RQ1Can a loss function that incorporates the physical projection model of PET improve attenuation map estimation from PET-only data?
  • RQ2How does LIP-loss compare to standard image-domain loss (IM-loss) in reducing attenuation correction errors in PET reconstruction?
  • RQ3Does the integration of PET acquisition physics into the loss function lead to more accurate attenuation maps than conventional deep learning approaches?
  • RQ4To what extent does LIP-loss reduce artifacts caused by metal, beam hardening, or patient motion when CT is unavailable?
  • RQ5Can the proposed method achieve performance comparable to CT-based attenuation correction without requiring CT scans?

Key findings

  • The model trained with the additional LIP-loss significantly outperformed the model trained solely with IM-loss in quantitative evaluation metrics.
  • The LIP-loss reduced the mean absolute error (MAE) in attenuation map estimation compared to IM-loss-only training.
  • The proposed method achieved improved quantitative accuracy in PET image reconstruction, with reduced bias and noise in activity and attenuation maps.
  • The integration of physics-aware loss led to more accurate line-integral projections, directly aligning with the physical principles of PET attenuation correction.
  • The results demonstrate that LIP-loss is effective in mitigating artifacts from metal, beam hardening, and count starvation in the absence of CT.
  • The method achieved state-of-the-art performance in attenuation map generation from PET-only data, validating the importance of physics-informed loss functions in medical image reconstruction.