Skip to main content
QUICK REVIEW

[Paper Review] A Pathologist-Annotated Dataset for Validating Artificial Intelligence: A Project Description and Pilot Study

Sarah Dudgeon, Si Wen|arXiv (Cornell University)|Oct 14, 2020
AI in cancer detectionComputer Science65 references26 citations
TL;DR

This paper presents a pathologist-annotated whole slide image dataset for validating AI algorithms in digital pathology, focusing on stromal tumor-infiltrating lymphocyte (sTIL) density estimation in breast cancer. Using a multi-platform workflow (digital and optical microscopy), 19 pathologists evaluated 1,645 regions of interest across 64 biopsies, revealing significant inter-reader variability and intra-case correlation, prompting refined sampling and statistical methods for future regulatory-grade validation studies.

ABSTRACT

Purpose: In this work, we present a collaboration to create a validation dataset of pathologist annotations for algorithms that process whole slide images (WSIs). We focus on data collection and evaluation of algorithm performance in the context of estimating the density of stromal tumor infiltrating lymphocytes (sTILs) in breast cancer. Methods: We digitized 64 glass slides of hematoxylin- and eosin-stained ductal carcinoma core biopsies prepared at a single clinical site. We created training materials and workflows to crowdsource pathologist image annotations on two modes: an optical microscope and two digital platforms. The workflows collect the ROI type, a decision on whether the ROI is appropriate for estimating the density of sTILs, and if appropriate, the sTIL density value for that ROI. Results: The pilot study yielded an abundant number of cases with nominal sTIL infiltration. Furthermore, we found that the sTIL densities are correlated within a case, and there is notable pathologist variability. Consequently, we outline plans to improve our ROI and case sampling methods. We also outline statistical methods to account for ROI correlations within a case and pathologist variability when validating an algorithm. Conclusion: We have built workflows for efficient data collection and tested them in a pilot study. As we prepare for pivotal studies, we will consider what it will take for the dataset to be fit for a regulatory purpose: study size, patient population, and pathologist training and qualifications. To this end, we will elicit feedback from the FDA via the Medical Device Development Tool program and from the broader digital pathology and AI community. Ultimately, we intend to share the dataset, statistical methods, and lessons learned.

Motivation & Objective

  • To address the critical lack of standardized reference data (ground truth) for validating AI algorithms in medical image analysis.
  • To develop a scalable, multi-platform workflow for collecting pathologist annotations on whole slide images (WSIs) for sTIL density estimation.
  • To evaluate inter-reader variability and intra-case correlation in sTIL assessments to inform future study design for regulatory validation.
  • To establish a foundation for a fit-for-regulatory-purpose dataset by refining sampling, training, and statistical methods based on pilot data.

Proposed method

  • Digitized 64 hematoxylin- and eosin-stained ductal carcinoma core biopsies from a single clinical site into whole slide images.
  • Selected 10 regions of interest (ROIs) per slide for evaluation, ensuring representative sampling across tumor and stromal areas.
  • Implemented a crowdsourced annotation workflow across two digital platforms (eeDAP, caMicroscope) and one optical microscope platform.
  • Collected annotations on ROI type, appropriateness for sTIL density estimation, and sTIL density values using standardized training materials.
  • Harmonized and cleaned heterogeneous raw data from different platforms into unified data frames using custom scripts.
  • Planned statistical analysis to account for intra-case correlation and inter-reader variability, including simulation studies and feedback from FDA’s Medical Device Development Tool (MDDT) program.

Experimental results

Research questions

  • RQ1How can a scalable, multi-platform workflow be designed to collect high-quality pathologist annotations on whole slide images for AI validation?
  • RQ2What level of inter-reader variability exists in sTIL density estimation, and how does it affect algorithm validation?
  • RQ3To what extent are sTIL density estimates correlated within a single patient case, and how should this be modeled statistically?
  • RQ4What training and qualification standards are needed to reduce pathologist variability and improve data quality for regulatory use?
  • RQ5How can performance metrics like RMSE be interpreted when pathologist variability may contribute to bias?

Key findings

  • A total of 1,645 ROI evaluations were completed by 19 pathologists in a 10-hour live data collection event, demonstrating the feasibility of high-throughput truthing.
  • The pilot study yielded abundant cases with nominal sTIL infiltration, providing sufficient data for statistical modeling.
  • Significant intra-case correlation was observed in sTIL density estimates, indicating that ROIs from the same case are not statistically independent.
  • Substantial inter-reader variability was identified, suggesting that pathologist expertise and training require standardization for reliable reference standards.
  • The study revealed that performance metrics like RMSE may be confounded by pathologist bias, warranting the use of ordinal correlation metrics such as Spearman’s rho or Kendall’s tau.
  • The team plans to enhance training with feedback loops and proficiency testing using pilot data to reduce variability and improve data quality for regulatory applications.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.