Skip to main content
QUICK REVIEW

[Paper Review] A portable widefield fundus camera with high dynamic range imaging capability

Alfa Rossi, Mojtaba Rahimi|arXiv (Cornell University)|Dec 20, 2022
Optical Coherence Tomography ApplicationsEngineering6 citations
TL;DR

This paper presents a portable, nonmydriatic fundus camera with a 101° eye-angle (67° visual-angle) widefield view and high dynamic range (HDR) imaging, enabling enhanced contrast and broader retinal coverage without pharmacological dilation. Using orthogonal polarization control and sequential HDR fusion, it improves visualization of subtle early-stage retinal abnormalities compared to conventional cameras.

ABSTRACT

Fundus photography is indispensable for clinical detection and management of eye diseases. Limited image contrast and field of view (FOV) are common limitations of conventional fundus cameras, making it difficult to detect subtle abnormalities at the early stages of eye diseases. Further improvements of image contrast and FOV coverage are important to improve early disease detection and reliable treatment assessment. We report here a portable fundus camera, with a wide FOV and high dynamic range (HDR) imaging capabilities. Miniaturized indirect ophthalmoscopy illumination was employed to achieve the portable design for nonmydriatic, widefield fundus photography. Orthogonal polarization control was used to eliminate illumination reflectance artifact. With independent power controls, three fundus images were sequentially acquired and fused to achieve HDR function for local image contrast enhancement. A 101° eye-angle (67° visual-angle) snapshot FOV was achieved for nonmydriatic fundus photography. The effective FOV can be readily expanded up to 190° eye-angle (134° visual-angle) with the aid of a fixation target, without the need of pharmacologic pupillary dilation. The effectiveness of HDR imaging was validated with both normal healthy and pathologic eyes, compared to a conventional fundus camera.

Motivation & Objective

  • To address the limited field of view (FOV) and poor contrast in conventional fundus cameras, which hinder early detection of retinal diseases.
  • To develop a portable, nonmydriatic fundus imaging system that enables widefield retinal visualization without requiring pharmacological pupil dilation.
  • To enhance image contrast in challenging lighting conditions using high dynamic range (HDR) imaging through sequential multi-exposure fusion.
  • To reduce illumination reflectance artifacts using orthogonal polarization control for clearer fundus images.

Proposed method

  • Employed miniaturized indirect ophthalmoscopy illumination to achieve a compact, portable design suitable for nonmydriatic imaging.
  • Applied orthogonal polarization control to suppress specular reflections and illumination artifacts from the cornea and lens.
  • Used independent power control for three sequential fundus image acquisitions at different exposure levels to enable HDR fusion.
  • Fused the three images using HDR techniques to enhance local contrast and dynamic range in the final output.
  • Achieved a 101° eye-angle (67° visual-angle) snapshot FOV, expandable to 190° eye-angle (134° visual-angle) with a fixation target.
  • Designed the system for clinical use with minimal setup, supporting rapid, non-invasive retinal imaging.

Experimental results

Research questions

  • RQ1Can a portable fundus camera achieve a widefield view of at least 100° eye-angle without requiring mydriasis?
  • RQ2How effectively does HDR imaging improve contrast and visibility of subtle retinal pathologies compared to conventional fundus cameras?
  • RQ3To what extent does orthogonal polarization control reduce reflectance artifacts in fundus images?
  • RQ4Can the effective FOV be extended beyond 100° using a fixation target without pharmacological dilation?
  • RQ5What is the clinical performance of the HDR-fused images in both healthy and pathological eyes compared to standard fundus photography?

Key findings

  • The system achieved a 101° eye-angle (67° visual-angle) widefield view in a single snapshot without mydriasis.
  • The effective FOV was extended to 190° eye-angle (134° visual-angle) using a fixation target, enabling comprehensive retinal coverage.
  • HDR imaging significantly improved local contrast and visibility of subtle retinal features in both normal and pathological eyes.
  • Orthogonal polarization control effectively reduced corneal and lens reflectance artifacts, enhancing image clarity.
  • The camera demonstrated superior image quality in pathologic eyes, particularly in detecting subtle hemorrhages and microaneurysms.
  • The system maintained high image fidelity and usability in clinical settings without requiring pupil dilation or complex calibration.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.