[Paper Review] A Reliable IoT-Based Embedded Health Care System for Diabetic Patients
This paper presents an IoT-based embedded healthcare system for diabetic patients using an Alaris 8100 insulin pump, Keil LPC-1768 microcontroller, and cloud integration. It ensures reliability through SHA-256 hashing and SSH encryption, achieving 99.3% availability and sub-millisecond processing speed for health records.
This paper introduces a reliable health care system for diabetic patients based on the Internet of Things technology. A diabetic health care system with a hardware implementation is presented. The proposed work employs Alaris 8100 infusion pump, Keil LPC-1768 board, and IoT-cloud to monitor the diabetic patients. The security of diabetic data over the cloud and the communication channel between health care system components are considered as part of the main contributions of this work. Moreover, an easy way to control and monitor the diabetic insulin pump is implemented. The \mbox{patient extquotesingle s} records are stored in the cloud using the Keil board that is connected to the infusion pump. The reliability of the proposed scheme is accomplished by testing the system for five performance characteristics (availability, confidentiality, integrity, authentication, and authorization). The Kiel board is embedded with Ethernet port and Cortex-M3 micro-controller that controls the insulin infusion pump. The secure hash algorithm and secure socket shell are employed to achieve the reliability components of the proposed scheme. The results show that the proposed design is reliable, secure and authentic according to different test experiments and a case study of the Markov model. Moreover, a 99.3\% availability probability has been achieved after analyzing the case study.
Motivation & Objective
- To design a reliable, secure, and real-time IoT-based healthcare system for diabetic patients.
- To address critical security challenges in cloud-stored diabetic health records, including confidentiality, integrity, and authentication.
- To enable remote monitoring and control of insulin infusion pumps with strong access control and data integrity.
- To evaluate system reliability using Markov modeling and performance testing across availability, confidentiality, integrity, authentication, and authorization.
- To implement a hardware-software stack that ensures low-latency, secure data transmission between patient devices, cloud, and caregivers.
Proposed method
- Utilizes Keil LPC-1768 board with Cortex-M3 microcontroller and Ethernet interface for real-time data processing and communication.
- Integrates Alaris 8100 insulin pump with the embedded system for automated insulin delivery control.
- Employs SHA-256 for message integrity and data authenticity, ensuring tamper detection via cryptographic hashing.
- Applies SSH encryption for secure communication channels between system components and the cloud.
- Implements access control via authentication and authorization mechanisms to restrict data access to authorized entities only.
- Uses Markov chain modeling to analyze system reliability, with failure and recovery rates derived from empirical data.
Experimental results
Research questions
- RQ1How can an IoT-based embedded system ensure high availability and reliability in monitoring diabetic patients?
- RQ2To what extent can SHA-256 and SSH encryption jointly guarantee confidentiality, integrity, and authentication of patient health data?
- RQ3What is the end-to-end processing latency of the system for real-time health record handling?
- RQ4How does the system maintain secure remote control of insulin infusion pumps without compromising patient safety?
- RQ5What is the probability of system failure or downtime under real-world operational conditions?
Key findings
- The system achieved a 99.3% probability of remaining in the normal operation state, as determined by Markov model analysis.
- The average processing time for 70 diabetic health record samples was 5.8 × 10⁻⁴ seconds (0.58 milliseconds), with low standard deviation indicating consistent performance.
- The system successfully enforced all five reliability characteristics: availability, confidentiality, integrity, authentication, and authorization.
- No successful collision attacks were found against SHA-256 in the implementation, confirming strong data integrity.
- The use of SSH for communication and SHA-256 for hashing effectively prevented unauthorized access and data tampering.
- The system supports remote monitoring and control of insulin pumps with secure, authenticated access, enhancing patient care efficiency.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.