[Paper Review] AdaIN-Switchable CycleGAN for Efficient Unsupervised Low-Dose CT Denoising
This paper proposes AdaIN-Switchable CycleGAN, a single-generator unsupervised deep learning framework for low-dose CT denoising that uses adaptive instance normalization (AdaIN) to switch between noise reduction and noise generation within one network. By eliminating the need for a separate auxiliary generator, the method reduces parameters by ~50% and improves training stability, achieving superior PSNR (30.87 dB) and SSIM (0.6605) compared to prior cycleGAN methods.
Recently, deep learning approaches have been extensively studied for low-dose CT denoising thanks to its superior performance despite the fast computational time. In particular, cycleGAN has been demonstrated as a powerful unsupervised learning scheme to improve the low-dose CT image quality without requiring matched high-dose reference data. Unfortunately, one of the main limitations of the cycleGAN approach is that it requires two deep neural network generators at the training phase, although only one of them is used at the inference phase. The secondary auxiliary generator is needed to enforce the cycle-consistency, but the additional memory requirement and increases of the learnable parameters are the main huddles for cycleGAN training. To address this issue, here we propose a novel cycleGAN architecture using a single switchable generator. In particular, a single generator is implemented using adaptive instance normalization (AdaIN) layers so that the baseline generator converting a low-dose CT image to a routine-dose CT image can be switched to a generator converting high-dose to low-dose by simply changing the AdaIN code. Thanks to the shared baseline network, the additional memory requirement and weight increases are minimized, and the training can be done more stably even with small training data. Experimental results show that the proposed method outperforms the previous cycleGAN approaches while using only about half the parameters.
Motivation & Objective
- To address the high memory and parameter overhead of conventional CycleGAN, which requires two separate generators despite only one being used at inference.
- To enable stable training of low-dose CT denoising networks with limited datasets by minimizing the number of trainable parameters.
- To improve image quality in unsupervised low-dose CT denoising without requiring paired high-dose reference images.
- To explore the use of wavelet domain processing and identity loss to preserve anatomical structures and reduce artifacts.
Proposed method
- A single generator is implemented using adaptive instance normalization (AdaIN) layers, allowing it to switch roles between converting low-dose to high-dose and high-dose to low-dose CT images by changing the AdaIN code.
- The AdaIN code is generated by a lightweight code generator network, which has significantly fewer parameters than the main image generator.
- The network is trained using adversarial loss, cycle consistency loss, and identity loss to ensure realistic image translation and feature preservation.
- Wavelet transform is applied to decompose low-dose CT images into low- and high-frequency subbands, with the network focusing on learning noise patterns in high-frequency components.
- The identity loss is applied to preserve structural details by minimizing the difference between input and reconstructed images when the input is already in the target domain.
- The method uses a single generator with shared backbone weights, drastically reducing the total number of parameters compared to standard CycleGAN.
Experimental results
Research questions
- RQ1Can a single generator with AdaIN switching replace two separate generators in CycleGAN for low-dose CT denoising while maintaining performance?
- RQ2Does reducing the number of parameters through a shared generator architecture improve training stability, especially with limited training data?
- RQ3How does wavelet domain processing compare to image domain processing in preserving image quality and reducing artifacts in low-dose CT denoising?
- RQ4What is the contribution of identity loss and wavelet residual learning to the suppression of artificial features in reconstructed images?
Key findings
- The proposed method achieves a PSNR of 30.87 dB and SSIM of 0.6605, outperforming the WavCycleGAN (PSNR: 30.40 dB, SSIM: 0.6279).
- With only 6.18 million total parameters, the method uses approximately half the parameters of the WavCycleGAN (11.82 million), despite comparable or better performance.
- The method shows graceful degradation with reduced training data: PSNR dropped from 30.87 dB to 30.39 dB at 10% of the training set, while WavCycleGAN dropped to 28.98 dB.
- Ablation studies confirm that both wavelet residual learning and identity loss are essential—removing either leads to visible artifacts and edge distortions in difference images.
- The use of AdaIN enables effective generator switching with minimal additional parameters, significantly improving training efficiency and stability.
- The method preserves anatomical structures better than baseline approaches, as shown by reduced intensity variations and sharper edges in reconstructed images.