Skip to main content
QUICK REVIEW

[Paper Review] Allan Variance Analysis as Useful Tool to Determine Noise in Various Single-Molecule Setups

Fabian Czerwinski, Andrew C. Richardson|ArXiv.org|Aug 31, 2009
Orbital Angular Momentum in OpticsPhysics and Astronomy17 references5 citations
TL;DR

This paper proposes Allan variance analysis as a superior method to quantify low-frequency noise and drift in optical tweezers setups, especially for single-molecule experiments. It enables real-time optimization of sampling time and data acquisition length, demonstrating effectiveness for both micron-sized spheres and asymmetric nanorods, revealing that noise contributions vary significantly with geometry and trapping stiffness.

ABSTRACT

One limitation on the performance of optical traps is the noise inherently present in every setup. Therefore, it is the desire of most experimentalists to minimize and possibly eliminate noise from their optical trapping experiments. A step in this direction is to quantify the actual noise in the system and to evaluate how much each particular component contributes to the overall noise. For this purpose we present Allan variance analysis as a straightforward method. In particular, it allows for judging the impact of drift which gives rise to low-frequency noise, which is extremely difficult to pinpoint by other methods. We show how to determine the optimal sampling time for calibration, the optimal number of data points for a desired experiment, and we provide measurements of how much accuracy is gained by acquiring additional data points. Allan variances of both micrometer-sized spheres and asymmetric nanometer-sized rods are considered.

Motivation & Objective

  • To address the challenge of quantifying low-frequency noise and drift in optical trapping experiments, which limits measurement accuracy in single-molecule force spectroscopy.
  • To provide a practical, on-the-fly method for evaluating noise contributions from individual components such as piezo stages, detection systems, and chamber geometry.
  • To determine optimal sampling times and data point counts for accurate calibration in both spherical and asymmetric nanoscale particles.
  • To extend the utility of Allan variance beyond spherical particles to include anisotropic nanorods, where noise is directionally dependent.

Proposed method

  • Apply Allan variance to positional time series of optically trapped particles to quantify noise, particularly drift, which conventional variance and Fourier analysis fail to converge on.
  • Use the Allan variance as a function of integration time to identify the optimal measurement interval for calibration, minimizing noise impact.
  • Compare Allan variance results with simulated data and normal variance to validate its ability to detect drift and low-frequency noise.
  • Measure and analyze noise contributions from photodiode-based detection systems, piezo stages, acoustic noise, and chamber geometry using Allan variance.
  • Analyze asymmetric gold nanorods (63.8 ± 7.4 nm long, 37.3 ± 5.0 nm wide) by computing Allan variance along both long and short axes to assess directional noise sensitivity.
  • Use the thermal limit (Equation 4) as a reference to evaluate how close experimental Allan variances are to the fundamental noise floor.

Experimental results

Research questions

  • RQ1How can low-frequency noise and drift in optical tweezers be quantified more effectively than with traditional Fourier or variance analysis?
  • RQ2What is the optimal sampling time for calibration in optical trapping experiments, and how does it depend on particle size and trap stiffness?
  • RQ3How do noise contributions from piezo stages, detection systems, and chamber geometry affect measurement accuracy in single-molecule setups?
  • RQ4To what extent does the shape and alignment of asymmetric nanorods influence the noise spectrum in optical trapping?
  • RQ5Can Allan variance analysis be effectively applied to nanoscale, non-spherical particles such as gold nanorods?

Key findings

  • Allan variance successfully identifies and quantifies low-frequency drift, which conventional variance and Fourier analysis fail to converge on, especially in long time series.
  • The optimal measurement interval for calibration is on the order of 0.1 seconds for gold nanorods, significantly shorter than the ~1 second intervals optimal for larger polystyrene spheres.
  • For gold nanorods, the Allan variance is lower along the long axis (κ = 2.3 pN/μm) than along the short axis (κ = 2.1 pN/μm), indicating directionally dependent noise due to anisotropic polarizability.
  • The piezo stage contributes significant broadband noise, visible as a rise in Allan variance when active, and its noise is clearly distinguishable from the system's thermal limit.
  • The geometry of the sample chamber (30 mm × 5 mm) may contribute to distinct peaks in the Allan variance at long measurement times, suggesting environmental constraints on noise.
  • Normal variance fails to reveal optimal measurement times or drift effects, while Allan variance clearly indicates the minimum noise regime and optimal data acquisition length.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.