Skip to main content
QUICK REVIEW

[Paper Review] Almost perfect phase retrieval in the Fresnel domain by a modified Gerchberg-Saxton algorithm

Soheil Mehrabkhani, Melvin Kuester|arXiv (Cornell University)|Nov 2, 2017
Advanced X-ray Imaging TechniquesPhysics and Astronomy2 citations
TL;DR

This paper proposes a modified Gerchberg-Saxton algorithm (MGSA) for phase retrieval in the Fresnel domain, addressing padding artifacts caused by computational width exceeding physical image dimensions. By introducing a simple, efficient padding solution, the method achieves almost perfect phase retrieval while preserving the time efficiency of the original algorithm.

ABSTRACT

The modified Gerchberg-Saxton algorithm (MGSA) is one of the standard methods for phase retrieval. In this work we apply the MGSA in the paraxial domain. For three given physical parameters - i.e. wavelength, propagation distance and pixel size the computational width in the Fresnel-Transform is fixed. This width can be larger than the real dimension of the input or output images. Consequently, it can induce a padding around the real input and output without given amplitude (intensity) values. To solve this problem, we propose a very simple and efficient solution and compare it to other approaches. We demonstrate that the new modified GSA provides almost perfect results without losing the time efficiency of the simplest method.

Motivation & Objective

  • To address the issue of artificial padding in the Fresnel transform when computational width exceeds physical image dimensions.
  • To maintain the time efficiency of the standard Gerchberg-Saxton algorithm during phase retrieval.
  • To improve phase retrieval accuracy in the paraxial (Fresnel) domain by minimizing artifacts from unknown amplitude values in padded regions.
  • To provide a simple and effective solution for handling undefined intensity values in padded areas of input and output planes.

Proposed method

  • The modified Gerchberg-Saxton algorithm (MGSA) is applied in the paraxial (Fresnel) domain using fixed physical parameters: wavelength, propagation distance, and pixel size.
  • The computational width in the Fresnel transform is determined by these parameters and may exceed the actual image dimensions, leading to padding with unknown amplitude values.
  • A novel, simple, and efficient method is introduced to handle the padding regions where no intensity values are available.
  • The algorithm iteratively enforces amplitude constraints in the input and output planes while propagating between them via the Fresnel transform.
  • The solution avoids complex optimization or additional constraints by leveraging the inherent structure of the MGSA framework.
  • The method maintains computational efficiency by avoiding iterative refinement of padding values, relying instead on a direct handling strategy.

Experimental results

Research questions

  • RQ1How can padding artifacts be minimized in phase retrieval when the computational width exceeds the physical image size in the Fresnel domain?
  • RQ2Can a simple modification to the Gerchberg-Saxton algorithm preserve time efficiency while achieving near-perfect phase retrieval?
  • RQ3What is the impact of unknown amplitude values in padded regions on phase retrieval accuracy, and how can it be effectively mitigated?
  • RQ4How does the proposed method compare in performance and efficiency to existing approaches for handling padding in phase retrieval?

Key findings

  • The proposed method achieves almost perfect phase retrieval results despite the presence of padding with unknown amplitude values.
  • The solution maintains the time efficiency of the original Gerchberg-Saxton algorithm without introducing computational overhead.
  • The method effectively suppresses artifacts caused by undefined intensity values in padded regions through a simple and direct approach.
  • Compared to other approaches, the proposed method provides superior accuracy while retaining computational simplicity.
  • The algorithm's performance is robust under fixed physical parameters (wavelength, propagation distance, pixel size), ensuring consistent results across different setups.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.