[Paper Review] An automated machine learning framework to optimize radiomics model construction validated on twelve clinical applications
This paper proposes an automated machine learning framework that fully optimizes radiomics workflow construction across twelve clinical applications by systematically evaluating diverse preprocessing, feature extraction, and modeling pipelines. The method achieves competitive performance—ranging from AUC 0.45 to 0.87—outperforming human expert heuristics and baseline radiomics, while ensuring reproducibility through open-source software and datasets.
Predicting clinical outcomes from medical images using quantitative features (``radiomics'') requires many method design choices, Currently, in new clinical applications, finding the optimal radiomics method out of the wide range of methods relies on a manual, heuristic trial-and-error process. We introduce a novel automated framework that optimizes radiomics workflow construction per application by standardizing the radiomics workflow in modular components, including a large collection of algorithms for each component, and formulating a combined algorithm selection and hyperparameter optimization problem. To solve it, we employ automated machine learning through two strategies (random search and Bayesian optimization) and three ensembling approaches. Results show that a medium-sized random search and straight-forward ensembling perform similar to more advanced methods while being more efficient. Validated across twelve clinical applications, our approach outperforms both a radiomics baseline and human experts. Concluding, our framework improves and streamlines radiomics research by fully automatically optimizing radiomics workflow construction. To facilitate reproducibility, we publicly release six datasets, software of the method, and code to reproduce this study.
Motivation & Objective
- To address the lack of reproducibility and high manual effort in radiomics model development across new clinical applications.
- To reduce reliance on expert-driven, heuristic trial-and-error processes for selecting optimal radiomics pipelines.
- To streamline radiomics biomarker discovery by automating the end-to-end workflow optimization process.
- To improve performance and generalization by systematically evaluating diverse combinations of preprocessing, feature extraction, and modeling techniques.
- To promote reproducibility and clinical translation by publicly releasing software, code, and six datasets.
Proposed method
- Formulates radiomics as a modular workflow with interchangeable components for preprocessing, feature extraction, and modeling.
- Employs a random search strategy combined with model ensembling to explore and optimize the hyperparameter space of radiomics pipelines.
- Integrates a comprehensive library of standard algorithms for each workflow component, including intensity, texture, shape, and wavelet-based features.
- Uses nested cross-validation to evaluate pipeline performance and prevent overfitting during hyperparameter search.
- Applies automated feature selection and model calibration to enhance generalization and clinical interpretability.
- Deploys a scalable software pipeline built on open-source tools, enabling full reproducibility and extensibility.
Experimental results
Research questions
- RQ1Can automated machine learning outperform manual, expert-driven radiomics pipeline selection in terms of predictive performance and reproducibility?
- RQ2How does the proposed framework compare to Bayesian optimization and other advanced ensemble methods in radiomics model optimization?
- RQ3What level of performance can be achieved across diverse clinical applications using a fully automated, modular radiomics workflow?
- RQ4To what extent does the framework reduce the need for domain expertise and manual tuning in new radiomics applications?
- RQ5Can the framework be generalized across heterogeneous imaging modalities and clinical conditions while maintaining robust performance?
Key findings
- The framework achieved AUCs ranging from 0.45 to 0.87 across twelve clinical applications, with Alzheimer’s disease showing the highest performance at 0.87.
- In liposarcoma, the framework achieved an AUC of 0.83, demonstrating strong performance in soft-tissue sarcoma prediction.
- For desmoid-type fibromatosis, the method reached an AUC of 0.82, indicating high predictive accuracy in rare fibroproliferative tumors.
- The framework outperformed a standard radiomics baseline and matched or exceeded the performance of Bayesian optimization and advanced ensemble methods.
- The method demonstrated robustness across diverse imaging types (CT, MRI, PET) and clinical conditions, including cancer, neurodegenerative, and fibrotic diseases.
- The framework’s performance was consistently competitive with expert-optimized pipelines, significantly reducing manual effort and improving reproducibility.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.