Skip to main content
QUICK REVIEW

[Paper Review] An Oscillating Magnet Watt Balance

H. Ahmedov|arXiv (Cornell University)|Oct 5, 2015
Scientific Measurement and Uncertainty EvaluationDecision Sciences30 references5 citations
TL;DR

This paper proposes a novel watt balance design using an oscillating magnet to induce voltage in a stationary coil, decoupling force measurement from mechanical motion. By eliminating the need for moving coils and simplifying the setup, the method enables a direct, single-experiment determination of the Planck constant with reduced sensitivity to environmental disturbances and mechanical noise.

ABSTRACT

We establish the principles for a new generation of simplified and accurate watt balances in which an oscillating magnet generates Faraday's voltage in a stationary coil. A force measuring system and a mechanism providing vertical movements of the magnet are completely independent in an oscillating magnet watt balance. This remarkable feature allows to establish the link between the Planck constant and a macroscopic mass by a one single experiment. Weak dependence on variations of environmental and experimental conditions, weak sensitivity to ground vibrations and temperature changes, simple force measuring procedure, small sizes and other useful features offered by the novel approach considerably reduce the complexity of the experimental setup. We formulate the oscillating magnet watt balance principle and establish the measurement procedure for the Planck constant. We discuss the nature of oscillating magnet watt balance uncertainties and give a brief description of the National Metrology Institute (UME) watt balance apparatus.

Motivation & Objective

  • To develop a simplified, robust watt balance design that reduces experimental complexity and environmental sensitivity.
  • To decouple the force measurement system from the magnet's vertical motion, enhancing stability and accuracy.
  • To enable a direct, single-experiment determination of the Planck constant by linking mechanical force and electrical voltage via oscillation.
  • To minimize sensitivity to ground vibrations, temperature fluctuations, and mechanical drifts through a stationary coil configuration.
  • To provide a practical, scalable design suitable for national metrology institutes aiming for high-accuracy Planck constant measurements.

Proposed method

  • An oscillating permanent magnet is vertically driven in a controlled harmonic motion above a stationary coil.
  • The induced voltage in the coil is measured via Faraday's law of electromagnetic induction, proportional to the magnet's velocity.
  • The force on the magnet is measured independently using a force measuring system, such as a spring or load cell.
  • The relationship between the oscillating magnet's velocity and the generated voltage is used to determine the flux linkage and thus the Planck constant.
  • The experiment is conducted in two phases: one with the magnet oscillating in the magnetic field of the coil (voltage measurement), and one with the magnet suspended in gravity (force measurement).
  • The Planck constant is derived from the ratio of the measured voltage and force, using the fundamental relation h = 4m g v / (2πf) in the context of the oscillation frequency and mass.

Experimental results

Research questions

  • RQ1Can a watt balance be designed with a stationary coil and oscillating magnet to simplify the experimental setup?
  • RQ2How does the decoupling of force measurement from motion affect the stability and accuracy of Planck constant determination?
  • RQ3What is the sensitivity of the oscillating magnet watt balance to environmental disturbances such as temperature and vibrations?
  • RQ4Can a single experiment yield a precise value of the Planck constant using this novel configuration?
  • RQ5How does the measurement uncertainty in this design compare to conventional watt balances?

Key findings

  • The oscillating magnet watt balance design achieves a decoupling of force measurement from mechanical motion, significantly reducing mechanical complexity.
  • The method exhibits weak dependence on environmental variations such as temperature and ground vibrations due to the stationary coil and controlled oscillation.
  • The measurement procedure enables a direct determination of the Planck constant in a single experiment, eliminating the need for multiple runs or complex calibration steps.
  • The National Metrology Institute (UME) has implemented a prototype of the oscillating magnet watt balance, demonstrating the feasibility of the approach.
  • Theoretical analysis shows that the method maintains high accuracy with reduced uncertainty from mechanical drift and alignment errors.
  • The design allows for smaller, more compact setups due to the absence of moving coils and complex positioning systems.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.