[Paper Review] Analog read-out of the RPCs in the ARGO-YBJ experiment

M. Iacovacci, S. Catalanotti|arXiv (Cornell University)|May 29, 2003
Particle Detector Development and PerformancePhysics and Astronomy4 citations
TL;DR

This paper presents a prototype analog charge read-out system for Resistive Plate Chambers (RPCs) in the ARGO-YBJ experiment, using a peak-and-hold circuit to measure particle density up to 600–700 particles/m². The system achieves linear response and low noise, enabling extended dynamic range beyond digital strip read-out for studying cosmic ray showers near the knee region of the spectrum.

ABSTRACT

The ARGO-YBJ experiment, currently under construction at the Yangbaijing Laboratory (4300 m a.s.l.), consists of a single layer of about 2000 Resistive Plate Chambers (RPCs) for a total instrumented area of about 6700 m^2. The digital read-out, performed by means of pick-up electrodes 6.7 X 62 cm^2 ('strips'), allows one to measure the particle number of small size showers. To extend the size range up to the knee region it is necessary to implement the charge read-out of the detector chambers. In order to achieve this goal each RPC has been instrumented with two large size pads of dimensions 140 X 125 cm^2. In this paper the performance of the prototype circuit devoted to the charge read-out is reported.

Motivation & Objective

  • Extend the dynamic range of the ARGO-YBJ experiment beyond the limitations of digital strip read-out for high-energy cosmic ray showers.
  • Enable accurate measurement of particle density in large-size showers, particularly near the knee region of the cosmic ray spectrum.
  • Develop and test a charge-measuring circuit capable of handling high-amplitude signals from large-area RPC pads.
  • Integrate analog read-out with existing digital systems for future hybrid data acquisition.
  • Prepare for full deployment by validating performance and dynamic range before installation on 100 m² of the detector.

Proposed method

  • A unity-gain peak-and-hold (PH) circuit is used to capture and hold the maximum amplitude of signals from 140×125 cm² Big Pads on RPCs.
  • The PH circuit tracks signals starting from 30 mV, with a 1.5 µs timing gate to capture peak values.
  • A 12-bit ADC with 1.2 µs conversion time digitizes the PH output, synchronized with a trigger signal.
  • The system is tested with a digital pulse generator replicating m.i.p. signals on the Big Pad, with variable trigger delays up to 500 ns.
  • The circuit is housed on a VME crate with separate boards for PH and ADC to minimize noise coupling.
  • Signal linearity and noise performance are evaluated across a 100 mV to 6 V input range, corresponding to 1–700 particles/m².

Experimental results

Research questions

  • RQ1Can a prototype analog charge read-out system extend the dynamic range of ARGO-YBJ RPCs beyond the digital strip read-out limit?
  • RQ2How linear and stable is the charge measurement response across a wide dynamic range of particle densities?
  • RQ3What is the impact of trigger delay jitter on the accuracy of particle counting in the analog system?
  • RQ4Does the system maintain low noise and reliable performance under real detector conditions?
  • RQ5How well can the analog system be calibrated and intercalibrated with the existing digital read-out at low particle densities?

Key findings

  • The prototype charge meter circuit demonstrates excellent linearity from 100 mV to 6 V input, corresponding to 600–700 particles/m², with a mean signal of ~6 mV per m.i.p.
  • The system achieves a dynamic range of 600–700 particles/m², significantly extending beyond the digital strip read-out capability for high-energy showers.
  • The peak-and-hold circuit maintains a stable output with a discharge rate of ~6 mV/µs, introducing a maximum error of one particle in counting due to trigger jitter.
  • The circuit shows no appreciable noise from the VME power supply, ensuring clean signal acquisition.
  • The calibration curve remains linear across all tested trigger delay times (100, 300, 500 ns), indicating robustness to timing variations.
  • No saturation or non-linearity is observed below 6 V input, confirming the system's suitability for high-flux events.