TL;DR

AnatomyNet is an end-to-end, atlas-free 3D squeeze-and-excitation U-Net that enables fast, fully automated whole-volume segmentation of nine head and neck organs-at-risk (OARs) in CT scans. It achieves a 3.3% average improvement in Dice similarity coefficient (DSC) over state-of-the-art methods while segmenting a full volume in just 0.12 seconds.

ABSTRACT

Purpose: Radiation therapy (RT) is a common treatment for head and neck (HaN) cancer where therapists are often required to manually delineate boundaries of the organs-at-risks (OARs). The radiation therapy planning is time-consuming as each computed tomography (CT) volumetric data set typically consists of hundreds to thousands of slices and needs to be individually inspected. Automated head and neck anatomical segmentation provides a way to speed up and improve the reproducibility of radiation therapy planning. Previous work on anatomical segmentation is primarily based on atlas registrations, which takes up to hours for one patient and requires sophisticated atlas creation. In this work, we propose the AnatomyNet, an end-to-end and atlas-free three dimensional squeeze-and-excitation U-Net (3D SE U-Net), for fast and fully automated whole-volume HaN anatomical segmentation. Methods: There are two main challenges for fully automated HaN OARs segmentation: 1) challenge in segmenting small anatomies (i.e., optic chiasm and optic nerves) occupying only a few slices, and 2) training model with inconsistent data annotations with missing ground truth for some anatomical structures because of different RT planning. We propose the AnatomyNet that has one down-sampling layer with the trade-off between GPU memory and feature representation capacity, and 3D SE residual blocks for effective feature learning to alleviate these challenges. Moreover, we design a hybrid loss function with the Dice loss and the focal loss. The Dice loss is a class level distribution loss that depends less on the number of voxels in the anatomy, and the focal loss is designed to deal with highly unbalanced segmentation. For missing annotations, we propose masked loss and weighted loss for accurate and balanced weights updating in the learning of the AnatomyNet. Results: We collect 261 HaN CT images to train the AnatomyNet, and use MICCAI Head and Neck Auto Segmentation Challenge 2015 as the benchmark dataset to evaluate the performance of the AnatomyNet. The objective is to segment nine anatomies: brain stem, chiasm, mandible, optic nerve left, optic nerve right, parotid gland left, parotid gland right, submandibular gland left, and submandibular gland right. Compared to previous state-of-the-art methods for each anatomy from the MICCAI 2015 competition, the AnatomyNet increases Dice similarity coefficient (DSC) by 3.3% on average. The proposed AnatomyNet takes only 0.12 seconds on average to segment a whole-volume HaN CT image of an average dimension of 178 x 302 x 225. All the data and code will be available in https://github.com/wentaozhu/AnatomyNet-for-anatomical-segmentation.git. Conclusion: We propose an end-to-end, fast and fully automated deep convolutional network, AnatomyNet, for accurate and whole-volume HaN anatomical segmentation. The proposed AnatomyNet outperforms previous state-of-the-art methods on the benchmark dataset. Extensive experiments demonstrate the effectiveness and good generalization ability of the components in the AnatomyNet. Key words: Fast and fully automated anatomical segmentation, 3D squeeze-and-excitation U-Net (3D SE U-Net), radiation therapy, head and neck organ segmentation

Motivation & Objective

  • To address the time-consuming and inconsistent manual delineation of organs-at-risk (OARs) in head and neck (HaN) cancer radiation therapy planning.
  • To overcome challenges in segmenting small anatomical structures like the optic chiasm and optic nerves, which occupy only a few slices.
  • To handle inconsistent annotations in clinical data, including missing ground truth for some structures due to varying RT planning practices.
  • To develop a fully automated, end-to-end deep learning model that eliminates reliance on time-consuming atlas registration.

Proposed method

  • Proposes a 3D squeeze-and-excitation U-Net (3D SE U-Net) with a single down-sampling layer to balance GPU memory usage and feature representation capacity.
  • Employs 3D squeeze-and-excitation residual blocks to enhance feature learning by adaptively recalibrating channel-wise feature responses.
  • Introduces a hybrid loss function combining Dice loss for class-level distribution robustness and focal loss to address class imbalance in segmentation.
  • Designs a masked loss and weighted loss strategy to handle missing annotations by selectively updating gradients only on available ground truth regions.
  • Trains the model end-to-end on 261 HaN CT volumes with multi-structure annotations, using the MICCAI 2015 challenge dataset as benchmark.

Experimental results

Research questions

  • RQ1Can a deep learning model achieve fast, fully automated whole-volume segmentation of multiple head and neck OARs without relying on atlas registration?
  • RQ2How effective is the 3D squeeze-and-excitation U-Net architecture in segmenting small, low-visibility anatomical structures such as the optic chiasm?
  • RQ3To what extent can a hybrid loss function combining Dice and focal loss improve segmentation accuracy in the presence of class imbalance and missing annotations?
  • RQ4Does the proposed masked and weighted loss strategy effectively handle inconsistent clinical annotations with missing ground truth for certain structures?

Key findings

  • AnatomyNet achieves a 3.3% average improvement in Dice similarity coefficient (DSC) across nine head and neck OARs compared to state-of-the-art methods on the MICCAI 2015 benchmark.
  • The model segments an entire HaN CT volume (average size 178×302×225) in just 0.12 seconds, demonstrating high inference speed.
  • The 3D squeeze-and-excitation residual blocks significantly improve feature representation, especially for small and low-contrast structures like the optic nerves.
  • The hybrid loss function with Dice and focal loss components enhances segmentation performance on rare and imbalanced structures, particularly those with sparse annotations.
  • The masked and weighted loss strategy enables stable and accurate training even when some anatomical structures lack ground truth in the training data.
  • The model shows strong generalization ability, as validated across diverse clinical data with inconsistent annotation patterns.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.