Skip to main content
QUICK REVIEW

[Paper Review] Arbitrarily High-order Unconditionally Energy Stable Schemes for Gradient Flow Models Using the Scalar Auxiliary Variable Approach

Yuezheng Gong, Jia Zhao|arXiv (Cornell University)|Jul 9, 2019
Numerical methods for differential equationsMathematics46 references6 citations
TL;DR

This paper proposes the High-Order Scalar Auxiliary Variable (HSAV) method, a novel family of arbitrarily high-order time-accurate schemes for gradient flow models that preserve energy stability unconditionally. By combining the SAV approach with high-order time integrators, the method achieves optimal convergence rates and enables significantly larger time steps than existing SAV schemes, while maintaining unconditional energy stability and high accuracy across multiple benchmark models.

ABSTRACT

In this paper, we propose a novel family of high-order numerical schemes for the gradient flow models based on the scalar auxiliary variable (SAV) approach, which is named the high-order scalar auxiliary variable (HSAV) method. The newly proposed schemes could be shown to reach arbitrarily high order in time while preserving the energy dissipation law without any restriction on the time step size (i.e., unconditionally energy stable). The HSAV strategy is rather general that it does not depend on the specific expression of the effective free energy, such that it applies to a class of thermodynamically consistent gradient flow models arriving at semi-discrete high-order energy-stable schemes. We then employ the Fourier pseudospectral method for spatial discretization. The fully discrete schemes are also shown to be unconditionally energy stable. Furthermore, we present several numerical experiments on several widely-used gradient flow models, to demonstrate the accuracy, efficiency and unconditionally energy stability of the HSAV schemes. The numerical results verify that the HSAV schemes can reach the expected order of accuracy, and it allows a much larger time step size to reach the same accuracy than the standard SAV schemes.

Motivation & Objective

  • To develop a general framework for constructing arbitrarily high-order time-accurate numerical schemes for gradient flow models that preserve energy stability.
  • To overcome the limitation of existing SAV schemes, which are typically limited to second-order accuracy, by enabling higher-order temporal convergence.
  • To ensure unconditionally energy stability regardless of time step size, allowing efficient long-time simulations.
  • To extend the applicability of the SAV approach to a broad class of thermodynamically consistent gradient flow models without requiring specific forms of the free energy functional.
  • To demonstrate the method's efficiency and accuracy through numerical experiments on widely used models such as Allen-Cahn, Cahn-Hilliard, and MBE equations.

Proposed method

  • The HSAV method reformulates the original gradient flow model using the scalar auxiliary variable (SAV) approach, introducing an auxiliary variable to make the free energy quadratic in the new variables.
  • High-order time integration is achieved via a class of linearly implicit Runge-Kutta or multistep schemes (e.g., Gauss-Legendre or backward differentiation formulas) applied to the SAV-reformulated system.
  • The resulting semi-discrete scheme is proven to be unconditionally energy stable with respect to a modified free energy functional, ensuring energy decay at the discrete level.
  • Spatial discretization is performed using the Fourier pseudospectral method, which provides spectral accuracy in space and allows efficient computation via FFT.
  • The fully discrete scheme inherits the unconditional energy stability property due to the structure-preserving nature of the time integrator and the SAV reformulation.
  • The method is general and does not require assumptions on the specific form of the free energy functional, making it applicable to a wide range of gradient flow models.

Experimental results

Research questions

  • RQ1Can arbitrarily high-order time integration be combined with the SAV framework to achieve both high accuracy and unconditional energy stability in gradient flow simulations?
  • RQ2Does the proposed HSAV method maintain energy stability for large time steps across diverse gradient flow models, including Allen-Cahn, Cahn-Hilliard, and MBE models?
  • RQ3How does the numerical error and computational cost of the HSAV scheme compare to standard SAV schemes at the same accuracy level and time step size?
  • RQ4To what extent can the HSAV method allow larger time steps while preserving energy dissipation and achieving expected convergence rates?
  • RQ5Can the HSAV framework be generalized to other thermodynamically consistent models beyond the tested examples?

Key findings

  • The HSAV schemes achieve the expected order of accuracy in time, with 4th-order and 6th-order schemes demonstrating optimal convergence rates in time refinement studies.
  • The HSAV schemes exhibit dramatically smaller numerical errors—by several orders of magnitude—compared to the standard SAV-CN scheme at comparable time steps.
  • For the MBE model with slope selection, the 6th-order HSAV scheme accurately captures energy dissipation even with a time step of δt = 0.05, whereas the SAV-CN scheme requires δt = 10⁻⁴ for comparable accuracy.
  • The total CPU time for the 4th-order HSAV scheme with δt = 0.025 was only 79.45 seconds, compared to 672.39 seconds for the SAV-CN scheme with δt = 0.0001, demonstrating a 5–8x speedup.
  • Numerical solutions for the MBE model using the 4th-order HSAV scheme with δt = 0.025 produced morphologically consistent patterns that match known literature results, validating the method’s physical fidelity.
  • The HSAV method maintains unconditional energy stability across all tested models, with energy decreasing monotonically over time regardless of time step size.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.