TL;DR

This paper evaluates the potential of monolithic silicon pixel sensors, specifically the ATLASPix detector, for future space-based gamma-ray astrophysics missions. By testing its energy resolution with radioactive photon sources, the study demonstrates that analog output achieves 7.69% resolution at 5.89 keV and 7.27% at 30.1 keV—exceeding conservative mission requirements and indicating strong promise for Compton telescopes. The digital output, however, shows poor resolution, highlighting the need for redesign in future detectors like AstroPix V1.

ABSTRACT

This paper details preliminary photon measurements with the monolithic silicon detector ATLASPix, a pixel detector built and optimized for the CERN experiment ATLAS. The goal of this paper is to determine the promise of pixelated silicon in future space-based gamma-ray experiments. With this goal in mind, radioactive photon sources were used to determine the energy resolution and detector response of ATLASPix; these are novel measurements for ATLASPix, a detector built for a ground-based particle accelerator. As part of this project a new iteration of monolithic Si pixels, named AstroPix, have been created based on ATLASPix, and the eventual goal is to further optimize AstroPix for gamma-ray detection by constructing a prototype Compton telescope.The energy resolution of both the digital and analog output of ATLASPix is the focus of this paper, as it is a critical metric for Compton telescopes. It was found that with the analog output of the detector, the energyresolution of a single pixel was 7.69 +/- 0.13% at 5.89 keV and 7.27 +/- 1.18% at 30.1 keV, which exceeds the conservative baseline requirements of 10% resolution at 60 keV and is an encouraging start to an optimistic goal of<2% resolution at 60 keV. The digital output of the entire detector consistently yielded energy resolutions that exceeded 100% for different sources. The analog output of the monolithic silicon pixels indicates that thisis a promising technology for future gamma-ray missions, while the analysis of the digital output points to the need for a redesign of future photon-sensitive monolithic silicon pixel detectors.

Motivation & Objective

  • To assess the feasibility of monolithic silicon pixel sensors for future space-based gamma-ray missions.
  • To evaluate the energy resolution and detector response of the ATLASPix sensor, originally designed for particle physics, in a gamma-ray detection context.
  • To identify design improvements needed for future detectors to meet stringent energy resolution requirements for Compton telescopes.
  • To lay the foundation for developing AstroPix V1, a new-generation pixel sensor optimized for high-energy photon detection.

Proposed method

  • Conducted preliminary photon measurements using radioactive sources (e.g., 5.89 keV and 30.1 keV) on the monolithic ATLASPix sensor.
  • Measured energy resolution using both analog and digital outputs of individual pixels and the full detector.
  • Performed simulations to study the impact of pixel size, depth, and passive material on angular resolution and event efficiency.
  • Designed and fabricated AstroPix V1, a 18×18 pixel matrix with 200 µm pixels, using a 180 nm HV CMOS process for improved dynamic range and low power.
  • Implemented simplified readout with direct analog output routing and external time-over-threshold digitization for initial characterization.
  • Used simulation tools to model Compton event reconstruction and assess angular resolution and effective area under various conditions.

Experimental results

Research questions

  • RQ1Can monolithic silicon pixel sensors like ATLASPix achieve sufficient energy resolution for Compton telescopes in the MeV energy range?
  • RQ2How does the energy resolution of the analog versus digital output compare in the context of gamma-ray detection?
  • RQ3What are the optimal pixel size and sensor thickness for maximizing angular resolution and event efficiency in a Compton telescope?
  • RQ4How does the presence of passive material affect the performance of a pixel-based tracker in a Compton telescope?
  • RQ5To what extent can the ATLASPix sensor be adapted for high-energy photon detection in space-based astrophysics missions?

Key findings

  • The analog output of ATLASPix achieved an energy resolution of 7.69 ± 0.13% at 5.89 keV, demonstrating high precision at low energies.
  • At 30.1 keV, the energy resolution was 7.27 ± 1.18%, which exceeds the conservative 10% requirement at 60 keV and approaches the goal of <2% at 60 keV.
  • The digital output of the full detector yielded energy resolutions consistently above 100%, indicating a need for redesign to improve energy resolution.
  • Simulations showed that 500 µm pixel size and 500 µm silicon thickness are optimal, as they do not limit angular resolution and maintain high event efficiency.
  • The presence of passive material, especially above 5%, significantly reduces event selection efficiency, with a notable drop in efficiency below 0.1 mm pixel size due to energy threshold constraints.
  • AstroPix V1, a new 18×18 pixel matrix with 200 µm pixels and a deep P implant for crosstalk reduction, has been fabricated and is undergoing initial testing to enable future orbital missions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.