[Paper Review] Automatic Mass Detection in Breast Using Deep Convolutional Neural Network and SVM Classifier
This paper proposes a deep learning pipeline combining transfer learning with VGG19 and SVM classifiers for automatic breast mass detection in mammograms. It uses pre-trained VGG19 to extract high-level features from 454×454 patches, applies bagged decision trees for feature selection, and optimizes C-SVM and ν-SVM classifiers via grid search to maximize AUC. The method achieves a robust AUC of 0.994 ± 0.003 on the INbreast dataset, demonstrating high accuracy and generalization on CPU with minimal computational overhead.
Mammography is the most widely used gold standard for screening breast cancer, where, mass detection is considered as the prominent step. Detecting mass in the breast is, however, an arduous problem as they usually have large variations between them in terms of shape, size, boundary, and texture. In this literature, the process of mass detection is automated with the use of transfer learning techniques of Deep Convolutional Neural Networks (DCNN). Pre-trained VGG19 network is used to extract features which are then followed by bagged decision tree for features selection and then a Support Vector Machine (SVM) classifier is trained and used for classifying between the mass and non-mass. Area Under ROC Curve (AUC) is chosen as the performance metric, which is then maximized during classifier selection and hyper-parameter tuning. The robustness of the two selected type of classifiers, C-SVM, and \u{psion}-SVM, are investigated with extensive experiments before selecting the best performing classifier. All experiments in this paper were conducted using the INbreast dataset. The best AUC obtained from the experimental results is 0.994 +/- 0.003 i.e. [0.991, 0.997]. Our results conclude that by using pre-trained VGG19 network, high-level distinctive features can be extracted from Mammograms which when used with the proposed SVM classifier is able to robustly distinguish between the mass and non-mass present in breast.
Motivation & Objective
- To address the challenge of high variability in breast mass morphology, size, texture, and boundary in mammography.
- To develop a robust, computationally efficient method for distinguishing mass from non-mass regions using deep features and supervised classification.
- To optimize SVM hyperparameters (C and ν) via grid search to maximize AUC, ensuring high generalization performance.
- To validate the method's robustness across multiple cross-validation folds and data augmentations.
- To demonstrate that a small training set can yield high-performance classification when combined with transfer learning and feature selection.
Proposed method
- Transfer learning is applied using a pre-trained VGG19 network to extract deep convolutional features from 454×454 mammogram patches.
- Bagged decision trees are used to select the most discriminative features, reducing dimensionality and mitigating overfitting.
- Support Vector Machines (C-SVM and ν-SVM) are trained and optimized using extensive grid search to maximize Area Under the ROC Curve (AUC).
- Hyperparameters C and ν are tuned independently for each classifier type to achieve optimal performance.
- Five-fold cross-validation is used to evaluate robustness, with data augmentation (flipping and rotation) applied in later experiments.
- Performance is evaluated using AUC as the primary metric, with standard deviation reported across folds.
Experimental results
Research questions
- RQ1Can pre-trained VGG19 features effectively distinguish between mass and non-mass regions in mammograms?
- RQ2Does combining bagged decision tree feature selection with SVM improve classification robustness and AUC?
- RQ3Which SVM variant—C-SVM or ν-SVM—yields better performance when hyperparameters are optimally tuned?
- RQ4How does the method perform across different cross-validation folds and data augmentations?
- RQ5Can a high AUC be achieved with a small training set using transfer learning and careful hyperparameter optimization?
Key findings
- The proposed pipeline achieved a mean AUC of 0.994 ± 0.003 across all test folds, with the best performance in Experiment 3.
- Both C-SVM and ν-SVM achieved identical AUC values (0.994 ± 0.003) when optimized with C=100 and ν=0.005, indicating consistent performance.
- Experiment 3, which used 454×454 patches with geometric augmentation and feature selection, yielded the highest AUC and lowest standard deviation, indicating superior robustness.
- The method required only 3 hours and 18 minutes of computation time, demonstrating efficiency on CPU hardware.
- Experiment 4, which used a larger feature vector (25,088 features) and more data, showed a slightly lower AUC (0.988 ± 0.009) despite longer training time (12 hours), confirming the trade-off between complexity and performance.
- The ROC curves across all folds in Experiment 3 showed near-identical performance, confirming the method's consistency and robustness across different data splits.