[Paper Review] BIMCV COVID-19+: a large annotated dataset of RX and CT images from COVID-19 patients
A large open BIMCV-COVID-19+ dataset with chest X-ray, DX, and CT images from 1,311 COVID-19+ patients, annotated with radiological findings, ROI segmentations, and mapped to UMLS CUIs, plus an automated report-labeling pipeline.
This paper describes BIMCV COVID-19+, a large dataset from the Valencian Region Medical ImageBank (BIMCV) containing chest X-ray images CXR (CR, DX) and computed tomography (CT) imaging of COVID-19+ patients along with their radiological findings and locations, pathologies, radiological reports (in Spanish), DICOM metadata, Polymerase chain reaction (PCR), Immunoglobulin G (IgG) and Immunoglobulin M (IgM) diagnostic antibody tests. The findings have been mapped onto standard Unified Medical Language System (UMLS) terminology and cover a wide spectrum of thoracic entities, unlike the considerably more reduced number of entities annotated in previous datasets. Images are stored in high resolution and entities are localized with anatomical labels and stored in a Medical Imaging Data Structure (MIDS) format. In addition, 10 images were annotated by a team of radiologists to include semantic segmentation of radiological findings. This first iteration of the database includes 1,380 CX, 885 DX and 163 CT studies from 1,311 COVID-19+ patients. This is, to the best of our knowledge, the largest COVID-19+ dataset of images available in an open format. The dataset can be downloaded from http://bimcv.cipf.es/bimcv-projects/bimcv-covid19.
Motivation & Objective
- Provide a large open multi-institutional COVID-19 image dataset for AI research to aid diagnosis, prognosis, and triage.
- Map radiologic findings to Standard Unified Medical Language System (UMLS) CUIs to enable interoperable labeling across languages.
- Annotate radiologic findings and localizations, including ROI segmentations, to support supervised learning (including segmentation).
- Ensure robust data anonymization and ethical compliance while enabling open data sharing for the research community.
Proposed method
- Aggregate chest X-ray (CR/DX) and CT images from 11 hospitals in the Valencian Region.
- Anonymize patient data in reports and DICOM headers following DPO and HIPAA-like safeguards, using NER for report de-identification and DICOM confidentiality profiles.
- Automatically assign radiology labels to reports by retraining a PadChest-based multi-label LSTM with attention to include COVID-19 and COVID-19 uncertain terms, mapping labels to UMLS CUIs.
- Annotate ROI/ground-truth regions for 10 images by radiologists using XNAT OHIF Viewer to enable semantic segmentation (UNet-like) training.
- Convert raw pixel data to 16-bit PNG/nii.gz formats and estimate image projection/orientation with an EfficientNet-based network to standardize views.
- Structure data in Medical Imaging Data Structure (MIDS), integrating images (nii.gz), DICOM fields (JSON), and patient-derived data through TSV/JSON metadata files.
Experimental results
Research questions
- RQ1How effectively can radiological findings from Spanish radiology reports be mapped to UMLS CUIs for interoperable labeling across languages?
- RQ2What is the utility of ROI annotations and semantic labels for training lesion segmentation and detection models on COVID-19 imaging?
- RQ3What is the quality and reliability of automated COVID-19 related labels (COVID-19 vs COVID-19 uncertain) in large open datasets?
- RQ4How diverse and representative is the BIMCV-COVID-19+ data across modalities, devices, and time relative to diagnosis for AI research?
Key findings
- The first iteration includes 1,380 CX, 885 DX, and 163 CT studies from 1,311 patients, making it one of the largest open COVID-19 imaging datasets available at release.
- 10 images were annotated with pixel-level ROIs for key findings (ground-glass opacities, consolidations, etc.) to enable segmentation model training.
- Radiology labels were mapped to 336 CUIs under UMLS and a COVID-19 (CUI C5203670) and COVID-19 uncertain (CUI C5203671) vocabulary were added for focused COVID-19 labeling.
- An automated multi-label report classifier (Bidirectional LSTM with attention) achieved F1-micro of 0.922 on validation for the label set including COVID-19 terms, and 0.8281 accuracy on an independent test set.
- For COVID-19 related findings, the classifier achieved precision 0.961, recall 0.925, F1 0.943; for COVID-19 uncertain, precision 1.0, recall 0.846, F1 0.916.
- Overall label-set performance on the broader entity set yielded F1-weighted 0.9320, F1-micro 0.9378, and accuracy 0.8281.
Read this paper