[Paper Review] Breast Cancer Detection Using Convolutional Neural Networks
This study proposes a Faster R-CNN-based convolutional neural network (CNN) for automated detection and classification of breast masses in mammograms, integrating feature extraction, region proposal, and ROI pooling. The model achieves 91.86% detection accuracy, 94.67% sensitivity, and 92.2% AUC-ROC on a locally collected dataset from Ethiopian hospitals, significantly outperforming a VGG-based Faster R-CNN baseline.
Breast cancer is prevalent in Ethiopia that accounts 34% among women cancer patients. The diagnosis technique in Ethiopia is manual which was proven to be tedious, subjective, and challenging. Deep learning techniques are revolutionizing the field of medical image analysis and hence in this study, we proposed Convolutional Neural Networks (CNNs) for breast mass detection so as to minimize the overheads of manual analysis. CNN architecture is designed for the feature extraction stage and adapted both the Region Proposal Network (RPN) and Region of Interest (ROI) portion of the faster R-CNN for the automated breast mass abnormality detection. Our model detects mass region and classifies them into benign or malignant abnormality in mammogram(MG) images at once. For the proposed model, MG images were collected from different hospitals, locally.The images were passed through different preprocessing stages such as gaussian filter, median filter, bilateral filters and extracted the region of the breast from the background of the MG image. The performance of the model on test dataset is found to be: detection accuracy 91.86%, sensitivity of 94.67% and AUC-ROC of 92.2%.
Motivation & Objective
- To address the high misdiagnosis rate and long reporting delays in breast cancer diagnosis in Ethiopia, where manual interpretation leads to 10–30% error rates.
- To develop an automated deep learning system that detects and classifies breast masses as benign or malignant in digital mammograms.
- To provide a publicly available, locally collected dataset from Ethiopian hospitals to support future research in low-resource settings.
- To improve early detection accuracy and reduce reliance on subjective, time-consuming manual analysis in low-income countries.
Proposed method
- A custom CNN architecture was designed for feature extraction, replacing the standard VGG backbone in Faster R-CNN.
- The Region Proposal Network (RPN) and ROI pooling components of Faster R-CNN were adapted for end-to-end object detection of breast masses.
- Image preprocessing included Gaussian, median, and bilateral filtering, followed by breast region segmentation from the background.
- Data augmentation and batch normalization were applied to reduce overfitting and internal covariate shift.
- The model was trained and validated using a 1588-image dataset split into 80% training, 10% validation, and 10% testing, with radiologist-annotated bounding boxes.
- Hyperparameters of the base network, RPN, and ROI layers were tuned to improve detection and classification performance.
Experimental results
Research questions
- RQ1Can a Faster R-CNN-based CNN model achieve high accuracy in detecting and classifying breast masses in mammograms from low-resource Ethiopian healthcare settings?
- RQ2How does the performance of the proposed model compare to a VGG-based Faster R-CNN baseline in terms of detection accuracy, sensitivity, and AUC-ROC?
- RQ3To what extent do variations in imaging equipment, lighting, and acquisition settings across hospitals affect model generalization and classification reliability?
- RQ4How effective is the model in localizing small breast mass abnormalities with low Intersection over Union (IoU) thresholds?
- RQ5Can the integration of batch normalization and dropout layers reduce overfitting and improve model robustness on a limited, heterogeneous dataset?
Key findings
- The proposed model achieved a detection accuracy of 91.86% on the test dataset, significantly outperforming the VGG-based Faster R-CNN baseline (84.88%).
- The model demonstrated a sensitivity (recall) of 94.67%, indicating strong ability to correctly identify malignant masses.
- The Area Under the ROC Curve (AUC-ROC) reached 92.2%, showing superior classification performance compared to the VGG-based model (84.3%).
- The model achieved an Intersection over Union (IoU) of 94.2% at a threshold of 0.25, indicating high localization accuracy for small mass abnormalities.
- Only 14 out of 1588 test cases were misclassified by the proposed model, compared to 26 by the VGG-based baseline, highlighting improved robustness.
- The use of batch normalization and dropout layers effectively mitigated overfitting and internal covariate shift, contributing to improved generalization on heterogeneous data.