[Paper Review] Calibration of multi-physics computational models using Bayesian networks
This paper proposes a Bayesian network-based framework for calibrating multi-physics computational models under mixed aleatoric and epistemic uncertainty, integrating diverse data types (interval and time-series data) and enabling efficient parameter identifiability assessment via first-order Taylor expansion. The method improves calibration efficiency and accuracy by sharing common parameters across models and modeling discrepancy as a Gaussian process or random variable depending on data availability, demonstrated on MEMS device models with significant uncertainty quantification gains.
This paper develops a Bayesian network-based method for the calibration of multi-physics models, integrating various sources of uncertainty with information from computational models and experimental data. We adopt the Kennedy and O'Hagan (KOH) framework for model calibration under uncertainty, and develop extensions to multi-physics models and various scenarios of available data. Both aleatoric uncertainty (due to natural variability) and epistemic uncertainty (due to lack of information, including data uncertainty and model uncertainty) are accounted for in the calibration process. Challenging aspects of Bayesian calibration for multi-physics models are investigated, including: (1) calibration with different forms of experimental data (e.g., interval data and time series data), (2) determination of the identifiability of model parameters when the analytical expression of model is known or unknown, (3) calibration of multiple physics models sharing common parameters, which enables efficient use of data especially when the experimental resources are limited. A first-order Taylor series expansion-based method is proposed to determine which model parameters are identifiable. Following the KOH framework, a probabilistic discrepancy function is estimated and added to the prediction of the calibrated model, attempting to account for model uncertainty. This discrepancy function is modeled as a Gaussian process when sufficient data are available for multiple model input combinations, and is modeled as a random variable when the available data are limited. The overall approach is illustrated using two application examples related to microelectromechanical system (MEMS) devices: (1) calibration of a dielectric charging model with time-series data, and (2) calibration of two physics models (pull-in voltage and creep) using measurements of different physical quantities in different devices.
Motivation & Objective
- To address challenges in calibrating multi-physics models under mixed uncertainty sources, including limited and heterogeneous experimental data.
- To develop a systematic approach for identifying which model parameters are estimable (identifiable) given available data and model structure.
- To enable efficient use of sparse experimental data by sharing information across multiple physics models through a Bayesian network.
- To extend the Kennedy and O’Hagan framework to multi-physics systems with shared parameters and diverse data types.
- To reduce computational cost in likelihood evaluation and posterior inference for complex, multi-model systems.
Proposed method
- Uses a Bayesian network to represent probabilistic dependencies among model inputs, outputs, parameters, and observed data, enabling structured inference.
- Applies the Kennedy and O’Hagan (KOH) framework with a probabilistic discrepancy function to account for model uncertainty.
- Models the discrepancy as a Gaussian process when sufficient data exist for multiple input combinations, otherwise as a random variable.
- Employs a first-order Taylor series expansion to assess parameter identifiability, especially useful when the model has no explicit analytical form.
- Calibrates shared parameters across multiple physics models (e.g., pull-in voltage and creep models) by propagating posterior distributions as priors in sequential steps.
- Uses trapezoidal integration for posterior computation in low-dimensional parameter spaces, ensuring convergence with uniform grid refinement.
Experimental results
Research questions
- RQ1How can Bayesian calibration be effectively applied to multi-physics models with heterogeneous data types such as interval data and time-series data?
- RQ2Which model parameters are identifiable given limited data and complex model structure, and how can identifiability be assessed efficiently?
- RQ3How can information from multiple experimental measurements on different physical quantities be efficiently combined in a multi-model calibration framework?
- RQ4What is the impact of data scarcity on the estimation of discrepancy functions, and how should they be modeled under such conditions?
- RQ5How can shared parameters across multiple physics models be calibrated consistently while minimizing computational cost?
Key findings
- The first-order Taylor series expansion method successfully identifies non-identifiable parameters, reducing unnecessary computational effort in calibration.
- For the dielectric charging model, the posterior mean of the charge parameter was estimated at 1.35e-7 C with a standard deviation of 1.44e-7 C, showing good agreement with time-series data.
- In the two-device MEMS example, the posterior mean of Young’s modulus E was estimated at 194.7 GPa (posterior standard deviation 5.51 GPa), with minimal change from the prior, indicating data insufficiency for E.
- The calibration results were consistent across different data combination strategies, confirming that posterior distributions of shared parameters (e.g., E) converge to the same distribution when all data are used.
- The discrepancy function was modeled as a Gaussian process when data were sufficient and as a random variable when data were sparse, with both approaches improving model prediction accuracy.
- The Bayesian network framework enabled efficient information sharing across models, reducing overall uncertainty and improving calibration efficiency in multi-physics settings.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.