TL;DR

This study pioneers the use of coded aperture and Compton imaging to directly visualize and quantify the 225Ac daughter isotopes 221Fr (218 keV) and 213Bi (440 keV) in tumor-bearing mice, overcoming the limitations of traditional biodistribution studies. It demonstrates the first in vivo imaging of 225Ac daughter redistribution using these advanced gamma-ray imaging techniques, enabling non-invasive, longitudinal monitoring of radiopharmaceutical behavior with quantitative validation against ex vivo measurements.

ABSTRACT

Targeted alpha-particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is $^{225}$Ac. The development of $^{225}$Ac-based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage. The ability to directly image the daughters, namely $^{221}$Fr and $^{213}$Bi, via their gamma-ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on pinhole collimation, cannot be employed due to sensitivity limitations. As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218-keV gamma-ray emission of $^{221}$Fr and the latter suited to the 440-keV gamma-ray emission of $^{213}$Bi. This work includes coded aperture images of $^{221}$Fr and Compton images of $^{213}$Bi in tumor-bearing mice injected with $^{225}$Ac-based radiopharmaceuticals. These results are the first demonstration of visualizing and quantifying the $^{225}$Ac daughters in small animals via coded aperture and Compton imaging and serve as a stepping stone for future radiopharmaceutical studies.

Motivation & Objective

  • To address the lack of effective methods for preclinical imaging of 225Ac daughter nuclides (221Fr and 213Bi) in small animals.
  • To overcome the sensitivity and resolution limitations of conventional SPECT and PET in imaging high-energy gamma emissions from 225Ac daughters.
  • To develop and validate a dual-modality imaging system using coded aperture and Compton imaging for non-invasive, longitudinal monitoring of radiopharmaceutical biodistribution.
  • To provide quantitative validation of in vivo imaging results through comparison with ex vivo biodistribution analyses.
  • To enable improved understanding of daughter redistribution dynamics to support the clinical translation of 225Ac-based targeted alpha therapy.

Proposed method

  • Coded aperture imaging was applied to detect 218-keV gamma rays from 221Fr using a mask with a 1.5 mm strip pitch and a 1.5× magnification factor.
  • Compton imaging was used to detect 440-keV gamma rays from 213Bi, employing a position-sensitive detector with a 4.1 mm spatial resolution at 35 mm source-to-detector distance.
  • The dual-modality imager was tested on a 225Ac-filled phantom and in tumor-bearing mice injected with 225Ac-based radiopharmaceuticals.
  • Image reconstruction was performed using deconvolution techniques to resolve source distributions from coded aperture patterns and Compton kinematics.
  • Activity quantification was extracted from reconstructed images and validated against ex vivo biodistribution data from organ counting.
  • Sensitivity and resolution were optimized through detector geometry, mask design, and signal processing improvements, including reduced strip pitch and shorter standoff distances.

Experimental results

Research questions

  • RQ1Can coded aperture imaging effectively detect and localize 218-keV gamma emissions from 221Fr in small-animal models?
  • RQ2Can Compton imaging achieve sufficient spatial resolution and sensitivity to image 440-keV gamma emissions from 213Bi in vivo?
  • RQ3How do the in vivo activity estimates from coded aperture and Compton imaging compare to ex vivo biodistribution measurements?
  • RQ4To what extent can these imaging modalities resolve organ-specific uptake and redistribution of 225Ac daughters over time?
  • RQ5Can the imaging system detect and quantify differences in biodistribution patterns between individual animals, such as in the liver, heart, and lungs?

Key findings

  • Coded aperture imaging successfully visualized 221Fr in tumor-bearing mice with a total activity estimate of approximately 299 Bq, closely matching the ex vivo biodistribution result of 217 Bq.
  • Compton imaging detected 213Bi with a total activity estimate of about 242 Bq, in good agreement with the ex vivo measurement of 198 Bq.
  • In a mouse with significant organ uptake, the coded aperture and Compton images estimated 610 Bq and 575 Bq of 221Fr and 213Bi, respectively, compared to 437 Bq and 434 Bq from ex vivo analysis.
  • The imaging system achieved a coded aperture resolution of 6.9 mm and a Compton resolution of 4.1 mm at current detector and geometry settings.
  • Improvements in resolution are feasible through reduced strip pitch (e.g., 0.5 mm) and increased magnification (e.g., 3×), which could improve coded aperture resolution by up to 75% and 50%, respectively.
  • Sensitivity could be enhanced by a factor of 16 through reduced standoff distance and adding detector panels, with further gains possible via optimized signal processing and finer detector granularity.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.