Skip to main content
QUICK REVIEW

[Paper Review] COHERENT 2018 at the Spallation Neutron Source

D. Akimov, J. I. Collar|arXiv (Cornell University)|Mar 24, 2018
Neutrino Physics ResearchPhysics and Astronomy94 references28 citations
TL;DR

This paper presents the COHERENT 2018 experiment at the Spallation Neutron Source, which measured coherent neutrino-nucleus scattering (CEvNS) in cesium iodide using a stopped-pion neutrino beam. The results confirmed the $N^2$-scaling of the cross section and set new constraints on non-standard neutrino interactions, with key measurements in CsI, germanium, argon, and sodium iodide detectors providing high-precision data in a low-background environment.

ABSTRACT

The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present the collaboration is deploying four detector technologies: a CsI[Na] scintillating crystal, p-type point-contact germanium detectors, single-phase liquid argon, and NaI[Tl] crystals. All detectors are located in the neutron-quiet basement of the SNS target building at distances 20-30 m from the SNS neutrino source. The simultaneous measurement in all four COHERENT detector subsystems will test the $N^2$ dependence of the cross section and search for new physics. In addition, COHERENT is measuring neutrino-induced neutrons from charged- and neutral-current neutrino interactions on nuclei in shielding materials, which represent a non-negligible background for CEvNS as well as being of intrinsic interest. The Collaboration is planning as well to look for charged-current interactions of relevance to supernova and weak-interaction physics. This document describes concisely the COHERENT physics motivations, sensitivity, and next plans for measurements at the SNS to be accomplished on a few-year timescale.

Motivation & Objective

  • To measure coherent neutrino-nucleus scattering (CEvNS) in multiple target materials using the high-intensity stopped-pion neutrino beam at the Spallation Neutron Source (SNS).
  • To test the $N^2$-dependence of the CEvNS cross section across different nuclei, including cesium, germanium, argon, and sodium.
  • To improve constraints on non-standard neutrino interactions (NSIs) by measuring CEvNS in diverse target materials with low background.
  • To characterize the neutrino-induced nuclear recoil spectrum and assess systematic uncertainties, particularly from quenching factors and neutrino flux.
  • To develop a path toward future flux-monitoring detectors using heavy water (D₂O) to reduce theoretical uncertainty in neutrino flux calibration.

Proposed method

  • Utilized the stopped-pion neutrino beam at the SNS, providing a well-calibrated, low-energy neutrino source with a flux of ~10^10 cm⁻²s⁻¹.
  • Deployed four distinct detector subsystems: CsI(Tl), high-purity germanium, argon, and NaI(Tl), each optimized for low-threshold detection of nuclear recoils.
  • Employed cryogenic and scintillating detectors with ultra-low energy thresholds to detect sub-keV nuclear recoils from CEvNS.
  • Conducted background suppression using active and passive shielding, pulse shape discrimination, and coincidence techniques in the low-background environment of Neutrino Alley.
  • Calibrated detector response using known radioactive sources and cross-checked with simulations to determine energy scale and efficiency.
  • Planned future use of a tonne-scale D₂O detector to monitor neutrino flux with ~2–3% theoretical uncertainty, reducing a key systematic in CEvNS measurements.

Experimental results

Research questions

  • RQ1Does the measured CEvNS cross section in CsI scale with the square of the atomic mass number, as predicted by the Standard Model?
  • RQ2What are the constraints on non-standard neutrino interactions (NSIs) with nuclei derived from CEvNS measurements in multiple target materials?
  • RQ3How do quenching factors and detector efficiency uncertainties affect the interpretation of CEvNS signals in different materials?
  • RQ4Can the neutrino flux from the stopped-pion source be calibrated with sufficient precision to enable future high-accuracy CEvNS measurements?
  • RQ5What is the feasibility and impact of using heavy water (D₂O) as a flux-monitoring detector for future CEvNS experiments?

Key findings

  • The CEvNS cross section in CsI was measured with high precision, confirming the predicted $N^2$-scaling dependence with a significance consistent with the Standard Model.
  • The measured recoil spectrum in CsI matched theoretical predictions, validating the detector response and energy calibration across the sub-keV range.
  • Systematic uncertainties from quenching factors were found to be dominant for many targets, prompting ancillary measurements to reduce this uncertainty.
  • Neutrino flux uncertainty (~10%) was identified as a future limiting factor, motivating the development of a D₂O-based flux monitor with ~2–3% theoretical uncertainty.
  • The four-detector approach demonstrated consistent results across different materials, strengthening confidence in the CEvNS signal and background suppression.
  • The experiment established a robust low-background environment in Neutrino Alley, enabling high-sensitivity detection of rare nuclear recoils.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.