Skip to main content
QUICK REVIEW

[Paper Review] The CLEAR Experiment

K. Scholberg, T. Wongjirad|ArXiv.org|Oct 12, 2009
Atomic and Molecular PhysicsPhysics and Astronomy2 references10 citations
TL;DR

The CLEAR experiment proposes to measure coherent elastic neutrino-nucleus scattering (CE$ν$NS) at the Spallation Neutron Source (SNS) using a 456 kg liquid argon or 391 kg liquid neon scintillation detector placed 46 m from the SNS target. By exploiting the SNS's pulsed, high-intensity neutrino beam—primarily 29.9 MeV $ν_\mu$ from stopped $π^+$ decay—the experiment aims to achieve a 12–13% uncertainty in measuring the CE$ν$NS rate, providing a precision test of the Standard Model and probing new physics via low-threshold nuclear recoils.

ABSTRACT

The Spallation Neutron Source in Oak Ridge, Tennessee, is designed to produce intense pulsed neutrons for various science and engineering applications. Copious neutrinos are a free by-product. When it reaches full power, the SNS will be the world's brightest source of neutrinos in the few tens of MeV range. The proposed CLEAR (Coherent Low Energy A (Nuclear) Recoils) experiment will measure coherent elastic neutral current neutrino-nucleus scattering at the SNS. The physics reach includes tests of the Standard Model.

Motivation & Objective

  • To perform the first direct measurement of coherent elastic neutrino-nucleus scattering (CE$ν$NS) at a pulsed accelerator-based neutrino source.
  • To test the Standard Model prediction of CE$ν$NS cross-sections in the few tens of MeV energy range.
  • To probe new physics beyond the Standard Model through precision measurement of low-energy nuclear recoils.
  • To demonstrate background suppression techniques in noble liquid detectors using beam timing and active background characterization.
  • To achieve a sub-15% uncertainty in the CE$ν$NS rate measurement, with flux uncertainty as the dominant systematic.

Proposed method

  • Utilize the SNS's pulsed 60 Hz proton beam to produce a well-defined, monochromatic 29.9 MeV $ν_\mu$ flux via stopped $π^+$ decay.
  • Deploy a single-phase liquid argon or liquid neon scintillation detector at 46 m from the SNS target to detect low-energy nuclear recoils from CE$ν$NS.
  • Apply a beam timing cut to reject beam-related neutron backgrounds, leveraging the 60 Hz pulse structure for a background rejection factor of ~$10^{-4}$.
  • Characterize non-beam backgrounds (cosmic rays, radioactivity, 39Ar, radon daughters) using off-beam data and simulations.
  • Use gamma-ray calibration sources and known scintillation efficiencies to determine the energy scale and threshold with ~4% uncertainty.
  • Apply a flat pulse shape discrimination cut (later replaced by energy-dependent cut) to suppress non-recoil signals while preserving signal efficiency.

Experimental results

Research questions

  • RQ1Can coherent elastic neutrino-nucleus scattering be observed at a pulsed accelerator neutrino source with a low-threshold noble liquid detector?
  • RQ2What is the precision with which the CE$ν$NS rate can be measured at the SNS, given the dominant systematic uncertainties?
  • RQ3How effectively can beam-related and non-beam-related backgrounds be suppressed and quantified in a noble liquid detector?
  • RQ4To what extent does the measured CE$ν$NS rate agree with the Standard Model prediction at ~30 MeV neutrino energy?
  • RQ5Can the detector achieve sufficient background rejection and energy threshold stability to resolve sub-MeV nuclear recoils?

Key findings

  • The CLEAR experiment expects to measure the CE$ν$NS rate with a total uncertainty of 12% for liquid argon and 13% for liquid neon over one year of data.
  • The dominant uncertainty in the rate measurement is the neutrino flux uncertainty, estimated at 10%.
  • The energy threshold uncertainty contributes ~4% (argon) and ~3% (neon) to the total systematic uncertainty.
  • Beam-related neutron backgrounds are estimated to be comfortably small after timing cuts, with no significant impact on signal detection.
  • Radon daughter backgrounds are expected to be below 100 m⁻² day⁻¹ in the energy region of interest, consistent with demonstrated performance in similar experiments like DEAP-I.
  • The signal exhibits a characteristic time structure (prompt from $ν_\mu$ and delayed from $μ^+$ decay), enabling effective discrimination from background.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.