[Paper Review] Compact Michelson interferometers with subpicometer sensitivity
This paper presents a compact, commercially built Michelson interferometer using deep frequency modulation and laser frequency stabilization to achieve subpicometer displacement sensitivity of 0.3 pm/√Hz above 0.1 Hz. The system linearizes the interferometric response over multiple fringes via fringe-counting and uses one sensing head as a frequency reference to suppress laser noise, enabling high-precision displacement sensing suitable for gravitational-wave detectors and other precision experiments.
The network of interferometric gravitational-wave observatories has successfully detected tens of astrophysical signals since 2015. In this paper, we experimentally investigate compact sensors that have the potential to improve the sensitivity of gravitational-wave detectors to intermediate-mass black holes. We use only commercial components, such as sensing heads and lasers, to assemble the setup and demonstrate its subpicometer precision. The setup consists of a pair of Michelson interferferometers that use deep frequency modulation techniques to obtain a linear, relative displacement readout over multiple interference fringes. We implement a laser-frequency stabilisation scheme to achieve a sensitivity of 0.3\,$ ext{pm} / \sqrt{ ext{Hz}}$ above 0.1\,Hz. The device has also the potential to improve other experiments, such as torsion balances and commercial seismometers.
Motivation & Objective
- Address the fundamental limitation of current displacement sensors in gravitational-wave detectors, which are constrained by readout noise and control floor below 30 Hz.
- Develop a compact, low-cost displacement sensor using only commercial components to improve sensitivity for detecting intermediate-mass black holes and other low-frequency astrophysical signals.
- Overcome nonlinearity and laser frequency noise in interferometric displacement readout through frequency modulation and reference-based stabilization.
- Enable practical deployment in existing infrastructure by shifting complexity to the digital domain while maintaining high precision.
- Demonstrate applicability to next-generation sensors such as 6D seismometers and advanced suspension systems in LIGO.
Proposed method
- Implement a dual-Michelson interferometer setup using commercial sensing heads and lasers to enable relative displacement measurement.
- Apply deep frequency modulation to the laser to linearize the interferometric response over multiple interference fringes, enabling extended dynamic range.
- Use a fringe-counting algorithm to resolve absolute displacement across multiple fringes, avoiding ambiguity in phase measurement.
- Stabilize the laser frequency by using one sensing head as a reference to suppress laser frequency noise, a key source of sensitivity degradation.
- Extract phase from the Lissajous figure formed by the modulated interferometer signals using a simplified real-time algorithm based on elliptical fitting.
- Characterize nonlinearity in phase extraction using circular and static elliptical fits, and assess its impact under high-RMS displacement conditions.
Experimental results
Research questions
- RQ1Can a compact, commercially assembled Michelson interferometer achieve subpicometer sensitivity using only off-the-shelf components?
- RQ2How effective is deep frequency modulation in linearizing the interferometric response over multiple fringes without complex feedback loops?
- RQ3To what extent can laser frequency noise be suppressed using a single sensing head as a frequency reference?
- RQ4What are the dominant sources of nonlinearity in phase extraction, and how do they scale with displacement amplitude?
- RQ5Can this system be practically deployed in existing gravitational-wave detectors to improve control sensitivity below 30 Hz?
Key findings
- The interferometer achieves a displacement sensitivity of 0.3 pm/√Hz above 0.1 Hz, significantly improving upon existing shadow sensors.
- Deep frequency modulation enables a linear, relative displacement readout over multiple interference fringes, extending the dynamic range of the sensor.
- Laser frequency noise is effectively suppressed by using one sensing head as a reference, reducing its contribution to the overall noise budget.
- Nonlinearities in phase extraction are quantified at 0.12% RMS when using a static elliptical fit, with potential for improvement via dynamic parameter correction.
- The system is suitable for low-RMS applications such as Advanced LIGO quadruple suspensions, where displacement amplitudes are small enough to maintain linearity with the current phase extraction method.
- The sensor’s compact design and reliance on digital signal processing make it a low-impact upgrade for existing gravitational-wave detectors and other precision instruments.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.