Skip to main content
QUICK REVIEW

[Paper Review] ConvRML: High-Quality Lensless Imaging with Random Multi-Focal Lenslets

Leyla Kabuli, Clara S. Hung|arXiv (Cornell University)|Feb 4, 2026
Random lasers and scattering mediaPhysics and Astronomy0 citations
TL;DR

ConvRML combines a precision-fabricated random multi-focal lenslet (RML) phase mask with a ConvNeXt reconstruction network, supported by 100,000-measurement open datasets, to achieve higher-quality lensless imaging than diffuser-based systems. It reports up to 6.68 dB PSNR gains and demonstrates strong generalization to real-world objects.

ABSTRACT

Mask-based lensless imagers use simple optics and computational reconstruction to design compact form factor cameras with compressive imaging ability. However, these imagers generally suffer from poor reconstruction quality. Here, we describe several advances in both hardware and software that result in improved lensless imaging quality. First, we use a precision-manufactured random multi-focal lenslet (RML) phase mask to produce improved measurements with reduced multiplexing. Next, we implement a ConvNeXt-based reconstruction architecture, which provides up to 6.68 dB improvement in peak signal-to-noise ratio over state-of-the-art attention-based architectures. Finally, we establish a parallel imaging setup that simultaneously images a scene with RML, diffuser and lens systems, with which we collect datasets with 100,000 measurements for each system, to be used for reconstruction model training and evaluation. Using this standardized system, we quantify the improved measurement quality of the RML compared to a diffuser using the modulation transfer function and mutual information. Our ConvRML system benefits from both the optical and the computational developments presented in this work, and our contributions establish resources to support continued development of high-quality, compact, and compressive lensless imagers.

Motivation & Objective

  • Advance lensless imaging quality by improving optical encoding through a precision random multi-focal lenslet (RML) phase mask.
  • Develop and evaluate a modern deep learning reconstruction architecture (ConvNeXt) capable of exploiting higher-quality measurements.
  • Provide standardized, open datasets to enable controlled comparisons across optical encoders and reconstruction algorithms.

Proposed method

  • Design and fabricate a random multi-focal lenslet (RML) phase mask with pseudo-random lenslet positions to reduce PSF correlations and limit multiplexing.
  • Capture and compare measurements from RML, diffuser, and traditional lens under identical conditions using a parallel hardware setup.
  • Train ConvNeXt-based reconstruction models (ConvRML) on 50k–100k measurements to evaluate performance versus attention-based architectures.
  • Create and release parallel Open Source datasets with 100,000 measurements for each system to enable standardized benchmarking.
  • Quantify optical encoder quality via Modulation Transfer Function (MTF) and Mutual Information (MI) under varying noise and bit-depth conditions.
Figure 1: ConvRML system overview. (top) Our high-quality lensless imaging system combines a random multi-focal lenslet (RML) phase mask with a ConvNeXt reconstruction architecture. (middle) To facilitate data-driven training of reconstruction architectures and controlled system comparisons between
Figure 1: ConvRML system overview. (top) Our high-quality lensless imaging system combines a random multi-focal lenslet (RML) phase mask with a ConvNeXt reconstruction architecture. (middle) To facilitate data-driven training of reconstruction architectures and controlled system comparisons between

Experimental results

Research questions

  • RQ1Does the RML optical encoder provide higher-quality measurements than a diffuser and conventional lens under identical conditions?
  • RQ2Can a ConvNeXt-based reconstruction outperform attention-based architectures for lensless imaging with different encoders?
  • RQ3How does dataset size affect the relative performance of reconstruction architectures on high- versus low-multiplexing encoders?
  • RQ4Do models trained on display-based data generalize to real-world objects under varying illumination and alignment?

Key findings

  • RML improves measurement quality over a diffuser, with higher frequency transfer in MTF analyses and better MI under noise and quantization.
  • ConvNeXt-based reconstruction achieves up to 6.68 dB PSNR improvement over state-of-the-art attention-based architectures on the RML and diffuser encoders.
  • On the Diffuser dataset, ConvNeXt attains the highest reported PSNR/SSIM of 25.37 dB and 0.762 SSIM, outperforming ViT, Swin, and Lensless Imaging Transformer in that setting.
  • On the Parallel Lensless Dataset, ConvNeXt reconstruction on RML achieves 27.19 dB PSNR and 0.830 SSIM, surpassing all compared models.
  • Dataset size optimization shows ConvNeXt benefits up to 50,000–50k measurements with diminishing returns beyond that, indicating good matching of model capacity to data.
  • Reconstructions generalize well to real-world objects, with RML recovering fine textures and edges more accurately than the diffuser under varied materials and illumination.
Figure 2: Random multi-focal lenslet (RML) phase masks result in good measurement quality. a) Illustration and b) experimentally-measured point spread functions (PSFs) for different optical encoders with a fixed numerical aperture $\theta$ . A lens focuses light to a single focal point, with the fie
Figure 2: Random multi-focal lenslet (RML) phase masks result in good measurement quality. a) Illustration and b) experimentally-measured point spread functions (PSFs) for different optical encoders with a fixed numerical aperture $\theta$ . A lens focuses light to a single focal point, with the fie

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.