[Paper Review] COOLL: Controlled On/Off Loads Library, a Public Dataset of High-Sampled Electrical Signals for Appliance Identification
This paper introduces COOLL, a public high-sampled electrical signal dataset of 42 controllable appliances measured at 100 kHz, capturing 20 controlled turn-on transients per appliance with precise timing relative to the mains voltage zero-crossing. The dataset enables high-frequency NILM research by providing detailed turn-on transient variations, filling a gap in existing datasets for appliance identification and energy disaggregation.
This paper gives a brief description of the Controlled On/Off Loads Library (COOLL) dataset. This latter is a dataset of high-sampled electrical current and voltage measurements representing individual appliances consumption. The measurements were taken in June 2016 in the PRISME laboratory of the University of Orléans, France. The appliances are mainly controllable appliances (i.e. we can precisely control their turn-on/off time instants). 42 appliances of 12 types were measured at a 100 kHz sampling frequency.
Motivation & Objective
- Address the lack of high-sampled, individual-appliance datasets with precise turn-on timing control for non-intrusive load monitoring (NILM) research.
- Provide a dataset that captures the variation of turn-on transient waveforms based on the timing of appliance activation relative to the mains voltage cycle.
- Support the development and training of supervised NILM algorithms by offering labeled, high-resolution electrical signals for individual appliances.
- Enable detailed analysis of transient current behavior in controllable appliances, particularly the dependency of waveforms on turn-on instants.
- Facilitate future research on simultaneous appliance scenarios and non-controllable appliances through a scalable, extensible dataset framework.
Proposed method
- Measure individual appliances at a 100 kHz sampling frequency using a custom measurement system with precise timing control.
- Control the turn-on action delay relative to the mains voltage zero-crossing (from 0 to 19 ms in 1 ms steps), ensuring 20 distinct turn-on transients per appliance.
- Use a pre-trigger duration of 0.5–1 second and a post-stop duration of 1 second to capture stable off-state and on-state behavior.
- Record both current and voltage signals simultaneously for each appliance, with each measurement lasting 6 seconds.
- Store metadata in .xlsx header files (e.g., appliance type, nominal power, brand, grid parameters) and configuration files in .txt format for each measurement instance.
- Fix the turn-off action delay at 0 ms for consistency across all measurements, while varying only the turn-on delay.
Experimental results
Research questions
- RQ1How does the waveform of the turn-on transient current vary with respect to the timing of appliance activation relative to the mains voltage zero-crossing?
- RQ2To what extent can high-sampled electrical signals (100 kHz) improve the accuracy of appliance identification in non-intrusive load monitoring (NILM) systems?
- RQ3Can controlled turn-on transients be reliably reproduced and used as unique signatures for appliance classification?
- RQ4How do different appliance types (e.g., drills, vacuum cleaners, hair dryers) exhibit distinct transient current behaviors under controlled turn-on conditions?
- RQ5What is the feasibility of using such a dataset to train and validate high-frequency NILM algorithms with precise labeling?
Key findings
- COOLL provides 840 individual current and voltage signals from 42 appliances across 12 types, each with 20 controlled turn-on transients.
- The dataset captures the full 20 ms cycle of the 50 Hz mains voltage, enabling analysis of transient behavior across all possible turn-on instants.
- The 100 kHz sampling rate ensures high temporal resolution, essential for resolving fast transients in appliance inrush currents.
- The dataset includes detailed metadata such as nominal power, brand, grid voltage (230 V), and frequency (50 Hz), enhancing reproducibility and context.
- Each measurement includes a pre-trigger (0.5–1 s) and post-stop (1 s) phase, ensuring stable baseline and decay observations.
- The dataset is publicly available and designed for extensibility, supporting future expansions to include non-controllable appliances and simultaneous appliance scenarios.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.