Skip to main content
QUICK REVIEW

[Paper Review] Circular polarization control for the LCLS baseline in the soft X-ray regime

Gianluca Geloni, Vitali Kocharyan|arXiv (Cornell University)|Dec 23, 2010
Advanced X-ray Imaging TechniquesPhysics and Astronomy3 references5 citations
TL;DR

This paper proposes a low-cost, easily implementable method to generate 10 GW-level, 99% circularly polarized X-rays at the fundamental harmonic in the soft X-ray regime using the LCLS baseline. By inserting a 5 m long APPLE II helical undulator after a 40 m straight section downstream the planar undulator, the pre-existing microbunching is preserved, enabling coherent radiation emission with high polarization purity and minimal impact on baseline operation.

ABSTRACT

The LCLS baseline includes a planar undulator system, producing linearly polarized light in the range 0.15-1.5 nm. Polarization control in the soft X-ray region from linear to circular is highly desirable. Several schemes using helical undulators have been discussed for the LCLS. One consists in replacing three of the last planar undulator segments by APPLE III. A second proposal, the 2nd harmonic helical afterburner, uses short, crossed undulators tuned to the second harmonic. This last scheme is expected to be the better one. Its advantages are a high and stable degree of circular polarization and a low cost. Its disadvantage is a small output power and a narrow wavelength range. We propose a novel method to generate 10 GW level power at the fundamental harmonic with 99% degree of circular polarization from the LCLS baseline. Its merits are low cost, simplicity and easy implementation. After the baseline undulator, the electron beam is sent through a 40 m long straight section, and subsequently passes through a short APPLE II radiator. The microbunch structure is easily preserved, and intense coherent radiation is emitted in the helical radiator. The background radiation from the baseline undulator is suppressed by letting radiation and electrons through horizontal and vertical slits upstream the helical radiator, where the radiation spot size is about ten times larger than the electron bunch transverse size. Using thin Beryllium foils for the slits the divergence of the electron beam halo increases by Coulomb scattering, but the beam will propagate through the setup without electron losses. The applicability of our method is not restricted to the LCLS baseline setup. LCLS II or the European XFEL may benefit from this work as well, due to availability of sufficiently long free space at the end of undulator tunnel.

Motivation & Objective

  • To enable high-fidelity circular polarization control in the soft X-ray regime at the LCLS baseline, crucial for studying ultrafast magnetic phenomena and material properties.
  • To address the limitation of the LCLS baseline planar undulator, which produces only linearly polarized radiation, by introducing a practical polarization control scheme.
  • To achieve >99% degree of circular polarization at 10 GW peak power without compromising the baseline operation or requiring major redesign.
  • To develop a cost-effective, low-risk solution compatible with existing LCLS infrastructure and readily implementable at other XFEL facilities.

Proposed method

  • A 40 m long straight section is inserted after the baseline planar undulator to preserve electron beam microbunching before the helical radiator.
  • A 5 m long APPLE II-type helical undulator is installed downstream, tuned to the fundamental harmonic (1.5 nm), to generate coherent circularly polarized radiation from the pre-bunched beam.
  • Horizontal and vertical slits are placed upstream the helical undulator to suppress background radiation from the baseline undulator, using the larger radiation spot size compared to electron bunch size.
  • Thin beryllium foils are used as slits to increase electron beam halo divergence via Coulomb scattering, minimizing electron loss while filtering unwanted radiation.
  • The method relies on the SASE process in the planar undulator to create microbunching, which is then exploited coherently in the helical radiator to produce intense, circularly polarized pulses.
  • The scheme is designed to be non-intrusive: it does not alter the baseline undulator operation and can be rapidly installed with minimal downtime.

Experimental results

Research questions

  • RQ1Can a high degree of circular polarization (>99%) be achieved at the fundamental harmonic in the soft X-ray regime using a compact, downstream helical undulator?
  • RQ2Can the microbunching from the baseline planar undulator be preserved over a 40 m straight section to enable coherent radiation in a subsequent helical radiator?
  • RQ3Can background radiation from the baseline undulator be effectively suppressed without significant electron beam loss?
  • RQ4What is the achievable peak power and spectral bandwidth of circularly polarized radiation using this configuration?
  • RQ5Is the proposed method cost-effective, safe, and compatible with existing XFEL infrastructure such as LCLS or European XFEL?

Key findings

  • The proposed scheme achieves a peak power of approximately 10 GW at the fundamental harmonic (1.5 nm), matching the saturation power of the baseline LCLS undulator.
  • The degree of circular polarization reaches 99%, significantly exceeding the 90% limit of previous harmonic-based schemes and approaching the theoretical maximum.
  • The method preserves the baseline operation of the LCLS undulator, as the helical radiator is installed downstream and does not interfere with the original electron beam path or tuning.
  • Background radiation is effectively suppressed by placing slits upstream the helical undulator, where the radiation spot size is about ten times larger than the electron bunch transverse size.
  • Electron beam losses are minimized despite Coulomb scattering from thin beryllium foil slits, as the beam halo divergence increases without significant loss of core beam.
  • The scheme is scalable and applicable to other XFEL facilities such as LCLS II and the European XFEL, provided a sufficiently long free space exists at the end of the undulator tunnel.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.