[Paper Review] Coupled Tank Non-linear System; Modeling and Level Control using PID and Fuzzy Logic Techniques
This paper presents a nonlinear mathematical model of a coupled-tank system and evaluates both PID and fuzzy logic control strategies for liquid level regulation. Using MATLAB/Simulink, the authors demonstrate that fuzzy logic control achieves superior performance in stability and response time compared to conventional PID, particularly under nonlinear and dynamic conditions.
Liquid level control is very important in industrial field, where the liquid level is required, and to prevent overflows. The coupled-tank is a common system in industrial control processes. The system consists of two tanks connected together and the liquid flows between them. Tanks contain an inlet and outlet for each tank. The main principle of controlling this system is to maintain a constant level of liquid in both tanks when there are an inflow and outflow of liquid in each tank. To control liquid level in the coupled tank system, the mathematical model of the system had been derived and evaluated as a form of linear model. The mathematical model of coupled tank was developed to apply to both conventional and fuzzy control systems where the dynamic behavior of the system was considered. When the system had been designed the corresponding model was implemented in simulation by using Matlab and Simulink tools.
Motivation & Objective
- To develop an accurate nonlinear mathematical model of a coupled-tank system for industrial liquid level control applications.
- To investigate the effectiveness of conventional PID control in maintaining desired liquid levels under dynamic inflow and outflow conditions.
- To design and evaluate a fuzzy logic control system as an alternative to PID for improved robustness in nonlinear processes.
- To compare the performance of both control strategies using simulation in MATLAB/Simulink.
- To provide a benchmark for control techniques applicable to real-world industrial processes involving fluid dynamics and level regulation.
Proposed method
- Derivation of a nonlinear differential equation model based on mass balance principles for the coupled-tank system.
- Linearization of the nonlinear model around an operating point to facilitate PID controller design.
- Implementation of a conventional PID controller using proportional, integral, and derivative gains tuned via standard methods.
- Design of a fuzzy logic controller with input membership functions for level error and change in error, and output for valve actuation.
- Simulation of both control systems in MATLAB/Simulink to compare transient response, overshoot, settling time, and stability.
- Use of simulation tools to evaluate system behavior under varying inflow and outflow disturbances.
Experimental results
Research questions
- RQ1How does the nonlinear dynamic behavior of a coupled-tank system affect the performance of conventional PID control?
- RQ2To what extent does fuzzy logic control improve system stability and response time compared to PID in the presence of nonlinearity?
- RQ3What are the key differences in transient response characteristics (e.g., overshoot, settling time) between PID and fuzzy logic control in this system?
- RQ4How well does the linearized model represent the actual nonlinear system under varying operating conditions?
- RQ5Can fuzzy logic control effectively handle disturbances and maintain desired liquid levels without requiring precise system parameters?
Key findings
- The nonlinear model accurately captures the dynamic behavior of the coupled-tank system, especially under varying flow conditions.
- PID control exhibits significant overshoot and longer settling times when subjected to disturbances or changes in operating point.
- Fuzzy logic control demonstrates faster response, reduced overshoot, and improved stability across multiple operating conditions.
- The fuzzy logic controller maintains desired liquid levels more effectively than PID, particularly in the presence of nonlinearity and uncertainty.
- Simulation results confirm that fuzzy logic control outperforms PID in terms of robustness and transient response, validating its suitability for industrial applications.
- The linearized model provides a reasonable approximation for PID design but fails to fully represent system dynamics under large deviations.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.