Skip to main content
QUICK REVIEW

[Paper Review] CytoCrowd: A Multi-Annotator Benchmark Dataset for Cytology Image Analysis

Yonghao Si, Xingyuan Zeng|arXiv (Cornell University)|Feb 6, 2026
AI in cancer detectionComputer Science0 citations
TL;DR

CytoCrowd provides 446 high-resolution cytology images with raw annotations from four pathologists and a senior expert gold standard, enabling both standard CV evaluation and annotation-aggregation research.

ABSTRACT

High-quality annotated datasets are crucial for advancing machine learning in medical image analysis. However, a critical gap exists: most datasets either offer a single, clean ground truth, which hides real-world expert disagreement, or they provide multiple annotations without a separate gold standard for objective evaluation. To bridge this gap, we introduce CytoCrowd, a new public benchmark for cytology analysis. The dataset features 446 high-resolution images, each with two key components: (1) raw, conflicting annotations from four independent pathologists, and (2) a separate, high-quality gold-standard ground truth established by a senior expert. This dual structure makes CytoCrowd a versatile resource. It serves as a benchmark for standard computer vision tasks, such as object detection and classification, using the ground truth. Simultaneously, it provides a realistic testbed for evaluating annotation aggregation algorithms that must resolve expert disagreements. We provide comprehensive baseline results for both tasks. Our experiments demonstrate the challenges presented by CytoCrowd and establish its value as a resource for developing the next generation of models for medical image analysis.

Motivation & Objective

  • Provide a public cytology dataset with both raw expert disagreements and a gold-standard ground truth.
  • Enable evaluation of object detection, classification, and segmentation models using a definitive GT.
  • Offer a testbed for annotation aggregation algorithms to resolve expert disagreements.
  • Support baseline benchmarking for two tasks: computer vision and annotation aggregation.

Proposed method

  • Annotate 446 high-resolution cytology images with 14,579 raw ROIs by four board-certified pathologists using a 34-class taxonomy.
  • Create a senior expert-derived gold-standard GT with 6,402 objects by consolidating all annotations.
  • Define two tasks: (1) medical object detection/classification using the gold GT; (2) annotation aggregation to fuse conflicting annotations into a single result.
  • Evaluate using IoU-based localization with 0.5 threshold, reporting gold GT-based classification accuracy on correctly localized objects.
  • Provide baseline results for aggregation methods (MV, D&S, CATD, PM, LFC, ZenCrowd) and learning-based CV models (DeepEdit, Anytime, Qwen-VL-MAX, Qwen2.5-VL-72B).
  • Discuss dataset statistics and inter-annotator disagreement metrics (average pairwise IoU, percentage of objects identified by all four vs. by a single expert).
Figure 1. Raw expert annotations (left) vs. the final gold-standard ground truth (right) on a sample image from CytoCrowd.
Figure 1. Raw expert annotations (left) vs. the final gold-standard ground truth (right) on a sample image from CytoCrowd.

Experimental results

Research questions

  • RQ1How do raw multi-expert annotations compare to a senior-verified gold standard in cytology images?
  • RQ2How effective are standard annotation-aggregation methods on expert-disagreement data in cytology?
  • RQ3What is the performance gap between general vision-language models and specialized segmentation models on cytology tasks?
  • RQ4Can the CytoCrowd benchmark support robust evaluation of object detection/classification models using a definitive GT?

Key findings

  • Majority Voting achieves highest aggregation accuracy (0.903) among tested methods.
  • Dawid & Skene achieves 0.893 accuracy, close to MV.
  • Other aggregation baselines range from 0.855 to 0.883, indicating limited gains over MV in this expert dataset.
  • Qwen-VL-MAX and Qwen2.5-VL-72B perform poorly (accuracy < 0.45) on cytology tasks without specialized fine-tuning.
  • DeepEdit and Anytime achieve higher CV accuracies (0.899 and 0.878 respectively) compared to VLMs on this domain.
  • CytoCrowd reveals a high annotation burden (14,579 raw ROI annotations for 6,402 GT objects) and notable inter-annotator variability (average pairwise IoU 0.664).

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.