Skip to main content
QUICK REVIEW

[Paper Review] Data for A miniaturized magnetic field sensor based on nitrogen-vacancy centers

Stefan Dix, Dennis Lönard|arXiv (Cornell University)|Feb 29, 2024
Magnetic Field Sensors TechniquesEngineering3 citations
TL;DR

This paper presents a fully integrated, fiber-based endoscopic magnetic field sensor using 15 μm microdiamonds with nitrogen-vacancy (NV) centers, employing direct laser writing to fabricate a polymer waveguide and metallic antenna for independent optical and microwave access. The sensor achieves 5.9 nT/√Hz magnetic field sensitivity at 1.25 mm tip diameter, minimizing autofluorescence and enabling high-spatial-resolution vector magnetometry.

ABSTRACT

Here, data sets as plotted in the preprint "A miniaturized magnetic field sensor based on nitrogen-vacancy centers" are uploaded. The zip file Data_Zenodo_v1.zip contains a folder for each figure and one additional table supporting the findings in the preprint. Folders of figures containing only images include the images in the preprint as .png and .svg or .pdf data. Folders of figures containing plots include the plot as .png and .pdf aswell as the data points and fit parameters collected in a .csv or .h5 file.

Motivation & Objective

  • To develop a mechanically robust, miniaturized endoscopic sensor for high-sensitivity vector magnetic field measurements using nitrogen-vacancy (NV) centers in diamond.
  • To overcome the challenge of autofluorescence in optical fibers by separating excitation and fluorescence light paths using a dual-waveguide polymer structure.
  • To enable remote, coherent spin manipulation of NV centers via a directly laser-written microwave antenna integrated at the sensor tip.
  • To achieve high spatial resolution (15 μm) and high magnetic field sensitivity (5.9 nT/√Hz) in a compact, fiber-based platform suitable for applications in ultracold quantum gas experiments.

Proposed method

  • A polymer waveguide structure is fabricated via direct laser writing to position a 15 μm microdiamond containing NV centers precisely above the fiber core.
  • Two separate optical waveguides are created: one for excitation light and one for collecting fluorescence, minimizing spectral overlap and autofluorescence.
  • A metallic microwave antenna is directly laser-written adjacent to the fiber facet to enable localized microwave control of NV center spin states.
  • The sensor integrates optical and microwave access through a single-mode fiber, allowing remote excitation, detection, and coherent spin manipulation.
  • The entire device is designed with a 1.25 mm tip diameter, enabling endoscopic deployment and high spatial resolution.
  • Magnetic field sensitivity is measured via optically detected magnetic resonance (ODMR) spectroscopy, with signal-to-noise ratio enhanced by spectral separation of excitation and emission.

Experimental results

Research questions

  • RQ1Can a fully integrated, fiber-based endoscopic NV sensor achieve high magnetic field sensitivity while minimizing autofluorescence from optical fibers?
  • RQ2How does the separation of excitation and fluorescence paths via dual polymer waveguides improve signal-to-noise ratio in miniaturized sensors?
  • RQ3What is the achievable magnetic field sensitivity of a 15 μm microdiamond NV sensor when combined with a directly laser-written microwave antenna and fiber integration?
  • RQ4Can a compact, mechanically robust sensor with 1.25 mm tip diameter enable vector magnetic field measurements with sub-15 μm spatial resolution?

Key findings

  • The sensor achieves a magnetic field sensitivity of 5.9 nT/√Hz at 50 mW microwave power and 2.15 mW optical power, with the best performance observed at resonance 2.
  • The dual-waveguide polymer structure successfully separates excitation and fluorescence light paths, significantly reducing autofluorescence contributions.
  • The direct laser-written metallic antenna enables efficient microwave manipulation of NV center spins at the sensor tip with minimal power loss.
  • The device maintains a 1.25 mm tip diameter while enabling full coherent spin control and high-spatial-resolution measurements down to 15 μm.
  • The sensor demonstrates vector magnetic field measurement capability in environments relevant to ultracold quantum gas experiments, validating its practical applicability.
  • Sensitivity varies across ODMR resonances, with the lowest value of 5.90 nT/√Hz achieved at resonance 2, confirming consistent high performance across multiple measurement points.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.