Skip to main content
QUICK REVIEW

[Paper Review] Decoupling Spatio-Temporal Dynamics: Microvibration Imaging Using Coherent Detection Ghost Imaging Lidar

Shuang Liu, Jinquan Qi|Figshare|Feb 27, 2026
Advanced Optical Sensing TechnologiesPhysics and Astronomy0 citations
TL;DR

The paper introduces a Coherent Detection-Ghost Imaging (CD-GI) lidar that decouples spatial and micro-Doppler dynamics via a frequency-channel self-calibration, enabling full-field microvibration imaging of extended targets.

ABSTRACT

Imaging the full-field microvibration of extended targets remains a formidable challenge for conventional remote sensing. Traditional array-based sensors are often severely constrained by data throughput and sensitivity limits when scaling to high spatial resolutions, while point-scanning interferometric systems lack the instantaneous full-field capability required to capture transient, spatially coupled vibration modes. To overcome these limitations, we propose a Coherent Detection-Ghost Imaging (CD-GI) framework that synergizes the spatial multiplexing capability of single-pixel imaging with the high-dimensional sensitivity of coherent detection. We establish a comprehensive mathematical model that describes the coupling mechanism of the target's spatial distribution and temporal micro-dynamics within a 1D bucket detector signal. To resolve the resulting inverse problem, we develop a frequency-channel self-calibration scheme. This approach effectively decouples the micro-Doppler signatures from spatial speckle patterns without requiring prior knowledge of the vibration frequency. Experimental results demonstrate that our system successfully reconstructs the spatially resolved microvibration patterns of adjacent targets with a frequency difference as small as 1 Hz, achieving sub-wavelength vibration sensitivity. This work bridges the gap between computational imaging and coherent metrology, offering a robust solution for non-invasive, high-precision structural health monitoring.

Motivation & Objective

  • Motivate non-invasive, high-resolution microvibration imaging for structural health monitoring and MEMS characterization.
  • Develop a spatio-temporal coupling model that captures how target vibrations encode into a 1D bucket signal.
  • Create a frequency-channel self-calibration method to decouple vibration signatures from spatial speckle without prior frequency knowledge.
  • Demonstrate full-field microvibration reconstruction and dynamic visualization of adjacent targets with small frequency differences.

Proposed method

  • Propose a Mach-Zehnder CD-GI lidar architecture with a DMD-based spatial modulation and a balanced detector for coherent detection.
  • Derive a signal model showing how target spatial distribution and temporal micro-dynamics couple into the bucket detector signal.
  • Introduce a frequency-channel self-calibration algorithm to synchronize random vibration phases across pulses without knowing the vibration frequency.
  • Apply time-frequency analysis (STFT) to the coherently integrated signal to extract dominant scatterer micro-Doppler trajectories.
  • Use PSO to track dominant scatterer micro-Doppler parameters (amplitude, frequency, initial phase) and reconstruct dynamic vibration frames via second-order correlation (ghost imaging).
  • Provide a phase-scanning approach to visualize the full vibration dynamics over time.

Experimental results

Research questions

  • RQ1Can the proposed CD-GI framework decouple spatio-temporal dynamics in a single-pixel, coherent-detection setup without prior vibration frequency knowledge?
  • RQ2What is the frequency selectivity and sensing limit when resolving adjacent vibrating targets with small frequency differences?
  • RQ3How accurately can the dominant scatterer’s vibration parameters (amplitude, frequency, initial phase) be estimated and used to reconstruct dynamic vibration frames?
  • RQ4Can the method reconstruct spatially resolved microvibration modes for non-cooperative targets at sub-wavelength scales?

Key findings

  • The method can resolve spatially resolved microvibration patterns of adjacent targets with a frequency difference as small as 1 Hz.
  • Experiments at 65 meters demonstrate reconstruction of vibration modes using the CD-GI lidar in a rooftop setting.
  • The approach achieves sub-wavelength vibration sensitivity by decoupling micro-Doppler signatures from speckle patterns through frequency-channel calibration.
  • The framework provides 3D and 2D reconstructions of dominant scatterers and enables dynamic visualization of vibration modes via phase scanning.
  • PSO-based tracking identifies optimal vibration parameters and enables coherent integration across pulses for high-SNR imaging.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.