Skip to main content
QUICK REVIEW

[Paper Review] Deep Features for Tissue-Fold Detection in Histopathology Images

Morteza Babaie, Hamid R. Tizhoosh|arXiv (Cornell University)|Mar 17, 2019
AI in cancer detectionComputer Science22 references5 citations
TL;DR

This paper proposes a deep learning-based method for detecting tissue folds in whole slide images (WSIs) using pre-trained convolutional neural networks (CNNs) as feature extractors and an SVM classifier. Using 2.5mm × 2.5mm H&E-stained patches at 20x magnification, DenseNet-201 with SVM achieved 96.3% accuracy (97.2% with data augmentation), and generalized to unseen NIH WSIs with 81% patch-wise accuracy, demonstrating strong potential for clinical quality control.

ABSTRACT

Whole slide imaging (WSI) refers to the digitization of a tissue specimen which enables pathologists to explore high-resolution images on a monitor rather than through a microscope. The formation of tissue folds occur during tissue processing. Their presence may not only cause out-of-focus digitization but can also negatively affect the diagnosis in some cases. In this paper, we have compared five pre-trained convolutional neural networks (CNNs) of different depths as feature extractors to characterize tissue folds. We have also explored common classifiers to discriminate folded tissue against the normal tissue in hematoxylin and eosin (H\&E) stained biopsy samples. In our experiments, we manually select the folded area in roughly 2.5mm $ imes$ 2.5mm patches at $20$x magnification level as the training data. The ``DenseNet'' with 201 layers alongside an SVM classifier outperformed all other configurations. Based on the leave-one-out validation strategy, we achieved $96.3\%$ accuracy, whereas with augmentation the accuracy increased to $97.2\%$. We have tested the generalization of our method with five unseen WSIs from the NIH (National Cancer Institute) dataset. The accuracy for patch-wise detection was $81\%$. One folded patch within an image suffices to flag the entire specimen for visual inspection.

Motivation & Objective

  • To address the challenge of tissue folds in whole slide imaging (WSI), which can impair diagnosis and scanning quality.
  • To develop a robust, automated method for detecting folded tissue in H&E-stained biopsy samples using deep features.
  • To evaluate the generalization capability of deep features across different WSIs from external datasets like NIH.
  • To compare multiple pre-trained CNNs and classifiers for optimal performance in tissue-fold detection.

Proposed method

  • Pre-trained CNNs (VGG16, GoogleNet, InceptionV3, ResNet101, DenseNet201) were used as feature extractors on 2.5mm × 2.5mm patches from WSIs.
  • Features were extracted from the final fully connected layer of each network, followed by L2 normalization.
  • A support vector machine (SVM) with quadratic kernel was used as the classifier, trained on manually labeled folded and normal tissue patches.
  • Data augmentation (rotation, flipping) was applied to improve generalization and reduce false negatives.
  • The model was evaluated using leave-one-out cross-validation and tested on five unseen WSIs from the NIH dataset using varying patch sizes (1500×1500 to 4000×4000).
  • Patch-wise classification was performed without overlap, and detection of at least one fold was sufficient to flag an entire WSI for visual inspection.

Experimental results

Research questions

  • RQ1Which pre-trained CNN architecture yields the best deep features for distinguishing folded from normal tissue in H&E-stained histopathology images?
  • RQ2How does data augmentation affect the performance and robustness of the tissue-fold detection model?
  • RQ3Can a model trained on a limited, manually curated dataset generalize effectively to unseen whole slide images from different sources?
  • RQ4What is the impact of patch size and windowing strategy on detection accuracy in real-world WSI evaluation?
  • RQ5Is the detection of a single folded patch sufficient to flag an entire WSI for clinical review?

Key findings

  • DenseNet-201 with an SVM classifier achieved the highest accuracy of 96.3% using leave-one-out cross-validation on the training dataset.
  • With data augmentation, the model’s accuracy improved to 97.2%, and the false negative rate decreased from 2.6% to 2.1%.
  • On five unseen WSIs from the NIH dataset, the model achieved 81% patch-wise detection accuracy, indicating acceptable generalization to new data.
  • The false positive rate remained unchanged after augmentation, suggesting that the model’s specificity was not significantly altered.
  • False negatives were primarily due to partial fold coverage across patch boundaries or mismatched training patch sizes (5000×5000) versus test window sizes (1500×1500).
  • The results indicate that detecting even one folded patch is sufficient to flag an entire WSI for visual inspection, supporting clinical utility.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.