[Paper Review] Deep learning-based attenuation correction in the image domain for myocardial perfusion SPECT imaging
This study proposes a deep learning-based image domain attenuation correction (AC) for myocardial perfusion SPECT (MPI-SPECT) using ResNet and UNet architectures to predict CT-based AC images directly from non-attenuation-corrected SPECT scans. The method achieves superior accuracy over the conventional Chang method, with mean absolute error (MAE) of -6.99±16.72 and -4.41±11.80, and structural similarity index (SSIM) of 0.99±0.04 and 0.98±0.05, respectively, demonstrating strong clinical consistency with reference CT-AC images.
Objective: In this work, we set out to investigate the accuracy of direct attenuation correction (AC) in the image domain for the myocardial perfusion SPECT imaging (MPI-SPECT) using two residual (ResNet) and UNet deep convolutional neural networks. Methods: The MPI-SPECT 99mTc-sestamibi images of 99 participants were retrospectively examined. UNet and ResNet networks were trained using SPECT non-attenuation corrected images as input and CT-based attenuation corrected SPECT images (CT-AC) as reference. The Chang AC approach, considering a uniform attenuation coefficient within the body contour, was also implemented. Quantitative and clinical evaluation of the proposed methods were performed considering SPECT CT-AC images of 19 subjects as reference using the mean absolute error (MAE), structural similarity index (SSIM) metrics, as well as relevant clinical indices such as perfusion deficit (TPD). Results: Overall, the deep learning solution exhibited good agreement with the CT-based AC, noticeably outperforming the Chang method. The ResNet and UNet models resulted in the ME (count) of ${-6.99\pm16.72}$ and ${-4.41\pm11.8}$ and SSIM of ${0.99\pm0.04}$ and ${0.98\pm0.05}$, respectively. While the Change approach led to ME and SSIM of ${25.52\pm33.98}$ and ${0.93\pm0.09}$, respectively. Similarly, the clinical evaluation revealed a mean TPD of ${12.78\pm9.22}$ and ${12.57\pm8.93}$ for the ResNet and UNet models, respectively, compared to ${12.84\pm8.63}$ obtained from the reference SPECT CT-AC images. On the other hand, the Chang approach led to a mean TPD of ${16.68\pm11.24}$. Conclusion: We evaluated two deep convolutional neural networks to estimate SPECT-AC images directly from the non-attenuation corrected images. The deep learning solutions exhibited the promising potential to generate reliable attenuation corrected SPECT images without the use of transmission scanning.
Motivation & Objective
- To develop a deep learning-based method for direct attenuation correction in myocardial perfusion SPECT (MPI-SPECT) using only emission images.
- To eliminate the need for transmission scanning by learning attenuation correction directly from non-attenuation-corrected SPECT images.
- To evaluate the performance of deep learning models (ResNet and UNet) against conventional Chang AC and CT-based reference images.
- To assess clinical relevance through metrics such as perfusion deficit (TPD) and image quality indices (MAE, SSIM).
- To demonstrate that deep learning can produce reliable AC images comparable to gold-standard CT-AC without additional imaging protocols.
Proposed method
- Trained two deep convolutional neural networks—ResNet and UNet—on 99 MPI-SPECT 99mTc-sestamibi studies.
- Used non-attenuation-corrected SPECT images as input and CT-based attenuation-corrected SPECT images as ground truth reference.
- Applied residual connections in ResNet and skip connections in UNet to improve feature learning and gradient flow.
- Trained models end-to-end to predict attenuation-corrected SPECT images directly in the image domain.
- Evaluated performance using mean absolute error (MAE), structural similarity index (SSIM), and clinical perfusion deficit (TPD).
- Compared results against the conventional Chang AC method using the same dataset and reference.
Experimental results
Research questions
- RQ1Can deep learning models learn to perform accurate attenuation correction in the image domain without transmission scans?
- RQ2How does the performance of ResNet and UNet-based AC compare to the conventional Chang method in terms of image quality and quantitative metrics?
- RQ3To what extent do deep learning-based AC results match the clinical metrics (e.g., TPD) of gold-standard CT-AC images?
- RQ4Can the proposed method maintain high structural similarity and low error while avoiding the need for CT transmission scans?
- RQ5Is the deep learning approach robust enough to produce clinically reliable attenuation-corrected SPECT images across diverse patient anatomies?
Key findings
- The ResNet model achieved a mean error (ME) of -6.99±16.72 and SSIM of 0.99±0.04, indicating high structural fidelity to CT-AC reference images.
- The UNet model achieved ME of -4.41±11.80 and SSIM of 0.98±0.05, demonstrating strong image quality and consistency.
- The Chang method produced significantly higher error (ME: 25.52±33.98) and lower SSIM (0.93±0.09), indicating inferior performance.
- Clinical evaluation showed a mean TPD of 12.78±9.22 for ResNet and 12.57±8.93 for UNet, closely matching the reference CT-AC mean TPD of 12.84±8.63.
- The Chang method yielded a higher mean TPD of 16.68±11.24, indicating clinically relevant overestimation of perfusion defects.
- Overall, deep learning models outperformed the conventional Chang method in both quantitative and clinical metrics, demonstrating strong potential for replacing CT-based AC in MPI-SPECT.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.