Skip to main content
QUICK REVIEW

[Paper Review] Deep Modeling and Interpretation for Bladder Cancer Classification

Ahmad Chaddad, Yihang Wu|arXiv (Cornell University)|Feb 10, 2026
AI in cancer detectionComputer Science0 citations
TL;DR

The paper evaluates 13 deep models (CNNs and ViTs) for bladder cancer classification on a multicenter dataset, analyzes calibration and interpretability with GradCAM++, and examines test-time augmentation effects.

ABSTRACT

Deep models based on vision transformer (ViT) and convolutional neural network (CNN) have demonstrated remarkable performance on natural datasets. However, these models may not be similar in medical imaging, where abnormal regions cover only a small portion of the image. This challenge motivates this study to investigate the latest deep models for bladder cancer classification tasks. We propose the following to evaluate these deep models: 1) standard classification using 13 models (four CNNs and eight transormer-based models), 2) calibration analysis to examine if these models are well calibrated for bladder cancer classification, and 3) we use GradCAM++ to evaluate the interpretability of these models for clinical diagnosis. We simulate $\sim 300$ experiments on a publicly multicenter bladder cancer dataset, and the experimental results demonstrate that the ConvNext series indicate limited generalization ability to classify bladder cancer images (e.g., $\sim 60\%$ accuracy). In addition, ViTs show better calibration effects compared to ConvNext and swin transformer series. We also involve test time augmentation to improve the models interpretability. Finally, no model provides a one-size-fits-all solution for a feasible interpretable model. ConvNext series are suitable for in-distribution samples, while ViT and its variants are suitable for interpreting out-of-distribution samples.

Motivation & Objective

  • Assess the performance of 13 deep models (four ConvNeXt, eight ViT-based, and Swin Transformer variants) on a multicenter bladder cancer dataset.
  • Evaluate model calibration using expected calibration error (ECE) and reliability plots without extra calibration techniques.
  • Assess model interpretability with GradCAM++ in both in-distribution and out-of-distribution settings.
  • Investigate the impact of test-time augmentation (TTA) on model interpretability and heatmap quality.
  • Compare optimization strategies across five optimizers to understand their influence on performance and calibration.

Proposed method

  • Use a unified preprocessing and training pipeline across models with 224x224 input size and z-score normalization.
  • Train 13 models across five optimizers (SGD, Adam, AdamW, Adagrad, Adadelta) with a common set of hyperparameters.
  • Evaluate classification metrics: Accuracy (ACC), Balanced Accuracy (BACC), Precision, Recall, F1, and AVG.
  • Compute calibration metrics: Expected Calibration Error (ECE) and reliability plots.
  • Use GradCAM++ to visualize model attention for in-distribution and out-of-distribution data, with and without test-time augmentation (TTA).
  • Conduct four-fold cross-center partitions on a multicenter bladder dataset (C1–C4) for training/validation/testing.

Experimental results

Research questions

  • RQ1Which deep models (CNN vs ViT vs Swin Transformer) offer the best in-distribution and out-of-distribution performance on multicenter bladder cancer data?
  • RQ2How well are these models calibrated for bladder cancer classification without additional calibration techniques?
  • RQ3Do GradCAM++ heatmaps provide reliable interpretability across ID and OOD settings, and does TTA improve explainability?
  • RQ4How do different optimizers affect performance, calibration, and execution time across the model families?
  • RQ5Can domain shifts between centers be mitigated or revealed through calibration and interpretability analyses?

Key findings

  • ConvNext models show limited generalization on test data, with about 60% accuracy in some cases.
  • ViT-based models exhibit better calibration than ConvNeXt and Swin Transformer series, though not uniformly across centers.
  • ViT variants like ViT_h_14 demonstrate relatively better calibration results compared to ConvNext models.
  • Swin Transformer models generally show poorer calibration (high ECE) despite competitive AVG metrics in some folds.
  • GradCAM++ heatmaps indicate ConvNext models often provide more reliable ID explanations, while ViT models yield better OOD attention in some centers.
  • Test-time augmentation improves interpretability for some models, particularly transforming attention patterns in ID and OOD settings; overall benefits vary by model.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.