TL;DR

This paper proposes a model-agnostic method that uses a recurrent neural network with visual attention to generate radiologist-quality, natural language explanations for deep learning-based medical image classification. It demonstrates that clinicians prefer these text explanations over saliency maps alone, and especially when combined with visual explanations, achieving high accuracy in describing fracture location (90%) and character (98%) as rated by radiologists.

ABSTRACT

Current approaches to explaining the decisions of deep learning systems for medical tasks have focused on visualising the elements that have contributed to each decision. We argue that such approaches are not enough to "open the black box" of medical decision making systems because they are missing a key component that has been used as a standard communication tool between doctors for centuries: language. We propose a model-agnostic interpretability method that involves training a simple recurrent neural network model to produce descriptive sentences to clarify the decision of deep learning classifiers. We test our method on the task of detecting hip fractures from frontal pelvic x-rays. This process requires minimal additional labelling despite producing text containing elements that the original deep learning classification model was not specifically trained to detect. The experimental results show that: 1) the sentences produced by our method consistently contain the desired information, 2) the generated sentences are preferred by doctors compared to current tools that create saliency maps, and 3) the combination of visualisations and generated text is better than either alone.

Motivation & Objective

  • To address the clinical need for interpretable AI in medicine by generating human-style explanations that clinicians trust.
  • To overcome limitations of saliency maps by introducing natural language descriptions that convey diagnostic reasoning.
  • To develop a method that is model-agnostic and requires minimal additional labeling beyond existing diagnostic data.
  • To evaluate whether generated text explanations are preferred by radiologists over visual-only explanations.
  • To assess whether combining text and visual explanations improves diagnostic interpretability beyond either modality alone.

Proposed method

  • A recurrent neural network with visual attention is trained to generate descriptive sentences explaining the decisions of a pre-trained deep learning classifier.
  • The model is trained on a simplified, radiologist-annotated set of descriptive terms for hip fracture location and character, derived from original radiology reports.
  • The training data uses a constrained vocabulary of key anatomical and descriptive terms to ensure consistency and clinical relevance.
  • The method is applied to a large dataset of 50,363 frontal pelvic X-rays with 4,010 hip fractures, using a DenseNet classifier as the base model.
  • Saliency maps are generated using the SmoothGrad method for comparison with text explanations.
  • Explanations are evaluated via radiologist scoring of text quality and clinical preference in a comparative study.

Experimental results

Research questions

  • RQ1Can a simple recurrent neural network generate natural language explanations that are clinically meaningful and preferred by radiologists?
  • RQ2How does the quality of generated text compare to original radiology reports in describing fracture location and character?
  • RQ3Do clinicians prefer text-based explanations over saliency maps for AI decisions?
  • RQ4Is a combination of text and visual explanations more effective than either alone?
  • RQ5Can this method be applied to any deep learning classifier without retraining, making it model-agnostic?

Key findings

  • The generated sentences achieved 90% accuracy in describing the correct anatomical location of hip fractures, compared to 99% in original radiology reports.
  • The model achieved 98% accuracy in describing the character of fractures, significantly outperforming original reports, which were correct only 78% of the time.
  • Radiologists rated generated text explanations with an average score of 7.0 out of 10, significantly higher than saliency maps alone (4.4/10).
  • The combination of saliency maps and generated text received the highest average score (8.8/10), indicating strong preference for multimodal explanations.
  • The method is model-agnostic and requires minimal additional labeling, leveraging existing diagnostic labels for both classification and explanation.
  • The approach successfully distills complex model decisions into concise, human-readable descriptions that align with clinical reasoning.