Skip to main content
QUICK REVIEW

[Paper Review] Determination of Reference Scales for Wilson Gauge Action from Yang--Mills Gradient Flow

Masayuki Asakawa, Takumi Iritani|arXiv (Cornell University)|Mar 23, 2015
Quantum Chromodynamics and Particle InteractionsPhysics and Astronomy21 references23 citations
TL;DR

This paper determines the lattice spacing $a$ in terms of the bare coupling $\beta$ for SU(3) Yang-Mills theory with the Wilson gauge action using the Yang-Mills gradient flow. By measuring the dimensionless observable $t^2\langle E(t)\rangle$ and fixing its value at a specific flow time, the authors achieve a parametrization of $a(\beta)$ with sub-0.5% accuracy over $6.3 \leq \beta \leq 7.5$, significantly reducing discretization and finite-volume errors through fine lattices and large volumes.

ABSTRACT

A parametrization of the lattice spacing ($a$) in terms of the bare coupling ($β$) for the SU(3) Yang--Mills theory with the Wilson gauge action is given in a wide range of~$β$. The Yang--Mills gradient flow with respect to the flow time~$t$ for the dimensionless observable, $t\frac{d}{dt}t^2\langle E(t) angle$, is utilized to determine the parametrization. With fine lattice spacings ($6.3\leβ\le7.5$) and large lattice volumes ($N_{ m s}=64$--$128$), the discretization and finite-volume errors are significantly reduced to the same level as the statistical error.

Motivation & Objective

  • To determine the lattice spacing $a$ in terms of the bare coupling $\beta$ for SU(3) Yang-Mills theory with the Wilson gauge action over a wide range of $\beta$.
  • To reduce discretization and finite-volume errors in scale setting by employing the Yang-Mills gradient flow and large lattice volumes ($N_s = 64$–$128$).
  • To provide a reference scale parametrization with sub-0.5% accuracy, enabling precise continuum extrapolation and thermodynamic studies.
  • To compare the gradient flow method with traditional methods like the string tension or Sommer scale, which require fitting the potential $V(r)$.

Proposed method

  • The Yang-Mills gradient flow is used to define a dimensionless observable $t^2\langle E(t)\rangle$, where $E(t)$ is the energy density of the gauge field evolved under the flow.
  • The flow time $t$ is chosen such that $t^2\langle E(t)\rangle = X$ for a fixed $X$, defining the reference scale $w_{0.4}$ as the flow time where this condition holds.
  • Numerical simulations are performed on lattices with $N_s = 64$ to $128$ and $\beta$ from 6.3 to 7.5, with the finest lattices using $128^4$ to suppress finite-volume effects.
  • Discretization and finite-volume effects are minimized by tuning $X$ so that these systematic errors are smaller than statistical errors.
  • The relation $a(\beta)$ is extracted via continuum extrapolation using $a^2/w_{0.4}^2$ as the variable, excluding the coarsest data point at $\beta=6.3$.
  • The $\overline{\text{MS}}$-scheme $\Lambda$-parameter is computed using tadpole-improved perturbation theory and Padé approximants, with systematic errors estimated via alternative methods.

Experimental results

Research questions

  • RQ1Can the Yang-Mills gradient flow be used to determine the lattice spacing $a(\beta)$ with sub-0.5% accuracy over a wide $\beta$ range?
  • RQ2How do discretization and finite-volume errors scale in the gradient flow method, and can they be reduced to the level of statistical errors?
  • RQ3What is the value of the $\overline{\text{MS}}$-scheme $\Lambda$-parameter in SU(3) Yang-Mills theory, and how does it compare to perturbative estimates?
  • RQ4Does the gradient flow method outperform traditional scale-setting methods like the string tension or Sommer scale in terms of systematic error control?

Key findings

  • The authors achieve a parametrization of $a(\beta)$ with a statistical error of less than 0.5% across $6.3 \leq \beta \leq 7.5$, significantly extending the range of previous studies.
  • The value of $w_{0.4}\Lambda_{\overline{\text{MS}}}$ in the continuum limit is determined to be $0.2388(5)(13)$, with the first error statistical and the second systematic.
  • Finite-volume effects are suppressed to the level of statistical errors by using $128^4$ lattices at $\beta = 7.4$ and $7.5$, and discretization errors are minimized by tuning the reference scale parameter $X$.
  • The method avoids the need for fitting the heavy-quark potential $V(r)$, reducing systematic uncertainties compared to traditional scale-setting approaches.
  • The continuum extrapolation of $w_{0.4}\Lambda_{\overline{\text{MS}}}$ using $a^2/w_{0.4}^2$ as the variable yields a stable linear fit, confirming the reliability of the result.
  • The use of Padé-improved perturbation theory in Method II yields a consistent result with the systematic error estimate, supporting the robustness of the final $\Lambda_{\overline{\text{MS}}}$ value.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.